Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines

The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distort...

Descripción completa

Detalles Bibliográficos
Autores principales: Piechota, Piotr, Synowiec, Piotr, Andruszkiewicz, Artur, Wędrychowicz, Wiesław, Wróblewska, Elżbieta, Mrowiec, Andrzej
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220936/
https://www.ncbi.nlm.nih.gov/pubmed/37430591
http://dx.doi.org/10.3390/s23104677
_version_ 1785049336668749824
author Piechota, Piotr
Synowiec, Piotr
Andruszkiewicz, Artur
Wędrychowicz, Wiesław
Wróblewska, Elżbieta
Mrowiec, Andrzej
author_facet Piechota, Piotr
Synowiec, Piotr
Andruszkiewicz, Artur
Wędrychowicz, Wiesław
Wróblewska, Elżbieta
Mrowiec, Andrzej
author_sort Piechota, Piotr
collection PubMed
description The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3–15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve’s closure: 1/3 and 1/2 of the valve’s height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations.
format Online
Article
Text
id pubmed-10220936
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102209362023-05-28 Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines Piechota, Piotr Synowiec, Piotr Andruszkiewicz, Artur Wędrychowicz, Wiesław Wróblewska, Elżbieta Mrowiec, Andrzej Sensors (Basel) Article The aim of this work is to experimentally determine and evaluate the value of the correction factor for ultrasonic flow meters in order to improve their accuracy. This article concerns flow velocity measurement with the use of an ultrasonic flow meter in the area of disturbed flow behind the distorting element. Clamp-on ultrasonic flow meters are popular among measurement technologies due to their high accuracy and easy, non-invasive installation, because the sensors are mounted directly on the outer surface of the pipe. In industrial applications, installation space is usually limited and, therefore, flow meters frequently have to be mounted directly behind flow disturbances. In such cases, it is necessary to determine the value of the correction factor. The disturbing element was a knife gate valve, a valve often used in flow installations. Water flow velocity tests were performed using an ultrasonic flow meter with clamp-on sensors on the pipeline. The research was performed in 2 series of measurements with different Reynolds numbers of 35,000 and 70,000, which correspond to a velocity of approximately 0.9 m/s and 1.8 m/s. The tests were carried out at different distances from the source of interference, within the range of 3–15 DN (pipe nominal diameter). The position of the sensors at successive measurement points on the circuit of the pipeline was changed by 30 degrees. Flow velocity measurements were carried out for two different levels of the valve’s closure: 1/3 and 1/2 of the valve’s height. For the collected velocity values at single measurement points, the values of the correction coefficient, K, were determined. The results of the tests and calculations prove that compensation error of measurement performed behind the disturbance without keeping the required straight sections of the pipeline is possible by using the factor K*. The analysis of the results made it possible to identify the optimal measuring point at a distance from the knife gate valve as being smaller than specified in the standards and recommendations. MDPI 2023-05-11 /pmc/articles/PMC10220936/ /pubmed/37430591 http://dx.doi.org/10.3390/s23104677 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Piechota, Piotr
Synowiec, Piotr
Andruszkiewicz, Artur
Wędrychowicz, Wiesław
Wróblewska, Elżbieta
Mrowiec, Andrzej
Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
title Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
title_full Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
title_fullStr Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
title_full_unstemmed Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
title_short Experimental Determination Influence of Flow Disturbances behind the Knife Gate Valve on the Indications of the Ultrasonic Flow Meter with Clamp-On Sensors on Pipelines
title_sort experimental determination influence of flow disturbances behind the knife gate valve on the indications of the ultrasonic flow meter with clamp-on sensors on pipelines
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220936/
https://www.ncbi.nlm.nih.gov/pubmed/37430591
http://dx.doi.org/10.3390/s23104677
work_keys_str_mv AT piechotapiotr experimentaldeterminationinfluenceofflowdisturbancesbehindtheknifegatevalveontheindicationsoftheultrasonicflowmeterwithclamponsensorsonpipelines
AT synowiecpiotr experimentaldeterminationinfluenceofflowdisturbancesbehindtheknifegatevalveontheindicationsoftheultrasonicflowmeterwithclamponsensorsonpipelines
AT andruszkiewiczartur experimentaldeterminationinfluenceofflowdisturbancesbehindtheknifegatevalveontheindicationsoftheultrasonicflowmeterwithclamponsensorsonpipelines
AT wedrychowiczwiesław experimentaldeterminationinfluenceofflowdisturbancesbehindtheknifegatevalveontheindicationsoftheultrasonicflowmeterwithclamponsensorsonpipelines
AT wroblewskaelzbieta experimentaldeterminationinfluenceofflowdisturbancesbehindtheknifegatevalveontheindicationsoftheultrasonicflowmeterwithclamponsensorsonpipelines
AT mrowiecandrzej experimentaldeterminationinfluenceofflowdisturbancesbehindtheknifegatevalveontheindicationsoftheultrasonicflowmeterwithclamponsensorsonpipelines