The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System
The implementation of an energy storage system (ESS) as a container-type package is common due to its ease of installation, management, and safety. The control of the operating environment of an ESS mainly considers the temperature rise due to the heat generated through the battery operation. Howeve...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221917/ https://www.ncbi.nlm.nih.gov/pubmed/37430628 http://dx.doi.org/10.3390/s23104715 |
_version_ | 1785049571285532672 |
---|---|
author | Park, Hye-Yeon Lee, Jin-Wook Park, Sung-Won Son, Sung-Yong |
author_facet | Park, Hye-Yeon Lee, Jin-Wook Park, Sung-Won Son, Sung-Yong |
author_sort | Park, Hye-Yeon |
collection | PubMed |
description | The implementation of an energy storage system (ESS) as a container-type package is common due to its ease of installation, management, and safety. The control of the operating environment of an ESS mainly considers the temperature rise due to the heat generated through the battery operation. However, the relative humidity of the container often increases by over 75% in many cases because of the operation of the air conditioner which pursues temperature-first control. Humidity is a major factor which can cause safety issues such as fires owing to insulation breakdown caused by condensation. However, the importance of humidity control in ESS is underestimated compared to temperature control. In this study, temperature and humidity monitoring and management issues were addressed for a container-type ESS by building sensor-based monitoring and control systems. Furthermore, a rule-based air conditioner control algorithm was proposed for temperature and humidity management. A case study was conducted to compare the conventional and proposed control algorithms and verify the feasibility of the proposed algorithm. The results showed that the proposed algorithm reduced the average humidity by 11.4% compared to the value achieved with the existing temperature control method while also maintaining the temperature. |
format | Online Article Text |
id | pubmed-10221917 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102219172023-05-28 The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System Park, Hye-Yeon Lee, Jin-Wook Park, Sung-Won Son, Sung-Yong Sensors (Basel) Article The implementation of an energy storage system (ESS) as a container-type package is common due to its ease of installation, management, and safety. The control of the operating environment of an ESS mainly considers the temperature rise due to the heat generated through the battery operation. However, the relative humidity of the container often increases by over 75% in many cases because of the operation of the air conditioner which pursues temperature-first control. Humidity is a major factor which can cause safety issues such as fires owing to insulation breakdown caused by condensation. However, the importance of humidity control in ESS is underestimated compared to temperature control. In this study, temperature and humidity monitoring and management issues were addressed for a container-type ESS by building sensor-based monitoring and control systems. Furthermore, a rule-based air conditioner control algorithm was proposed for temperature and humidity management. A case study was conducted to compare the conventional and proposed control algorithms and verify the feasibility of the proposed algorithm. The results showed that the proposed algorithm reduced the average humidity by 11.4% compared to the value achieved with the existing temperature control method while also maintaining the temperature. MDPI 2023-05-12 /pmc/articles/PMC10221917/ /pubmed/37430628 http://dx.doi.org/10.3390/s23104715 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Park, Hye-Yeon Lee, Jin-Wook Park, Sung-Won Son, Sung-Yong The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System |
title | The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System |
title_full | The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System |
title_fullStr | The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System |
title_full_unstemmed | The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System |
title_short | The Monitoring and Management of an Operating Environment to Enhance the Safety of a Container-Type Energy Storage System |
title_sort | monitoring and management of an operating environment to enhance the safety of a container-type energy storage system |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10221917/ https://www.ncbi.nlm.nih.gov/pubmed/37430628 http://dx.doi.org/10.3390/s23104715 |
work_keys_str_mv | AT parkhyeyeon themonitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT leejinwook themonitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT parksungwon themonitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT sonsungyong themonitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT parkhyeyeon monitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT leejinwook monitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT parksungwon monitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem AT sonsungyong monitoringandmanagementofanoperatingenvironmenttoenhancethesafetyofacontainertypeenergystoragesystem |