Cargando…
Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls
The intrinsic and liveness detection behavior of electrocardiogram (ECG) signals has made it an emerging biometric modality for the researcher with several applications including forensic, surveillance and security. The main challenge is the low recognition performance with datasets of large populat...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220968/ https://www.ncbi.nlm.nih.gov/pubmed/37430549 http://dx.doi.org/10.3390/s23104635 |
_version_ | 1785049344405143552 |
---|---|
author | Asif, Muhammad Sheharyar Faisal, Muhammad Shahzad Dar, Muhammad Najam Hamdi, Monia Elmannai, Hela Rizwan, Atif Abbas, Muhammad |
author_facet | Asif, Muhammad Sheharyar Faisal, Muhammad Shahzad Dar, Muhammad Najam Hamdi, Monia Elmannai, Hela Rizwan, Atif Abbas, Muhammad |
author_sort | Asif, Muhammad Sheharyar |
collection | PubMed |
description | The intrinsic and liveness detection behavior of electrocardiogram (ECG) signals has made it an emerging biometric modality for the researcher with several applications including forensic, surveillance and security. The main challenge is the low recognition performance with datasets of large populations, including healthy and heart-disease patients, with a short interval of an ECG signal. This research proposes a novel method with the feature-level fusion of the discrete wavelet transform and a one-dimensional convolutional recurrent neural network (1D-CRNN). ECG signals were preprocessed by removing high-frequency powerline interference, followed by a low-pass filter with a cutoff frequency of 1.5 Hz for physiological noises and by baseline drift removal. The preprocessed signal is segmented with PQRST peaks, while the segmented signals are passed through Coiflets’ 5 Discrete Wavelet Transform for conventional feature extraction. The 1D-CRNN with two long short-term memory (LSTM) layers followed by three 1D convolutional layers was applied for deep learning-based feature extraction. These combinations of features result in biometric recognition accuracies of 80.64%, 98.81% and 99.62% for the ECG-ID, MIT-BIH and NSR-DB datasets, respectively. At the same time, 98.24% is achieved when combining all of these datasets. This research also compares conventional feature extraction, deep learning-based feature extraction and a combination of these for performance enhancement, compared to transfer learning approaches such as VGG-19, ResNet-152 and Inception-v3 with a small segment of ECG data. |
format | Online Article Text |
id | pubmed-10220968 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102209682023-05-28 Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls Asif, Muhammad Sheharyar Faisal, Muhammad Shahzad Dar, Muhammad Najam Hamdi, Monia Elmannai, Hela Rizwan, Atif Abbas, Muhammad Sensors (Basel) Article The intrinsic and liveness detection behavior of electrocardiogram (ECG) signals has made it an emerging biometric modality for the researcher with several applications including forensic, surveillance and security. The main challenge is the low recognition performance with datasets of large populations, including healthy and heart-disease patients, with a short interval of an ECG signal. This research proposes a novel method with the feature-level fusion of the discrete wavelet transform and a one-dimensional convolutional recurrent neural network (1D-CRNN). ECG signals were preprocessed by removing high-frequency powerline interference, followed by a low-pass filter with a cutoff frequency of 1.5 Hz for physiological noises and by baseline drift removal. The preprocessed signal is segmented with PQRST peaks, while the segmented signals are passed through Coiflets’ 5 Discrete Wavelet Transform for conventional feature extraction. The 1D-CRNN with two long short-term memory (LSTM) layers followed by three 1D convolutional layers was applied for deep learning-based feature extraction. These combinations of features result in biometric recognition accuracies of 80.64%, 98.81% and 99.62% for the ECG-ID, MIT-BIH and NSR-DB datasets, respectively. At the same time, 98.24% is achieved when combining all of these datasets. This research also compares conventional feature extraction, deep learning-based feature extraction and a combination of these for performance enhancement, compared to transfer learning approaches such as VGG-19, ResNet-152 and Inception-v3 with a small segment of ECG data. MDPI 2023-05-10 /pmc/articles/PMC10220968/ /pubmed/37430549 http://dx.doi.org/10.3390/s23104635 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Asif, Muhammad Sheharyar Faisal, Muhammad Shahzad Dar, Muhammad Najam Hamdi, Monia Elmannai, Hela Rizwan, Atif Abbas, Muhammad Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls |
title | Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls |
title_full | Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls |
title_fullStr | Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls |
title_full_unstemmed | Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls |
title_short | Hybrid Deep Learning and Discrete Wavelet Transform-Based ECG Biometric Recognition for Arrhythmic Patients and Healthy Controls |
title_sort | hybrid deep learning and discrete wavelet transform-based ecg biometric recognition for arrhythmic patients and healthy controls |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10220968/ https://www.ncbi.nlm.nih.gov/pubmed/37430549 http://dx.doi.org/10.3390/s23104635 |
work_keys_str_mv | AT asifmuhammadsheharyar hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols AT faisalmuhammadshahzad hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols AT darmuhammadnajam hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols AT hamdimonia hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols AT elmannaihela hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols AT rizwanatif hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols AT abbasmuhammad hybriddeeplearninganddiscretewavelettransformbasedecgbiometricrecognitionforarrhythmicpatientsandhealthycontrols |