Cargando…
Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221782/ https://www.ncbi.nlm.nih.gov/pubmed/37241130 http://dx.doi.org/10.3390/medicina59050899 |
_version_ | 1785049538623438848 |
---|---|
author | Dong, Jing Yao, Jinhan Chang, Shuimiao Kanclerz, Piotr Khoramnia, Ramin Wang, Xiaogang |
author_facet | Dong, Jing Yao, Jinhan Chang, Shuimiao Kanclerz, Piotr Khoramnia, Ramin Wang, Xiaogang |
author_sort | Dong, Jing |
collection | PubMed |
description | Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0°–180°, 30°–210°, 60°–240°, 90°–270°, 120°–300°, and 150°–330°) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson’s correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 ± 0.08 mm (p = 0.005) and 0.21 ± 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 ± 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW. |
format | Online Article Text |
id | pubmed-10221782 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102217822023-05-28 Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography Dong, Jing Yao, Jinhan Chang, Shuimiao Kanclerz, Piotr Khoramnia, Ramin Wang, Xiaogang Medicina (Kaunas) Article Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0°–180°, 30°–210°, 60°–240°, 90°–270°, 120°–300°, and 150°–330°) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson’s correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 ± 0.08 mm (p = 0.005) and 0.21 ± 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 ± 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW. MDPI 2023-05-08 /pmc/articles/PMC10221782/ /pubmed/37241130 http://dx.doi.org/10.3390/medicina59050899 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dong, Jing Yao, Jinhan Chang, Shuimiao Kanclerz, Piotr Khoramnia, Ramin Wang, Xiaogang Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography |
title | Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography |
title_full | Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography |
title_fullStr | Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography |
title_full_unstemmed | Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography |
title_short | Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography |
title_sort | evaluation of ocular diameter parameters using swept-source optical coherence tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221782/ https://www.ncbi.nlm.nih.gov/pubmed/37241130 http://dx.doi.org/10.3390/medicina59050899 |
work_keys_str_mv | AT dongjing evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography AT yaojinhan evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography AT changshuimiao evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography AT kanclerzpiotr evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography AT khoramniaramin evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography AT wangxiaogang evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography |