Cargando…

Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography

Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Xu, Li, Beibei, Tong, Xiaoyu, Fan, Yong, Wang, Shigeng, Liu, Yijun, Fang, Xin, Liu, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10217305/
https://www.ncbi.nlm.nih.gov/pubmed/37238235
http://dx.doi.org/10.3390/diagnostics13101751
_version_ 1785048504694996992
author Wang, Xu
Li, Beibei
Tong, Xiaoyu
Fan, Yong
Wang, Shigeng
Liu, Yijun
Fang, Xin
Liu, Lei
author_facet Wang, Xu
Li, Beibei
Tong, Xiaoyu
Fan, Yong
Wang, Shigeng
Liu, Yijun
Fang, Xin
Liu, Lei
author_sort Wang, Xu
collection PubMed
description Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (D(HAP (water)), D(HAP (fat)), D(HAP (blood)), D(Ca (water)), and D(Ca (fat))) in the trabecular bone of vertebral bodies (T11–L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman’s correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between D(HAP (water)), D(HAP (fat)), D(HAP (blood)), D(Ca (water)), and D(Ca (fat)) and the QCT-derived BMD. D(HAP (water)) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with D(HAP (water)) ≤ 107.4 mg/cm(3), respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with D(HAP (water)) ≤ 89.62 mg/cm(3), respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with D(HAP (water)) having the highest diagnostic accuracy.
format Online
Article
Text
id pubmed-10217305
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102173052023-05-27 Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography Wang, Xu Li, Beibei Tong, Xiaoyu Fan, Yong Wang, Shigeng Liu, Yijun Fang, Xin Liu, Lei Diagnostics (Basel) Article Purpose: The purpose of this study was to evaluate the diagnostic accuracy when using various base material pairs (BMPs) in dual-energy computed tomography (DECT), and to establish corresponding diagnostic standards for assessing bone status through comparison with quantitative computed tomography (QCT). Methods: This prospective study enrolled a total of 469 patients who underwent both non-enhanced chest CT scans under conventional kVp and abdominal DECT. The bone densities of hydroxyapatite (water), hydroxyapatite (fat), hydroxyapatite (blood), calcium (water), and calcium (fat) (D(HAP (water)), D(HAP (fat)), D(HAP (blood)), D(Ca (water)), and D(Ca (fat))) in the trabecular bone of vertebral bodies (T11–L1) were measured, along with bone mineral density (BMD) via QCT. Intraclass correlation coefficient (ICC) analysis was used to assess the agreement of the measurements. Spearman’s correlation test was performed to analyze the relationship between the DECT- and QCT-derived BMD. Receiver operator characteristic (ROC) curves were generated to determine the optimal diagnostic thresholds of various BMPs for diagnosing osteopenia and osteoporosis. Results: A total of 1371 vertebral bodies were measured, and QCT identified 393 with osteoporosis and 442 with osteopenia. Strong correlations were observed between D(HAP (water)), D(HAP (fat)), D(HAP (blood)), D(Ca (water)), and D(Ca (fat)) and the QCT-derived BMD. D(HAP (water)) showed the best predictive capability for osteopenia and osteoporosis. The area under the ROC curve, sensitivity, and specificity for identifying osteopenia were 0.956, 86.88%, and 88.91% with D(HAP (water)) ≤ 107.4 mg/cm(3), respectively. The corresponding values for identifying osteoporosis were 0.999, 99.24%, and 99.53% with D(HAP (water)) ≤ 89.62 mg/cm(3), respectively. Conclusions: Bone density measurement using various BMPs in DECT enables the quantification of vertebral BMD and the diagnosis of osteoporosis, with D(HAP (water)) having the highest diagnostic accuracy. MDPI 2023-05-16 /pmc/articles/PMC10217305/ /pubmed/37238235 http://dx.doi.org/10.3390/diagnostics13101751 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Xu
Li, Beibei
Tong, Xiaoyu
Fan, Yong
Wang, Shigeng
Liu, Yijun
Fang, Xin
Liu, Lei
Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
title Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
title_full Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
title_fullStr Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
title_full_unstemmed Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
title_short Diagnostic Accuracy of Dual-Energy CT Material Decomposition Technique for Assessing Bone Status Compared with Quantitative Computed Tomography
title_sort diagnostic accuracy of dual-energy ct material decomposition technique for assessing bone status compared with quantitative computed tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10217305/
https://www.ncbi.nlm.nih.gov/pubmed/37238235
http://dx.doi.org/10.3390/diagnostics13101751
work_keys_str_mv AT wangxu diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT libeibei diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT tongxiaoyu diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT fanyong diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT wangshigeng diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT liuyijun diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT fangxin diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography
AT liulei diagnosticaccuracyofdualenergyctmaterialdecompositiontechniqueforassessingbonestatuscomparedwithquantitativecomputedtomography