Cargando…
Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table
The total harmonic distortion (THD) index and its calculation methods are presented to calibrate the sinusoidal motion of the low-frequency angular acceleration rotary table (LFAART) and make up the incomprehensive evaluation based on the angular acceleration amplitude and frequency error indexes. T...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221667/ https://www.ncbi.nlm.nih.gov/pubmed/37430788 http://dx.doi.org/10.3390/s23104876 |
_version_ | 1785049511027015680 |
---|---|
author | Feng, Renjian Yan, Jiaxuan Wu, Yinfeng Yu, Ning Yin, Xudong |
author_facet | Feng, Renjian Yan, Jiaxuan Wu, Yinfeng Yu, Ning Yin, Xudong |
author_sort | Feng, Renjian |
collection | PubMed |
description | The total harmonic distortion (THD) index and its calculation methods are presented to calibrate the sinusoidal motion of the low-frequency angular acceleration rotary table (LFAART) and make up the incomprehensive evaluation based on the angular acceleration amplitude and frequency error indexes. The THD is calculated from two measurement schemes: a unique scheme combining the optical shaft encoder and the laser triangulation sensor and a regular scheme using the fiber optical gyroscope (FOG). An improved reversing moments recognition method is presented to upgrade the accuracy of solving the angular motion amplitude based on optical shaft encoder output. The field experiment shows that the difference in the THD values achieved using the combining scheme and FOG is within 0.11% when the signal-to-noise ratio of the FOG signal is higher than 7.7 dB, indicating the accuracy of the proposed methods and the feasibility of taking THD as the index. |
format | Online Article Text |
id | pubmed-10221667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102216672023-05-28 Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table Feng, Renjian Yan, Jiaxuan Wu, Yinfeng Yu, Ning Yin, Xudong Sensors (Basel) Communication The total harmonic distortion (THD) index and its calculation methods are presented to calibrate the sinusoidal motion of the low-frequency angular acceleration rotary table (LFAART) and make up the incomprehensive evaluation based on the angular acceleration amplitude and frequency error indexes. The THD is calculated from two measurement schemes: a unique scheme combining the optical shaft encoder and the laser triangulation sensor and a regular scheme using the fiber optical gyroscope (FOG). An improved reversing moments recognition method is presented to upgrade the accuracy of solving the angular motion amplitude based on optical shaft encoder output. The field experiment shows that the difference in the THD values achieved using the combining scheme and FOG is within 0.11% when the signal-to-noise ratio of the FOG signal is higher than 7.7 dB, indicating the accuracy of the proposed methods and the feasibility of taking THD as the index. MDPI 2023-05-18 /pmc/articles/PMC10221667/ /pubmed/37430788 http://dx.doi.org/10.3390/s23104876 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Feng, Renjian Yan, Jiaxuan Wu, Yinfeng Yu, Ning Yin, Xudong Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table |
title | Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table |
title_full | Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table |
title_fullStr | Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table |
title_full_unstemmed | Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table |
title_short | Methods for Comprehensive Calibration of a Low-Frequency Angular Acceleration Rotary Table |
title_sort | methods for comprehensive calibration of a low-frequency angular acceleration rotary table |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221667/ https://www.ncbi.nlm.nih.gov/pubmed/37430788 http://dx.doi.org/10.3390/s23104876 |
work_keys_str_mv | AT fengrenjian methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable AT yanjiaxuan methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable AT wuyinfeng methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable AT yuning methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable AT yinxudong methodsforcomprehensivecalibrationofalowfrequencyangularaccelerationrotarytable |