Cargando…

Improving animal-specific radiotherapy quality assurance for kilovoltage X-ray radiotherapy using a 3D printed dog skull water phantom

BACKGROUND: Accurate dose assessment during animal radiotherapy is beneficial for veterinary medicine and medical education. AIM: To visualize the radiation treatment distribution of orthovoltage X-ray equipment in clinical practice using Monte Carlo simulations and create a dog skull water phantom...

Descripción completa

Detalles Bibliográficos
Autores principales: Tanabe, Yoshinori, Iseri, Toshie, Onizuka, Ryouta, Ishida, Takayuki, Eto, Hidetoshi, Nakaichi, Munekazu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Faculty of Veterinary Medicine 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10219815/
https://www.ncbi.nlm.nih.gov/pubmed/37251269
http://dx.doi.org/10.5455/OVJ.2023.v13.i4.4
Descripción
Sumario:BACKGROUND: Accurate dose assessment during animal radiotherapy is beneficial for veterinary medicine and medical education. AIM: To visualize the radiation treatment distribution of orthovoltage X-ray equipment in clinical practice using Monte Carlo simulations and create a dog skull water phantom for animal-specific radiotherapy. METHODS: EGSnrc-based BEAMnrc and DOSXYZnrc codes were used to simulate orthovoltage dose distributions. At 10, 20, 30, 40, 50, and 80 mm in a water phantom, the depth dose was measured with waterproof Farmer dosimetry chambers, and the diagonal off-axis ratio was measured with Gafchromic EBT3 film to simulate orthovoltage dose distributions. Energy differences between orthovoltage and linear accelerated radiotherapy were assessed with a heterogeneous bone and tissue virtual phantom. The animal-specific phantom for radiotherapy quality assurance (QA) was created from CT scans of a dog and printed with a three-dimensional printer using polyamide 12 nylon, with insertion points for dosimetry chambers and Gafchromic EBT3 film. RESULTS: Monte Carlo simulated and measured dose distributions differed by no more than 2.0% along the central axis up to a depth of 80 mm. The anode heel effect occurred in shallow areas. The orthovoltage radiotherapy percentage depth dose in bone was >40%. Build-up was >40%, with build-down after bone exit, whereas linear accelerator radiotherapy absorption changed little in the bone. A highly water-impermeable, animal-specific dog skull water phantom could be created to evaluate dose distribution. CONCLUSION: Animal-specific water phantoms and Monte Carlo simulated pre-treatment radiotherapy are useful QA for orthovoltage radiotherapy and yield a visually familiar phantom that will be useful for veterinary medical education.