Cargando…

Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software

Introduction: Electrode length selection based on case-related cochlear parameters is becoming a standard pre-operative step for cochlear implantation. The manual measurement of the parameters is often time-consuming and may lead to inconsistencies. Our work aimed to evaluate a novel, automatic meas...

Descripción completa

Detalles Bibliográficos
Autores principales: Paouris, Dimitrios, Kunzo, Samuel, Goljerová, Irina
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222564/
https://www.ncbi.nlm.nih.gov/pubmed/37240975
http://dx.doi.org/10.3390/jpm13050805
_version_ 1785049729274478592
author Paouris, Dimitrios
Kunzo, Samuel
Goljerová, Irina
author_facet Paouris, Dimitrios
Kunzo, Samuel
Goljerová, Irina
author_sort Paouris, Dimitrios
collection PubMed
description Introduction: Electrode length selection based on case-related cochlear parameters is becoming a standard pre-operative step for cochlear implantation. The manual measurement of the parameters is often time-consuming and may lead to inconsistencies. Our work aimed to evaluate a novel, automatic measurement method. Materials and Methods: A retrospective evaluation of pre-operative HRCT images of 109 ears (56 patients) was conducted, using a development version of the OTOPLAN(®) software. Inter-rater (intraclass) reliability and execution time were assessed for manual (surgeons R1 and R2) vs. automatic (AUTO) results. The analysis included A-Value (Diameter), B-Value (Width), H-Value (Height), and CDLOC-length (Cochlear Duct Length at Organ of Corti/Basilar membrane). Results: The measurement time was reduced from approximately 7 min ± 2 (min) (manual) to 1 min (AUTO). Cochlear parameters in mm (mean ± SD) for R1, R2 and AUTO, respectively, were A-value: 9.00 ± 0.40, 8.98 ± 0.40 and 9.16 ± 0.36; B-value: 6.81 ± 0.34, 6.71 ± 0.35 and 6.70 ± 0.40; H-value: 3.98 ± 0.25, 3.85 ± 0.25 and 3.76 ± 0.22; and the mean CDLoc-length: 35.64 ± 1.70, 35.20 ± 1.71 and 35.47 ± 1.87. AUTO CDLOC measurements were not significantly different compared to R1 and R2 (H0: Rx CDLOC = AUTO CDLOC: p = 0.831, p = 0.242, respectively), and the calculated intraclass correlation coefficient (ICC) for CDLOC was 0.9 (95% CI: 0.85, 0.932) for R1 vs. AUTO; 0.90 (95% CI: 0.85, 0.932) for R2 vs. AUTO; and 0.893 (95% CI: 0.809, 0.935) for R1 vs. R2. Conclusions: We observed excellent inter-rater reliability, a high agreement of outcomes, and reduced execution time using the AUTO method.
format Online
Article
Text
id pubmed-10222564
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102225642023-05-28 Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software Paouris, Dimitrios Kunzo, Samuel Goljerová, Irina J Pers Med Project Report Introduction: Electrode length selection based on case-related cochlear parameters is becoming a standard pre-operative step for cochlear implantation. The manual measurement of the parameters is often time-consuming and may lead to inconsistencies. Our work aimed to evaluate a novel, automatic measurement method. Materials and Methods: A retrospective evaluation of pre-operative HRCT images of 109 ears (56 patients) was conducted, using a development version of the OTOPLAN(®) software. Inter-rater (intraclass) reliability and execution time were assessed for manual (surgeons R1 and R2) vs. automatic (AUTO) results. The analysis included A-Value (Diameter), B-Value (Width), H-Value (Height), and CDLOC-length (Cochlear Duct Length at Organ of Corti/Basilar membrane). Results: The measurement time was reduced from approximately 7 min ± 2 (min) (manual) to 1 min (AUTO). Cochlear parameters in mm (mean ± SD) for R1, R2 and AUTO, respectively, were A-value: 9.00 ± 0.40, 8.98 ± 0.40 and 9.16 ± 0.36; B-value: 6.81 ± 0.34, 6.71 ± 0.35 and 6.70 ± 0.40; H-value: 3.98 ± 0.25, 3.85 ± 0.25 and 3.76 ± 0.22; and the mean CDLoc-length: 35.64 ± 1.70, 35.20 ± 1.71 and 35.47 ± 1.87. AUTO CDLOC measurements were not significantly different compared to R1 and R2 (H0: Rx CDLOC = AUTO CDLOC: p = 0.831, p = 0.242, respectively), and the calculated intraclass correlation coefficient (ICC) for CDLOC was 0.9 (95% CI: 0.85, 0.932) for R1 vs. AUTO; 0.90 (95% CI: 0.85, 0.932) for R2 vs. AUTO; and 0.893 (95% CI: 0.809, 0.935) for R1 vs. R2. Conclusions: We observed excellent inter-rater reliability, a high agreement of outcomes, and reduced execution time using the AUTO method. MDPI 2023-05-08 /pmc/articles/PMC10222564/ /pubmed/37240975 http://dx.doi.org/10.3390/jpm13050805 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Project Report
Paouris, Dimitrios
Kunzo, Samuel
Goljerová, Irina
Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software
title Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software
title_full Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software
title_fullStr Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software
title_full_unstemmed Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software
title_short Validation of Automatic Cochlear Measurements Using OTOPLAN(®) Software
title_sort validation of automatic cochlear measurements using otoplan(®) software
topic Project Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222564/
https://www.ncbi.nlm.nih.gov/pubmed/37240975
http://dx.doi.org/10.3390/jpm13050805
work_keys_str_mv AT paourisdimitrios validationofautomaticcochlearmeasurementsusingotoplansoftware
AT kunzosamuel validationofautomaticcochlearmeasurementsusingotoplansoftware
AT goljerovairina validationofautomaticcochlearmeasurementsusingotoplansoftware