Cargando…

Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling

OBJECTIVE: To assess the color stability and translucency of full cubic stabilized zirconia (FSZ) following orthodontic bonding with different surface treatments and coffee thermocycling (CTC). METHODS: This in vitro study was conducted on 120 disc-shaped specimens of FSZ. Thirty specimens were sele...

Descripción completa

Detalles Bibliográficos
Autores principales: Hemmati, Yasamin Babaee, Asli, Hamid Neshandar, Nahavandi, Alireza Mahmoudi, Safari, Nika, Falahchai, Mehran
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Association of Orthodontists 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10212774/
https://www.ncbi.nlm.nih.gov/pubmed/36760218
http://dx.doi.org/10.4041/kjod22.144
_version_ 1785047495540211712
author Hemmati, Yasamin Babaee
Asli, Hamid Neshandar
Nahavandi, Alireza Mahmoudi
Safari, Nika
Falahchai, Mehran
author_facet Hemmati, Yasamin Babaee
Asli, Hamid Neshandar
Nahavandi, Alireza Mahmoudi
Safari, Nika
Falahchai, Mehran
author_sort Hemmati, Yasamin Babaee
collection PubMed
description OBJECTIVE: To assess the color stability and translucency of full cubic stabilized zirconia (FSZ) following orthodontic bonding with different surface treatments and coffee thermocycling (CTC). METHODS: This in vitro study was conducted on 120 disc-shaped specimens of FSZ. Thirty specimens were selected as the control group and remained intact. The remaining specimens were randomly divided into three groups based on the type of surface treatment (n = 30) airborne particle abrasion (APA), silica-coating (CoJet), and carbon dioxide (CO(2)) laser. After metal bracket bonding in the test groups, debonding and polishing were performed. Subsequently, all specimens underwent CTC (10,000 cycles). Color parameters, color difference (ΔE(00)), and translucency parameter (TP) were measured three times at baseline (t0), after debonding and polishing (t1), and after CTC (t2). Data were statistically analyzed (α = 0.05). RESULTS: Significant difference existed among the groups regarding ΔE(00)t0t2 (p < 0.001). The APA group showed minimum (ΔE(00) = 1.15 ± 0.53) and the control group showed maximum (ΔE(00) = 0.19 ± 0.02) color stability, with no significant difference between the laser and CoJet groups (p = 0.511). The four groups were significantly different regarding ∆TPt0t2 (p < 0.001). Maximal increases in TP were noted in the CoJet (1.00 ± 0.18) and APA (1.04 ± 0.38) groups while minimal increase was recorded in the control group (0.1 ± 0.02). CONCLUSIONS: Orthodontic treatment makes zirconia restorations susceptible to discoloration and increased translucency. Nonetheless, the recorded ∆E(00) and ∆TP did not exceed the acceptability threshold.
format Online
Article
Text
id pubmed-10212774
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Association of Orthodontists
record_format MEDLINE/PubMed
spelling pubmed-102127742023-05-27 Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling Hemmati, Yasamin Babaee Asli, Hamid Neshandar Nahavandi, Alireza Mahmoudi Safari, Nika Falahchai, Mehran Korean J Orthod Original Article OBJECTIVE: To assess the color stability and translucency of full cubic stabilized zirconia (FSZ) following orthodontic bonding with different surface treatments and coffee thermocycling (CTC). METHODS: This in vitro study was conducted on 120 disc-shaped specimens of FSZ. Thirty specimens were selected as the control group and remained intact. The remaining specimens were randomly divided into three groups based on the type of surface treatment (n = 30) airborne particle abrasion (APA), silica-coating (CoJet), and carbon dioxide (CO(2)) laser. After metal bracket bonding in the test groups, debonding and polishing were performed. Subsequently, all specimens underwent CTC (10,000 cycles). Color parameters, color difference (ΔE(00)), and translucency parameter (TP) were measured three times at baseline (t0), after debonding and polishing (t1), and after CTC (t2). Data were statistically analyzed (α = 0.05). RESULTS: Significant difference existed among the groups regarding ΔE(00)t0t2 (p < 0.001). The APA group showed minimum (ΔE(00) = 1.15 ± 0.53) and the control group showed maximum (ΔE(00) = 0.19 ± 0.02) color stability, with no significant difference between the laser and CoJet groups (p = 0.511). The four groups were significantly different regarding ∆TPt0t2 (p < 0.001). Maximal increases in TP were noted in the CoJet (1.00 ± 0.18) and APA (1.04 ± 0.38) groups while minimal increase was recorded in the control group (0.1 ± 0.02). CONCLUSIONS: Orthodontic treatment makes zirconia restorations susceptible to discoloration and increased translucency. Nonetheless, the recorded ∆E(00) and ∆TP did not exceed the acceptability threshold. Korean Association of Orthodontists 2023-05-25 2023-02-10 /pmc/articles/PMC10212774/ /pubmed/36760218 http://dx.doi.org/10.4041/kjod22.144 Text en © 2023 The Korean Association of Orthodontists. https://creativecommons.org/licenses/by-nc/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0 (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Hemmati, Yasamin Babaee
Asli, Hamid Neshandar
Nahavandi, Alireza Mahmoudi
Safari, Nika
Falahchai, Mehran
Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
title Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
title_full Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
title_fullStr Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
title_full_unstemmed Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
title_short Effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
title_sort effect of orthodontic bonding with different surface treatments on color stability and translucency of full cubic stabilized zirconia after coffee thermocycling
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10212774/
https://www.ncbi.nlm.nih.gov/pubmed/36760218
http://dx.doi.org/10.4041/kjod22.144
work_keys_str_mv AT hemmatiyasaminbabaee effectoforthodonticbondingwithdifferentsurfacetreatmentsoncolorstabilityandtranslucencyoffullcubicstabilizedzirconiaaftercoffeethermocycling
AT aslihamidneshandar effectoforthodonticbondingwithdifferentsurfacetreatmentsoncolorstabilityandtranslucencyoffullcubicstabilizedzirconiaaftercoffeethermocycling
AT nahavandialirezamahmoudi effectoforthodonticbondingwithdifferentsurfacetreatmentsoncolorstabilityandtranslucencyoffullcubicstabilizedzirconiaaftercoffeethermocycling
AT safarinika effectoforthodonticbondingwithdifferentsurfacetreatmentsoncolorstabilityandtranslucencyoffullcubicstabilizedzirconiaaftercoffeethermocycling
AT falahchaimehran effectoforthodonticbondingwithdifferentsurfacetreatmentsoncolorstabilityandtranslucencyoffullcubicstabilizedzirconiaaftercoffeethermocycling