Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care

Increasing numbers of people, particularly with type 1 diabetes (T1D), are using wearable technologies. That is, continuous subcutaneous insulin infusion (CSII) pumps, continuous glucose monitoring (CGM) systems, and hybrid closed-loop systems, which combine both these elements. Given over a quarter...

Descripción completa

Detalles Bibliográficos
Autores principales: Avari, Parizad, Lumb, Alistair, Flanagan, Daniel, Rayman, Gerry, Misra, Shivani, Dhatariya, Ketan, Choudhary, Pratik
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10210120/
https://www.ncbi.nlm.nih.gov/pubmed/36444418
http://dx.doi.org/10.1177/19322968221137338
_version_ 1785047001152356352
author Avari, Parizad
Lumb, Alistair
Flanagan, Daniel
Rayman, Gerry
Misra, Shivani
Dhatariya, Ketan
Choudhary, Pratik
author_facet Avari, Parizad
Lumb, Alistair
Flanagan, Daniel
Rayman, Gerry
Misra, Shivani
Dhatariya, Ketan
Choudhary, Pratik
author_sort Avari, Parizad
collection PubMed
description Increasing numbers of people, particularly with type 1 diabetes (T1D), are using wearable technologies. That is, continuous subcutaneous insulin infusion (CSII) pumps, continuous glucose monitoring (CGM) systems, and hybrid closed-loop systems, which combine both these elements. Given over a quarter of all people admitted to hospital have diabetes, there is a need for clinical guidelines for when people using them are admitted to hospital. The Joint British Diabetes Societies for Inpatient Care (JBDS-IP) provide a scoping review and summary of guidelines on the use of diabetes technology in people with diabetes admitted to hospital. JBDS-IP advocates enabling people who can self-manage and use their own diabetes technology to continue doing so as they would do out of hospital. Whilst people with diabetes are recommended to achieve a target of 70% time within range (3.9-10.0 mmol/L [70-180 mg/dL]), this can be very difficult to achieve whilst unwell. We therefore recommend targeting hypoglycemia prevention as a priority, keeping time below 3.9 mmol/L (70 mg/dL) at < 1%, being aware of looming hypoglycemia if glucose is between 4.0 and 5.9 mmol/L (72-106 mg/dL), and consider intervening, particularly if there is a downward CGM trend arrow. Health care organizations need clear local policies and guidance to support individuals using diabetes technologies, and ensure the relevant workforce is capable and skilled enough to ensure their safe use within the hospital setting. The current set of guidelines is divided into two parts. Part 1, which follows below, outlines the guidance for use of CGM in hospital. The second part outlines guidance for use of CSII and hybrid closed-loop in hospital.
format Online
Article
Text
id pubmed-10210120
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-102101202023-05-26 Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care Avari, Parizad Lumb, Alistair Flanagan, Daniel Rayman, Gerry Misra, Shivani Dhatariya, Ketan Choudhary, Pratik J Diabetes Sci Technol Special Section: Diabetes Technology in the Hospital Increasing numbers of people, particularly with type 1 diabetes (T1D), are using wearable technologies. That is, continuous subcutaneous insulin infusion (CSII) pumps, continuous glucose monitoring (CGM) systems, and hybrid closed-loop systems, which combine both these elements. Given over a quarter of all people admitted to hospital have diabetes, there is a need for clinical guidelines for when people using them are admitted to hospital. The Joint British Diabetes Societies for Inpatient Care (JBDS-IP) provide a scoping review and summary of guidelines on the use of diabetes technology in people with diabetes admitted to hospital. JBDS-IP advocates enabling people who can self-manage and use their own diabetes technology to continue doing so as they would do out of hospital. Whilst people with diabetes are recommended to achieve a target of 70% time within range (3.9-10.0 mmol/L [70-180 mg/dL]), this can be very difficult to achieve whilst unwell. We therefore recommend targeting hypoglycemia prevention as a priority, keeping time below 3.9 mmol/L (70 mg/dL) at < 1%, being aware of looming hypoglycemia if glucose is between 4.0 and 5.9 mmol/L (72-106 mg/dL), and consider intervening, particularly if there is a downward CGM trend arrow. Health care organizations need clear local policies and guidance to support individuals using diabetes technologies, and ensure the relevant workforce is capable and skilled enough to ensure their safe use within the hospital setting. The current set of guidelines is divided into two parts. Part 1, which follows below, outlines the guidance for use of CGM in hospital. The second part outlines guidance for use of CSII and hybrid closed-loop in hospital. SAGE Publications 2022-11-28 /pmc/articles/PMC10210120/ /pubmed/36444418 http://dx.doi.org/10.1177/19322968221137338 Text en © 2022 Diabetes Technology Society https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Special Section: Diabetes Technology in the Hospital
Avari, Parizad
Lumb, Alistair
Flanagan, Daniel
Rayman, Gerry
Misra, Shivani
Dhatariya, Ketan
Choudhary, Pratik
Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
title Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
title_full Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
title_fullStr Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
title_full_unstemmed Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
title_short Continuous Glucose Monitoring Within Hospital: A Scoping Review and Summary of Guidelines From the Joint British Diabetes Societies for Inpatient Care
title_sort continuous glucose monitoring within hospital: a scoping review and summary of guidelines from the joint british diabetes societies for inpatient care
topic Special Section: Diabetes Technology in the Hospital
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10210120/
https://www.ncbi.nlm.nih.gov/pubmed/36444418
http://dx.doi.org/10.1177/19322968221137338
work_keys_str_mv AT avariparizad continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare
AT lumbalistair continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare
AT flanagandaniel continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare
AT raymangerry continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare
AT misrashivani continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare
AT dhatariyaketan continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare
AT choudharypratik continuousglucosemonitoringwithinhospitalascopingreviewandsummaryofguidelinesfromthejointbritishdiabetessocietiesforinpatientcare