Cargando…

Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography

Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source...

Descripción completa

Detalles Bibliográficos
Autores principales: Dong, Jing, Yao, Jinhan, Chang, Shuimiao, Kanclerz, Piotr, Khoramnia, Ramin, Wang, Xiaogang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221782/
https://www.ncbi.nlm.nih.gov/pubmed/37241130
http://dx.doi.org/10.3390/medicina59050899
_version_ 1785049538623438848
author Dong, Jing
Yao, Jinhan
Chang, Shuimiao
Kanclerz, Piotr
Khoramnia, Ramin
Wang, Xiaogang
author_facet Dong, Jing
Yao, Jinhan
Chang, Shuimiao
Kanclerz, Piotr
Khoramnia, Ramin
Wang, Xiaogang
author_sort Dong, Jing
collection PubMed
description Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0°–180°, 30°–210°, 60°–240°, 90°–270°, 120°–300°, and 150°–330°) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson’s correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 ± 0.08 mm (p = 0.005) and 0.21 ± 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 ± 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW.
format Online
Article
Text
id pubmed-10221782
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102217822023-05-28 Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography Dong, Jing Yao, Jinhan Chang, Shuimiao Kanclerz, Piotr Khoramnia, Ramin Wang, Xiaogang Medicina (Kaunas) Article Purpose: To investigate the iridocorneal angle-to-angle (ATA), sclera spur-to-sclera spur (STS), and white-to-white (WTW) ocular diameters and their potential influence on anterior chamber intraocular lens (ACIOL) and implantable collamer lens (ICL) sizing in Chinese subjects by using a swept-source optical coherence tomography system (SS-OCT). Design: A retrospective, observational, cross-sectional study. Methods: In 60 right eyes (60 subjects), the ATA, STS, and WTW were measured in six axes (0°–180°, 30°–210°, 60°–240°, 90°–270°, 120°–300°, and 150°–330°) using SS-OCT. The ACIOL and ICL sizes were calculated based on horizontal and vertical axes anterior segment data. A paired sample t-test was used to test the differences in each parameter across the six axes, the potential difference between each pair of parameters in a given axis, and the artificial lens size difference between the horizontal and vertical directions. Pearson’s correlation analysis was used to determine the potential correlation between age and AL, WTW, STS, and ATA distances. Results: ATA and STS were the longest on the vertical and shortest on the horizontal axis, while WTW was similar on both axes. These three parameters differed only in the vertical axis (F = 4.910, p = 0.008). ATA and STS were by 0.23 ± 0.08 mm (p = 0.005) and 0.21 ± 0.08 mm wider (p = 0.010) than WTW, respectively. ICL size was 0.27 ± 0.23 mm smaller when based on the horizontal than on the vertical axis parameters (p < 0.001), while ACIOL remained similar (p = 0.709). Age correlated negatively and axial length positively with all measured values. ATA, STS, and WTW correlated positively in the same axis (all p < 0.001). Conclusions: ATA and STS were longer in the vertical than in the horizontal direction, while WTW measurements remained similar. ATA and STS diameters more accurately depicted anatomic relationships for phakic IOL sizing than WTW. MDPI 2023-05-08 /pmc/articles/PMC10221782/ /pubmed/37241130 http://dx.doi.org/10.3390/medicina59050899 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Dong, Jing
Yao, Jinhan
Chang, Shuimiao
Kanclerz, Piotr
Khoramnia, Ramin
Wang, Xiaogang
Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
title Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
title_full Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
title_fullStr Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
title_full_unstemmed Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
title_short Evaluation of Ocular Diameter Parameters Using Swept-Source Optical Coherence Tomography
title_sort evaluation of ocular diameter parameters using swept-source optical coherence tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221782/
https://www.ncbi.nlm.nih.gov/pubmed/37241130
http://dx.doi.org/10.3390/medicina59050899
work_keys_str_mv AT dongjing evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography
AT yaojinhan evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography
AT changshuimiao evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography
AT kanclerzpiotr evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography
AT khoramniaramin evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography
AT wangxiaogang evaluationofoculardiameterparametersusingsweptsourceopticalcoherencetomography