Cargando…

Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports

Despite the high incidence of anterior cruciate ligament injury in patients with tibial plateau fractures, we found no reports about anterior cruciate ligament reconstruction with retained internal fixation hardware for these fractures. Herein, we report 2 male patients with Schatzker type V tibial...

Descripción completa

Detalles Bibliográficos
Autores principales: Ugawa, Satomi, Hiyama, Shuhei, Takahashi, Tsuneari, Yamaguchi, Naoki, Yamanaka, Takuya, Matsumura, Tomohiro, Takeshita, Katsushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10213086/
https://www.ncbi.nlm.nih.gov/pubmed/37251437
http://dx.doi.org/10.1016/j.tcr.2023.100845
_version_ 1785047551923191808
author Ugawa, Satomi
Hiyama, Shuhei
Takahashi, Tsuneari
Yamaguchi, Naoki
Yamanaka, Takuya
Matsumura, Tomohiro
Takeshita, Katsushi
author_facet Ugawa, Satomi
Hiyama, Shuhei
Takahashi, Tsuneari
Yamaguchi, Naoki
Yamanaka, Takuya
Matsumura, Tomohiro
Takeshita, Katsushi
author_sort Ugawa, Satomi
collection PubMed
description Despite the high incidence of anterior cruciate ligament injury in patients with tibial plateau fractures, we found no reports about anterior cruciate ligament reconstruction with retained internal fixation hardware for these fractures. Herein, we report 2 male patients with Schatzker type V tibial plateau fractures and describe the use of retained hardware for internal fixation in tibia. The patients underwent anterior cruciate ligament reconstruction using outside-in technique for the femoral tunnel. Throughout the follow-up, no radiological symptoms of suspected knee osteoarthritis were observed. Accordingly, surgical intervention can be reduced by creating an independent femoral tunnel.
format Online
Article
Text
id pubmed-10213086
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-102130862023-05-27 Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports Ugawa, Satomi Hiyama, Shuhei Takahashi, Tsuneari Yamaguchi, Naoki Yamanaka, Takuya Matsumura, Tomohiro Takeshita, Katsushi Trauma Case Rep Case Report Despite the high incidence of anterior cruciate ligament injury in patients with tibial plateau fractures, we found no reports about anterior cruciate ligament reconstruction with retained internal fixation hardware for these fractures. Herein, we report 2 male patients with Schatzker type V tibial plateau fractures and describe the use of retained hardware for internal fixation in tibia. The patients underwent anterior cruciate ligament reconstruction using outside-in technique for the femoral tunnel. Throughout the follow-up, no radiological symptoms of suspected knee osteoarthritis were observed. Accordingly, surgical intervention can be reduced by creating an independent femoral tunnel. Elsevier 2023-05-16 /pmc/articles/PMC10213086/ /pubmed/37251437 http://dx.doi.org/10.1016/j.tcr.2023.100845 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Ugawa, Satomi
Hiyama, Shuhei
Takahashi, Tsuneari
Yamaguchi, Naoki
Yamanaka, Takuya
Matsumura, Tomohiro
Takeshita, Katsushi
Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports
title Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports
title_full Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports
title_fullStr Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports
title_full_unstemmed Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports
title_short Anterior cruciate ligament reconstruction with retained internal fixation hardware for treating Schatzker type V tibial plateau fracture: Two case reports
title_sort anterior cruciate ligament reconstruction with retained internal fixation hardware for treating schatzker type v tibial plateau fracture: two case reports
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10213086/
https://www.ncbi.nlm.nih.gov/pubmed/37251437
http://dx.doi.org/10.1016/j.tcr.2023.100845
work_keys_str_mv AT ugawasatomi anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports
AT hiyamashuhei anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports
AT takahashitsuneari anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports
AT yamaguchinaoki anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports
AT yamanakatakuya anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports
AT matsumuratomohiro anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports
AT takeshitakatsushi anteriorcruciateligamentreconstructionwithretainedinternalfixationhardwarefortreatingschatzkertypevtibialplateaufracturetwocasereports