Cargando…

Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table

The total harmonic distortion (THD) index and its calculation methods are presented to calibrate the sinusoidal motion of the low-frequency angular acceleration rotary table (LFAART) and make up the incomprehensive evaluation based on the angular acceleration amplitude and frequency error indexes. T...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Renjian, Yan, Jiaxuan, Wu, Yinfeng, Yu, Ning, Yin, Xudong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221667/
https://www.ncbi.nlm.nih.gov/pubmed/37430788
http://dx.doi.org/10.3390/s23104876
_version_ 1785049511027015680
author Feng, Renjian
Yan, Jiaxuan
Wu, Yinfeng
Yu, Ning
Yin, Xudong
author_facet Feng, Renjian
Yan, Jiaxuan
Wu, Yinfeng
Yu, Ning
Yin, Xudong
author_sort Feng, Renjian
collection PubMed
description The total harmonic distortion (THD) index and its calculation methods are presented to calibrate the sinusoidal motion of the low-frequency angular acceleration rotary table (LFAART) and make up the incomprehensive evaluation based on the angular acceleration amplitude and frequency error indexes. The THD is calculated from two measurement schemes: a unique scheme combining the optical shaft encoder and the laser triangulation sensor and a regular scheme using the fiber optical gyroscope (FOG). An improved reversing moments recognition method is presented to upgrade the accuracy of solving the angular motion amplitude based on optical shaft encoder output. The field experiment shows that the difference in the THD values achieved using the combining scheme and FOG is within 0.11% when the signal-to-noise ratio of the FOG signal is higher than 7.7 dB, indicating the accuracy of the proposed methods and the feasibility of taking THD as the index.
format Online
Article
Text
id pubmed-10221667
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102216672023-05-28 Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table Feng, Renjian Yan, Jiaxuan Wu, Yinfeng Yu, Ning Yin, Xudong Sensors (Basel) Communication The total harmonic distortion (THD) index and its calculation methods are presented to calibrate the sinusoidal motion of the low-frequency angular acceleration rotary table (LFAART) and make up the incomprehensive evaluation based on the angular acceleration amplitude and frequency error indexes. The THD is calculated from two measurement schemes: a unique scheme combining the optical shaft encoder and the laser triangulation sensor and a regular scheme using the fiber optical gyroscope (FOG). An improved reversing moments recognition method is presented to upgrade the accuracy of solving the angular motion amplitude based on optical shaft encoder output. The field experiment shows that the difference in the THD values achieved using the combining scheme and FOG is within 0.11% when the signal-to-noise ratio of the FOG signal is higher than 7.7 dB, indicating the accuracy of the proposed methods and the feasibility of taking THD as the index. MDPI 2023-05-18 /pmc/articles/PMC10221667/ /pubmed/37430788 http://dx.doi.org/10.3390/s23104876 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Communication
Feng, Renjian
Yan, Jiaxuan
Wu, Yinfeng
Yu, Ning
Yin, Xudong
Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
title Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
title_full Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
title_fullStr Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
title_full_unstemmed Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
title_short Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
title_sort methods for comprehensive calibration of a low-frequency angular acceleration rotary table
topic Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221667/
https://www.ncbi.nlm.nih.gov/pubmed/37430788
http://dx.doi.org/10.3390/s23104876
work_keys_str_mv AT fengrenjian methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable
AT yanjiaxuan methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable
AT wuyinfeng methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable
AT yuning methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable
AT yinxudong methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable