Cargando…

Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model

Background: Endoscopic retrograde cholangiopancreatography (ERCP) is crucial to the treatment of biliopancreatic diseases with iatrogenic perforation as a potential complication. As of yet, the wall load during ERCP is unknown, as it is not directly measurable during an ERCP in patients. Methods: In...

Descripción completa

Detalles Bibliográficos
Autores principales: Schneider, Julian, Duckworth-Mothes, Benedikt, Schweizer, Ulrich, Königsrainer, Alfred, Fisch, Jakob, Wichmann, Dörte
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10215224/
https://www.ncbi.nlm.nih.gov/pubmed/37237593
http://dx.doi.org/10.3390/bioengineering10050523
_version_ 1785048013011419136
author Schneider, Julian
Duckworth-Mothes, Benedikt
Schweizer, Ulrich
Königsrainer, Alfred
Fisch, Jakob
Wichmann, Dörte
author_facet Schneider, Julian
Duckworth-Mothes, Benedikt
Schweizer, Ulrich
Königsrainer, Alfred
Fisch, Jakob
Wichmann, Dörte
author_sort Schneider, Julian
collection PubMed
description Background: Endoscopic retrograde cholangiopancreatography (ERCP) is crucial to the treatment of biliopancreatic diseases with iatrogenic perforation as a potential complication. As of yet, the wall load during ERCP is unknown, as it is not directly measurable during an ERCP in patients. Methods: In a life-like, animal-free model, a sensor system consisting of five load cells was attached to the artificial intestines (sensors 1 + 2: pyloric canal–pyloric antrum, sensor 3: duodenal bulb, sensor 4: descending part of the duodenum, sensor 5: distal to the papilla). Measurements were made with five duodenoscopes (n = 4 reusable and n = 1 single use). Results: Fifteen standardized duodenoscopies were performed. Peak stresses were found at the antrum during the gastrointestinal transit (sensor 1 max. 8.95 N, sensor 2 max. 2.79 N). The load reduced from the proximal to the distal duodenum and the greatest load in the duodenum was discovered at the level of the papilla in 80.0% (sensor 3 max. 2.06 N). Conclusions: For the first time, intraprocedural load measurements and exerting forces obtained during a duodenoscopy for ERCP in an artificial model were recorded. None of the tested duodenoscopes were classified as dangerous for patient safety.
format Online
Article
Text
id pubmed-10215224
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102152242023-05-27 Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model Schneider, Julian Duckworth-Mothes, Benedikt Schweizer, Ulrich Königsrainer, Alfred Fisch, Jakob Wichmann, Dörte Bioengineering (Basel) Article Background: Endoscopic retrograde cholangiopancreatography (ERCP) is crucial to the treatment of biliopancreatic diseases with iatrogenic perforation as a potential complication. As of yet, the wall load during ERCP is unknown, as it is not directly measurable during an ERCP in patients. Methods: In a life-like, animal-free model, a sensor system consisting of five load cells was attached to the artificial intestines (sensors 1 + 2: pyloric canal–pyloric antrum, sensor 3: duodenal bulb, sensor 4: descending part of the duodenum, sensor 5: distal to the papilla). Measurements were made with five duodenoscopes (n = 4 reusable and n = 1 single use). Results: Fifteen standardized duodenoscopies were performed. Peak stresses were found at the antrum during the gastrointestinal transit (sensor 1 max. 8.95 N, sensor 2 max. 2.79 N). The load reduced from the proximal to the distal duodenum and the greatest load in the duodenum was discovered at the level of the papilla in 80.0% (sensor 3 max. 2.06 N). Conclusions: For the first time, intraprocedural load measurements and exerting forces obtained during a duodenoscopy for ERCP in an artificial model were recorded. None of the tested duodenoscopes were classified as dangerous for patient safety. MDPI 2023-04-26 /pmc/articles/PMC10215224/ /pubmed/37237593 http://dx.doi.org/10.3390/bioengineering10050523 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Schneider, Julian
Duckworth-Mothes, Benedikt
Schweizer, Ulrich
Königsrainer, Alfred
Fisch, Jakob
Wichmann, Dörte
Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model
title Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model
title_full Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model
title_fullStr Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model
title_full_unstemmed Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model
title_short Exerting Forces and Wall Load during Duodenoscopy for ERCP: An Experimental Measurement in an Artificial Model
title_sort exerting forces and wall load during duodenoscopy for ercp: an experimental measurement in an artificial model
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10215224/
https://www.ncbi.nlm.nih.gov/pubmed/37237593
http://dx.doi.org/10.3390/bioengineering10050523
work_keys_str_mv AT schneiderjulian exertingforcesandwallloadduringduodenoscopyforercpanexperimentalmeasurementinanartificialmodel
AT duckworthmothesbenedikt exertingforcesandwallloadduringduodenoscopyforercpanexperimentalmeasurementinanartificialmodel
AT schweizerulrich exertingforcesandwallloadduringduodenoscopyforercpanexperimentalmeasurementinanartificialmodel
AT konigsraineralfred exertingforcesandwallloadduringduodenoscopyforercpanexperimentalmeasurementinanartificialmodel
AT fischjakob exertingforcesandwallloadduringduodenoscopyforercpanexperimentalmeasurementinanartificialmodel
AT wichmanndorte exertingforcesandwallloadduringduodenoscopyforercpanexperimentalmeasurementinanartificialmodel