Cargando…

Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products

A sampling chamber was developed for emission testing of diisocyanates, methylene diphenyl diisocyanate (MDI), toluene diisocyanate (TDI), and corresponding diamines, methylene diphenyl diamine (MDA), and toluene diamine (TDA) from polyurethane (PU) product surfaces. In addition, a methodology for v...

Descripción completa

Detalles Bibliográficos
Autor principal: Karlsson, Daniel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10210200/
https://www.ncbi.nlm.nih.gov/pubmed/37134012
http://dx.doi.org/10.1177/07482337231172811
_version_ 1785047018818764800
author Karlsson, Daniel
author_facet Karlsson, Daniel
author_sort Karlsson, Daniel
collection PubMed
description A sampling chamber was developed for emission testing of diisocyanates, methylene diphenyl diisocyanate (MDI), toluene diisocyanate (TDI), and corresponding diamines, methylene diphenyl diamine (MDA), and toluene diamine (TDA) from polyurethane (PU) product surfaces. In addition, a methodology for validation of the sampling chamber was presented, based on the introduction of generated standard atmospheres of the different diisocyanates and diamines to the sampling chamber system. Sampling of diisocyanates and diamines was performed on a circular glass fiber filter (150 mm diameter) impregnated with dihexyl amine (DHA) and acetic acid (AA) positioned inside a cylindrical stainless steel sampling chamber. The diisocyanates were immediately derivatized to DHA derivatives, and the amines were derivatized in a subsequent work-up procedure with ethyl chloroformate (ECF). The design of the sampling chamber and the presented methodology allowed for simultaneous sampling and analysis of diisocyanates and diamines of emission from a large surface area with minimal interior wall interaction in the sampling chamber. Performance characteristics of the sampling chamber for different sampling times and air humidity were obtained by determining collected amounts of the diisocyanates and diamines in the different parts of the sampling chamber. The repeatability of the collected amount on the impregnated filters in the sampling chamber was 15% with an overall recovery for 8 h of sampling in the range of 61% to 96%. The performance of the sampling chamber was not affected by air humidity (5%–75% RH), and no breakthrough during sampling was observed. LC-MS/MS determinations allowed for emission testing of diisocyanates and diamines on product surfaces as low as 10–30 ng m(−2) h(−1).
format Online
Article
Text
id pubmed-10210200
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-102102002023-05-26 Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products Karlsson, Daniel Toxicol Ind Health Articles A sampling chamber was developed for emission testing of diisocyanates, methylene diphenyl diisocyanate (MDI), toluene diisocyanate (TDI), and corresponding diamines, methylene diphenyl diamine (MDA), and toluene diamine (TDA) from polyurethane (PU) product surfaces. In addition, a methodology for validation of the sampling chamber was presented, based on the introduction of generated standard atmospheres of the different diisocyanates and diamines to the sampling chamber system. Sampling of diisocyanates and diamines was performed on a circular glass fiber filter (150 mm diameter) impregnated with dihexyl amine (DHA) and acetic acid (AA) positioned inside a cylindrical stainless steel sampling chamber. The diisocyanates were immediately derivatized to DHA derivatives, and the amines were derivatized in a subsequent work-up procedure with ethyl chloroformate (ECF). The design of the sampling chamber and the presented methodology allowed for simultaneous sampling and analysis of diisocyanates and diamines of emission from a large surface area with minimal interior wall interaction in the sampling chamber. Performance characteristics of the sampling chamber for different sampling times and air humidity were obtained by determining collected amounts of the diisocyanates and diamines in the different parts of the sampling chamber. The repeatability of the collected amount on the impregnated filters in the sampling chamber was 15% with an overall recovery for 8 h of sampling in the range of 61% to 96%. The performance of the sampling chamber was not affected by air humidity (5%–75% RH), and no breakthrough during sampling was observed. LC-MS/MS determinations allowed for emission testing of diisocyanates and diamines on product surfaces as low as 10–30 ng m(−2) h(−1). SAGE Publications 2023-05-03 2023-06 /pmc/articles/PMC10210200/ /pubmed/37134012 http://dx.doi.org/10.1177/07482337231172811 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Articles
Karlsson, Daniel
Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
title Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
title_full Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
title_fullStr Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
title_full_unstemmed Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
title_short Sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
title_sort sampling chamber with minimal wall surface for simultaneous emission testing of diisocyanates and diamines from polyurethane products
topic Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10210200/
https://www.ncbi.nlm.nih.gov/pubmed/37134012
http://dx.doi.org/10.1177/07482337231172811
work_keys_str_mv AT karlssondaniel samplingchamberwithminimalwallsurfaceforsimultaneousemissiontestingofdiisocyanatesanddiaminesfrompolyurethaneproducts