Cargando…

Effectiveness of the use of an oscillating positive expiratory pressure device in bronchiectasis with frequent exacerbations: a single-arm pilot study

Impaired airway clearance in patients with non-cystic fibrosis bronchiectasis causes frequent bacterial infection, chronic inflammation, and progressive tissue destruction. We aimed to evaluate whether an oscillating positive expiratory pressure (OPEP) device could allow effective sputum expectorati...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, So Rae, Kim, Sun-Hyung, Kim, Geun-Hyeong, Cho, Jun Yeun, Choi, Hayoung, Lee, Hyun, Ra, Seung Won, Lee, Ki Man, Choe, Kang Hyeon, Oh, Yeon-Mok, Shin, Yoon Mi, Yang, Bumhee
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10213442/
https://www.ncbi.nlm.nih.gov/pubmed/37250647
http://dx.doi.org/10.3389/fmed.2023.1159227
Descripción
Sumario:Impaired airway clearance in patients with non-cystic fibrosis bronchiectasis causes frequent bacterial infection, chronic inflammation, and progressive tissue destruction. We aimed to evaluate whether an oscillating positive expiratory pressure (OPEP) device could allow effective sputum expectoration and prevent acute exacerbations in patients with bronchiectasis who had frequent acute exacerbations. This open-label, single-arm, prospective study included 17 patients who experienced three or more acute exacerbations in the past year. We evaluated the prevention of acute exacerbations, subjective symptom improvement, and change in sputum amount during the use of the Aerobika (Trudell Medical International, London, ON) OPEP device twice daily for 6  months. Of all enrolled patients, only two acute exacerbations occurred during the study period, indicating a significant decrease compared with the number of acute exacerbations before the device use (p < 0.001). Additionally, Bronchiectasis Health Questionnaire score changed from 58.7 to 66.6, showing significant improvement over the treatment period (p < 0.001). The largest sputum volume was observed 3  months after OPEP device use (baseline: 10 ml, 3rd month 25 ml, p = 0.325). There were no major adverse events related to the use of OPEP devices. Twice-daily physiotherapy with OPEP device in patients with bronchiectasis who have frequent exacerbations may facilitate symptomatic improvement and prevention of acute exacerbations without serious adverse events.