Cargando…
Chamber Protection of Zinc with Ethylhexanoic Acid
Chamber protection is a promising and quickly developing method of vapor-phase protection of metals against atmospheric corrosion by inhibitors. It was shown that chamber treatment with 2-ethylhexanoic acid (EHA) efficiently inhibits the initiation of zinc corrosion. The optimum conditions (temperat...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222723/ https://www.ncbi.nlm.nih.gov/pubmed/37241306 http://dx.doi.org/10.3390/ma16103679 |
_version_ | 1785049767786577920 |
---|---|
author | Goncharova, Olga A. Luchkin, Andrey Yu. Andreev, Nickolay N. Grafov, Oleg Yu. Makarova, Olga S. Kuznetsov, Ilya A. Vesely, Sergey S. |
author_facet | Goncharova, Olga A. Luchkin, Andrey Yu. Andreev, Nickolay N. Grafov, Oleg Yu. Makarova, Olga S. Kuznetsov, Ilya A. Vesely, Sergey S. |
author_sort | Goncharova, Olga A. |
collection | PubMed |
description | Chamber protection is a promising and quickly developing method of vapor-phase protection of metals against atmospheric corrosion by inhibitors. It was shown that chamber treatment with 2-ethylhexanoic acid (EHA) efficiently inhibits the initiation of zinc corrosion. The optimum conditions (temperature and duration) of zinc treatment with vapors of this compound were determined. If these conditions are met, adsorption films of EHA with thicknesses up to 100 nm are formed on the metal surface. It was found that their protective properties increase during the first day as zinc is exposed to air after chamber treatment. The anticorrosive action of adsorption films is due both to the surface being shielded from the corrosive environment and to the inhibition of corrosion processes on the active surface of the metal. Corrosion inhibition was caused by the ability of EHA to convert zinc to the passive state and inhibit its local anionic depassivation. |
format | Online Article Text |
id | pubmed-10222723 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102227232023-05-28 Chamber Protection of Zinc with Ethylhexanoic Acid Goncharova, Olga A. Luchkin, Andrey Yu. Andreev, Nickolay N. Grafov, Oleg Yu. Makarova, Olga S. Kuznetsov, Ilya A. Vesely, Sergey S. Materials (Basel) Article Chamber protection is a promising and quickly developing method of vapor-phase protection of metals against atmospheric corrosion by inhibitors. It was shown that chamber treatment with 2-ethylhexanoic acid (EHA) efficiently inhibits the initiation of zinc corrosion. The optimum conditions (temperature and duration) of zinc treatment with vapors of this compound were determined. If these conditions are met, adsorption films of EHA with thicknesses up to 100 nm are formed on the metal surface. It was found that their protective properties increase during the first day as zinc is exposed to air after chamber treatment. The anticorrosive action of adsorption films is due both to the surface being shielded from the corrosive environment and to the inhibition of corrosion processes on the active surface of the metal. Corrosion inhibition was caused by the ability of EHA to convert zinc to the passive state and inhibit its local anionic depassivation. MDPI 2023-05-11 /pmc/articles/PMC10222723/ /pubmed/37241306 http://dx.doi.org/10.3390/ma16103679 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Goncharova, Olga A. Luchkin, Andrey Yu. Andreev, Nickolay N. Grafov, Oleg Yu. Makarova, Olga S. Kuznetsov, Ilya A. Vesely, Sergey S. Chamber Protection of Zinc with Ethylhexanoic Acid |
title | Chamber Protection of Zinc with Ethylhexanoic Acid |
title_full | Chamber Protection of Zinc with Ethylhexanoic Acid |
title_fullStr | Chamber Protection of Zinc with Ethylhexanoic Acid |
title_full_unstemmed | Chamber Protection of Zinc with Ethylhexanoic Acid |
title_short | Chamber Protection of Zinc with Ethylhexanoic Acid |
title_sort | chamber protection of zinc with ethylhexanoic acid |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222723/ https://www.ncbi.nlm.nih.gov/pubmed/37241306 http://dx.doi.org/10.3390/ma16103679 |
work_keys_str_mv | AT goncharovaolgaa chamberprotectionofzincwithethylhexanoicacid AT luchkinandreyyu chamberprotectionofzincwithethylhexanoicacid AT andreevnickolayn chamberprotectionofzincwithethylhexanoicacid AT grafovolegyu chamberprotectionofzincwithethylhexanoicacid AT makarovaolgas chamberprotectionofzincwithethylhexanoicacid AT kuznetsovilyaa chamberprotectionofzincwithethylhexanoicacid AT veselysergeys chamberprotectionofzincwithethylhexanoicacid |