Cargando…
Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review
Acquired von Willebrand factor deficiency has been described in patients with aortic valve stenosis due to high shear forces developed during passage through the narrowed valve orifice, which determines structural changes in this molecule. Similar flow conditions are present in patients with an aort...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220691/ https://www.ncbi.nlm.nih.gov/pubmed/37241186 http://dx.doi.org/10.3390/medicina59050954 |
_version_ | 1785049278263066624 |
---|---|
author | Grigorescu, Andrei Emanuel Anghel, Andrei Buriman, Darius Gheorghe Feier, Horea |
author_facet | Grigorescu, Andrei Emanuel Anghel, Andrei Buriman, Darius Gheorghe Feier, Horea |
author_sort | Grigorescu, Andrei Emanuel |
collection | PubMed |
description | Acquired von Willebrand factor deficiency has been described in patients with aortic valve stenosis due to high shear forces developed during passage through the narrowed valve orifice, which determines structural changes in this molecule. Similar flow conditions are present in patients with an aortic prosthesis that presents a patient-prosthesis mismatch. Patient-prosthesis mismatch is described by the smaller effective orifice area of the prosthesis than the native valve, which would probably determine similar changes in the molecules of the von Willebrand factor, leading to acquiring von Willebrand deficiency. |
format | Online Article Text |
id | pubmed-10220691 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102206912023-05-28 Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review Grigorescu, Andrei Emanuel Anghel, Andrei Buriman, Darius Gheorghe Feier, Horea Medicina (Kaunas) Review Acquired von Willebrand factor deficiency has been described in patients with aortic valve stenosis due to high shear forces developed during passage through the narrowed valve orifice, which determines structural changes in this molecule. Similar flow conditions are present in patients with an aortic prosthesis that presents a patient-prosthesis mismatch. Patient-prosthesis mismatch is described by the smaller effective orifice area of the prosthesis than the native valve, which would probably determine similar changes in the molecules of the von Willebrand factor, leading to acquiring von Willebrand deficiency. MDPI 2023-05-16 /pmc/articles/PMC10220691/ /pubmed/37241186 http://dx.doi.org/10.3390/medicina59050954 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Review Grigorescu, Andrei Emanuel Anghel, Andrei Buriman, Darius Gheorghe Feier, Horea Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review |
title | Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review |
title_full | Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review |
title_fullStr | Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review |
title_full_unstemmed | Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review |
title_short | Acquired Von Willebrand Factor Deficiency at Patient-Prosthesis Mismatch after AVR Procedure—A Narrative Review |
title_sort | acquired von willebrand factor deficiency at patient-prosthesis mismatch after avr procedure—a narrative review |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220691/ https://www.ncbi.nlm.nih.gov/pubmed/37241186 http://dx.doi.org/10.3390/medicina59050954 |
work_keys_str_mv | AT grigorescuandreiemanuel acquiredvonwillebrandfactordeficiencyatpatientprosthesismismatchafteravrprocedureanarrativereview AT anghelandrei acquiredvonwillebrandfactordeficiencyatpatientprosthesismismatchafteravrprocedureanarrativereview AT burimandariusgheorghe acquiredvonwillebrandfactordeficiencyatpatientprosthesismismatchafteravrprocedureanarrativereview AT feierhorea acquiredvonwillebrandfactordeficiencyatpatientprosthesismismatchafteravrprocedureanarrativereview |