Cargando…

Comparative evaluation of the accuracy of 3D-printed denture teeth

OBJECTIVE: This in vitro study compares the accuracy and trueness of various 3D-printed denture teeth. METHODS: A total of 30 specimens were created using various 3D-printed resins, 10 each using Asiga DentaTOOTH resin (Asiga, Australia), Formlabs Denture Teeth Resin (Formlabs GmbH, Germany), and Ne...

Descripción completa

Detalles Bibliográficos
Autores principales: Alalawi, Haidar, Al-Qarni, Faisal D., Gad, Mohammed M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10213981/
https://www.ncbi.nlm.nih.gov/pubmed/37251714
http://dx.doi.org/10.1016/j.sdentj.2023.03.002
_version_ 1785047743886000128
author Alalawi, Haidar
Al-Qarni, Faisal D.
Gad, Mohammed M.
author_facet Alalawi, Haidar
Al-Qarni, Faisal D.
Gad, Mohammed M.
author_sort Alalawi, Haidar
collection PubMed
description OBJECTIVE: This in vitro study compares the accuracy and trueness of various 3D-printed denture teeth. METHODS: A total of 30 specimens were created using various 3D-printed resins, 10 each using Asiga DentaTOOTH resin (Asiga, Australia), Formlabs Denture Teeth Resin (Formlabs GmbH, Germany), and NextDent C&B MFH (Micro Filled Hybrid) resin (Nextdent B.V., Netherlands), respectively. A prefabricated mandibular first molar was scanned using a desktop laser scanner (E3, 3Shape A/S) to create a standard tessellation language file, which served as a “reference tooth” scan. That file was sent to each corresponding printer for printing according to manufacturer recommendations. The printed teeth were scanned with an intraoral scanner (TRIOS 3, 3shape, Copenhagen, Denmark). Trueness and precision were assessed using 3D morphometric analysis software (Geomagic Control X, 3D Systems, Rock Hill, SC, USA). One-way ANOVA was used to analyze the data (α = 0.05). Root mean square error and mean deviations were also calculated. Data analysis was carried out using SPSS (IBM Corp., New York, NY, USA) software. One-way ANOVA with Tukey’s post hoc analysis was used. P-values of<0.05 were regarded as statistically significant. RESULTS: The overall trueness of teeth followed a similar pattern, with the highest trueness recorded with NextDent specimens, while ASIGA specimens had the lowest. When precision was assessed, there were significant differences in occlusal areas between FormLabs and NextDent specimens (p = 0.01) and between FormLabs and ASIGA specimens (p = 0.002). However, ASIGA and NextDent did not differ from one another (p = 0.9). The precision analysis shows that all tested groups had similar values, with no significant differences among them. CONCLUSION: The trueness values of the tested printing systems varied, although the precision values were similar. All evaluated printing systems achieved printing accuracy falling within the clinically acceptable range.
format Online
Article
Text
id pubmed-10213981
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-102139812023-05-27 Comparative evaluation of the accuracy of 3D-printed denture teeth Alalawi, Haidar Al-Qarni, Faisal D. Gad, Mohammed M. Saudi Dent J Original Article OBJECTIVE: This in vitro study compares the accuracy and trueness of various 3D-printed denture teeth. METHODS: A total of 30 specimens were created using various 3D-printed resins, 10 each using Asiga DentaTOOTH resin (Asiga, Australia), Formlabs Denture Teeth Resin (Formlabs GmbH, Germany), and NextDent C&B MFH (Micro Filled Hybrid) resin (Nextdent B.V., Netherlands), respectively. A prefabricated mandibular first molar was scanned using a desktop laser scanner (E3, 3Shape A/S) to create a standard tessellation language file, which served as a “reference tooth” scan. That file was sent to each corresponding printer for printing according to manufacturer recommendations. The printed teeth were scanned with an intraoral scanner (TRIOS 3, 3shape, Copenhagen, Denmark). Trueness and precision were assessed using 3D morphometric analysis software (Geomagic Control X, 3D Systems, Rock Hill, SC, USA). One-way ANOVA was used to analyze the data (α = 0.05). Root mean square error and mean deviations were also calculated. Data analysis was carried out using SPSS (IBM Corp., New York, NY, USA) software. One-way ANOVA with Tukey’s post hoc analysis was used. P-values of<0.05 were regarded as statistically significant. RESULTS: The overall trueness of teeth followed a similar pattern, with the highest trueness recorded with NextDent specimens, while ASIGA specimens had the lowest. When precision was assessed, there were significant differences in occlusal areas between FormLabs and NextDent specimens (p = 0.01) and between FormLabs and ASIGA specimens (p = 0.002). However, ASIGA and NextDent did not differ from one another (p = 0.9). The precision analysis shows that all tested groups had similar values, with no significant differences among them. CONCLUSION: The trueness values of the tested printing systems varied, although the precision values were similar. All evaluated printing systems achieved printing accuracy falling within the clinically acceptable range. Elsevier 2023-05 2023-03-15 /pmc/articles/PMC10213981/ /pubmed/37251714 http://dx.doi.org/10.1016/j.sdentj.2023.03.002 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Alalawi, Haidar
Al-Qarni, Faisal D.
Gad, Mohammed M.
Comparative evaluation of the accuracy of 3D-printed denture teeth
title Comparative evaluation of the accuracy of 3D-printed denture teeth
title_full Comparative evaluation of the accuracy of 3D-printed denture teeth
title_fullStr Comparative evaluation of the accuracy of 3D-printed denture teeth
title_full_unstemmed Comparative evaluation of the accuracy of 3D-printed denture teeth
title_short Comparative evaluation of the accuracy of 3D-printed denture teeth
title_sort comparative evaluation of the accuracy of 3d-printed denture teeth
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10213981/
https://www.ncbi.nlm.nih.gov/pubmed/37251714
http://dx.doi.org/10.1016/j.sdentj.2023.03.002
work_keys_str_mv AT alalawihaidar comparativeevaluationoftheaccuracyof3dprinteddentureteeth
AT alqarnifaisald comparativeevaluationoftheaccuracyof3dprinteddentureteeth
AT gadmohammedm comparativeevaluationoftheaccuracyof3dprinteddentureteeth