Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation
Astigmatism is a visually significant condition that can develop after keratoplasty. The management of post-keratoplasty astigmatism can be performed both when transplant sutures are in place and when they have been removed. Fundamental for astigmatism management is its identification and characteri...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10218853/ https://www.ncbi.nlm.nih.gov/pubmed/37240568 http://dx.doi.org/10.3390/jcm12103462 |
_version_ | 1785048872368734208 |
---|---|
author | Borgia, Alfredo Romano, Vito Romano, Davide Pagano, Luca Vagge, Aldo Giannaccare, Giuseppe Ahmed, Mahmoud Gadhvi, Kunal Menassa, Nardine Ahmad, Mohammad Kaye, Stephen Coco, Giulia |
author_facet | Borgia, Alfredo Romano, Vito Romano, Davide Pagano, Luca Vagge, Aldo Giannaccare, Giuseppe Ahmed, Mahmoud Gadhvi, Kunal Menassa, Nardine Ahmad, Mohammad Kaye, Stephen Coco, Giulia |
author_sort | Borgia, Alfredo |
collection | PubMed |
description | Astigmatism is a visually significant condition that can develop after keratoplasty. The management of post-keratoplasty astigmatism can be performed both when transplant sutures are in place and when they have been removed. Fundamental for astigmatism management is its identification and characterization in terms of type, amount, and direction. Commonly, post-keratoplasty astigmatism is evaluated through corneal tomography or topo-aberrometry; however, many other techniques can be used in case these instruments are not readily available. Here, we describe several low-tech and high-tech techniques used for post-keratoplasty astigmatism detection in order to quickly understand if it contributes to low vision quality and to determine its characteristics. The management of post-keratoplasty astigmatism through suture manipulation is also described. |
format | Online Article Text |
id | pubmed-10218853 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102188532023-05-27 Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation Borgia, Alfredo Romano, Vito Romano, Davide Pagano, Luca Vagge, Aldo Giannaccare, Giuseppe Ahmed, Mahmoud Gadhvi, Kunal Menassa, Nardine Ahmad, Mohammad Kaye, Stephen Coco, Giulia J Clin Med Review Astigmatism is a visually significant condition that can develop after keratoplasty. The management of post-keratoplasty astigmatism can be performed both when transplant sutures are in place and when they have been removed. Fundamental for astigmatism management is its identification and characterization in terms of type, amount, and direction. Commonly, post-keratoplasty astigmatism is evaluated through corneal tomography or topo-aberrometry; however, many other techniques can be used in case these instruments are not readily available. Here, we describe several low-tech and high-tech techniques used for post-keratoplasty astigmatism detection in order to quickly understand if it contributes to low vision quality and to determine its characteristics. The management of post-keratoplasty astigmatism through suture manipulation is also described. MDPI 2023-05-14 /pmc/articles/PMC10218853/ /pubmed/37240568 http://dx.doi.org/10.3390/jcm12103462 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Borgia, Alfredo Romano, Vito Romano, Davide Pagano, Luca Vagge, Aldo Giannaccare, Giuseppe Ahmed, Mahmoud Gadhvi, Kunal Menassa, Nardine Ahmad, Mohammad Kaye, Stephen Coco, Giulia Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation |
title | Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation |
title_full | Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation |
title_fullStr | Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation |
title_full_unstemmed | Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation |
title_short | Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation |
title_sort | managing post-keratoplasty astigmatism: high-tech vs. low-tech imaging techniques for guiding suture manipulation |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10218853/ https://www.ncbi.nlm.nih.gov/pubmed/37240568 http://dx.doi.org/10.3390/jcm12103462 |
work_keys_str_mv | AT borgiaalfredo managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT romanovito managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT romanodavide managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT paganoluca managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT vaggealdo managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT giannaccaregiuseppe managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT ahmedmahmoud managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT gadhvikunal managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT menassanardine managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT ahmadmohammad managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT kayestephen managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation AT cocogiulia managingpostkeratoplastyastigmatismhightechvslowtechimagingtechniquesforguidingsuturemanipulation |