Cargando…
Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models
The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cat...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10219279/ https://www.ncbi.nlm.nih.gov/pubmed/37240694 http://dx.doi.org/10.3390/jcm12103588 |
_version_ | 1785048972235112448 |
---|---|
author | Mencucci, Rita Morelli, Alberto Cennamo, Michela Roszkowska, Anna Maria Favuzza, Eleonora |
author_facet | Mencucci, Rita Morelli, Alberto Cennamo, Michela Roszkowska, Anna Maria Favuzza, Eleonora |
author_sort | Mencucci, Rita |
collection | PubMed |
description | The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cataract surgery with bilateral implantation of Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc., Jacksonville, FL, USA), Vivinex Impress XY1-EM (Hoya Surgical Optics, Singapore) or IsoPure 123 (PhysIOL, Liege, Belgium) IOLs. Three months postoperatively, monocular and binocular uncorrected and corrected distant, and intermediate and near visual acuities were measured. Binocular defocus curve, photopic contrast sensitivity, Point Spread Function (PSF), low order aberrations (LOAs), high order aberrations (HOAs), objective scatter index (OSI), halo and glare perception were also evaluated. This study included a total of 72 eyes from 36 patients. Visual acuity outcomes, PSF, LOAs, HOAs and OSI were similar between groups. There were no statistically significant differences in terms of photopic contrast sensitivity, halo or glare perception. In patients without ocular comorbidities, the Eyhance ICB00 IOL, the Vivinex Impress IOL and the Isopure IOL—even though based on different optical properties—provided similar results in terms of visual acuity, contrast sensitivity and intraocular aberrations, with no influence on photic phenomena. |
format | Online Article Text |
id | pubmed-10219279 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102192792023-05-27 Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models Mencucci, Rita Morelli, Alberto Cennamo, Michela Roszkowska, Anna Maria Favuzza, Eleonora J Clin Med Article The purpose of this study was to compare the visual performance and optical quality between three new enhanced monofocal intraocular lenses (IOLs). This retrospective study included patients affected by cataracts with corneal astigmatism less than 0.75 D and no ocular comorbidities who underwent cataract surgery with bilateral implantation of Tecnis Eyhance ICB00 (Johnson & Johnson Vision Care, Inc., Jacksonville, FL, USA), Vivinex Impress XY1-EM (Hoya Surgical Optics, Singapore) or IsoPure 123 (PhysIOL, Liege, Belgium) IOLs. Three months postoperatively, monocular and binocular uncorrected and corrected distant, and intermediate and near visual acuities were measured. Binocular defocus curve, photopic contrast sensitivity, Point Spread Function (PSF), low order aberrations (LOAs), high order aberrations (HOAs), objective scatter index (OSI), halo and glare perception were also evaluated. This study included a total of 72 eyes from 36 patients. Visual acuity outcomes, PSF, LOAs, HOAs and OSI were similar between groups. There were no statistically significant differences in terms of photopic contrast sensitivity, halo or glare perception. In patients without ocular comorbidities, the Eyhance ICB00 IOL, the Vivinex Impress IOL and the Isopure IOL—even though based on different optical properties—provided similar results in terms of visual acuity, contrast sensitivity and intraocular aberrations, with no influence on photic phenomena. MDPI 2023-05-21 /pmc/articles/PMC10219279/ /pubmed/37240694 http://dx.doi.org/10.3390/jcm12103588 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mencucci, Rita Morelli, Alberto Cennamo, Michela Roszkowska, Anna Maria Favuzza, Eleonora Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models |
title | Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models |
title_full | Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models |
title_fullStr | Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models |
title_full_unstemmed | Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models |
title_short | Enhanced Monofocal Intraocular Lenses: A Retrospective, Comparative Study between Three Different Models |
title_sort | enhanced monofocal intraocular lenses: a retrospective, comparative study between three different models |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10219279/ https://www.ncbi.nlm.nih.gov/pubmed/37240694 http://dx.doi.org/10.3390/jcm12103588 |
work_keys_str_mv | AT mencuccirita enhancedmonofocalintraocularlensesaretrospectivecomparativestudybetweenthreedifferentmodels AT morellialberto enhancedmonofocalintraocularlensesaretrospectivecomparativestudybetweenthreedifferentmodels AT cennamomichela enhancedmonofocalintraocularlensesaretrospectivecomparativestudybetweenthreedifferentmodels AT roszkowskaannamaria enhancedmonofocalintraocularlensesaretrospectivecomparativestudybetweenthreedifferentmodels AT favuzzaeleonora enhancedmonofocalintraocularlensesaretrospectivecomparativestudybetweenthreedifferentmodels |