Cargando…

A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System

The potential for nanoparticles to cause harm to human health and the environment is correlated with their biodurability in the human body and persistence in the environment. Dissolution testing serves to predict biodurability and nanoparticle environmental persistence. In this study, dissolution te...

Descripción completa

Detalles Bibliográficos
Autores principales: Mbanga, Odwa, Cukrowska, Ewa, Gulumian, Mary
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222824/
https://www.ncbi.nlm.nih.gov/pubmed/37242069
http://dx.doi.org/10.3390/nano13101653
_version_ 1785049793130659840
author Mbanga, Odwa
Cukrowska, Ewa
Gulumian, Mary
author_facet Mbanga, Odwa
Cukrowska, Ewa
Gulumian, Mary
author_sort Mbanga, Odwa
collection PubMed
description The potential for nanoparticles to cause harm to human health and the environment is correlated with their biodurability in the human body and persistence in the environment. Dissolution testing serves to predict biodurability and nanoparticle environmental persistence. In this study, dissolution testing using the continuous flow through system was used to investigate the biodurability and persistence of gold nanoparticles (AuNPs), silver nanoparticles (AgNPs) and titanium dioxide nanoparticles (TiO(2) NPs) in five different simulated biological fluids and two synthetic environmental media to predict their behaviour in real life situations. This study examined the physicochemical properties and agglomeration state of gold, silver and titanium dioxide nanoparticles before and after dissolution tests using three different techniques (UV-vis, XRD and TEM). The UV-vis spectra revealed that all three nanoparticles shifted to higher wavelengths after being exposed to simulated fluids. The titanium powder was found to be mixed with both rutile and anatase, according to XRD examination. The average diameter of gold nanoparticles was 14 nm, silver nanoparticles were 10 nm and titanium dioxide nanoparticles were 25 nm, according to TEM images. The gold and silver nanoparticles were observed to be spherical, but the titanium dioxide nanoparticles were irregular in shape, with some being spherical. The level of dissolved nanoparticles in simulated acidic media was higher in magnitude compared to that dissolved in simulated alkaline media. The results obtained via the continuous flow through dissolution system also displayed very significant dissolution rates. For TiO(2) NPs the calculated half-times were in the range of 13–14 days, followed by AuNPs ranging between 4–12 days, significantly longer if compared to the half-times of AgNPs ranging between 2–7 days. AuNPs and TiO(2) NPs were characterized by low dissolution rates therefore are expected to be (bio)durable in physiological surroundings and persistent in the environment thus, they might impose long-term effects on humans and the environment. In contrast, AgNPs have high dissolution rates and not (bio)durable and hence may cause short-term effects. The results suggest a hierarchy of biodurability and persistence of TiO(2) NPs > AuNPs > AgNPs. It is recommended that nanoparticle product developers should follow the test guidelines stipulated by the OECD to ensure product safety for use before it is taken to the market.
format Online
Article
Text
id pubmed-10222824
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102228242023-05-28 A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System Mbanga, Odwa Cukrowska, Ewa Gulumian, Mary Nanomaterials (Basel) Article The potential for nanoparticles to cause harm to human health and the environment is correlated with their biodurability in the human body and persistence in the environment. Dissolution testing serves to predict biodurability and nanoparticle environmental persistence. In this study, dissolution testing using the continuous flow through system was used to investigate the biodurability and persistence of gold nanoparticles (AuNPs), silver nanoparticles (AgNPs) and titanium dioxide nanoparticles (TiO(2) NPs) in five different simulated biological fluids and two synthetic environmental media to predict their behaviour in real life situations. This study examined the physicochemical properties and agglomeration state of gold, silver and titanium dioxide nanoparticles before and after dissolution tests using three different techniques (UV-vis, XRD and TEM). The UV-vis spectra revealed that all three nanoparticles shifted to higher wavelengths after being exposed to simulated fluids. The titanium powder was found to be mixed with both rutile and anatase, according to XRD examination. The average diameter of gold nanoparticles was 14 nm, silver nanoparticles were 10 nm and titanium dioxide nanoparticles were 25 nm, according to TEM images. The gold and silver nanoparticles were observed to be spherical, but the titanium dioxide nanoparticles were irregular in shape, with some being spherical. The level of dissolved nanoparticles in simulated acidic media was higher in magnitude compared to that dissolved in simulated alkaline media. The results obtained via the continuous flow through dissolution system also displayed very significant dissolution rates. For TiO(2) NPs the calculated half-times were in the range of 13–14 days, followed by AuNPs ranging between 4–12 days, significantly longer if compared to the half-times of AgNPs ranging between 2–7 days. AuNPs and TiO(2) NPs were characterized by low dissolution rates therefore are expected to be (bio)durable in physiological surroundings and persistent in the environment thus, they might impose long-term effects on humans and the environment. In contrast, AgNPs have high dissolution rates and not (bio)durable and hence may cause short-term effects. The results suggest a hierarchy of biodurability and persistence of TiO(2) NPs > AuNPs > AgNPs. It is recommended that nanoparticle product developers should follow the test guidelines stipulated by the OECD to ensure product safety for use before it is taken to the market. MDPI 2023-05-16 /pmc/articles/PMC10222824/ /pubmed/37242069 http://dx.doi.org/10.3390/nano13101653 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Mbanga, Odwa
Cukrowska, Ewa
Gulumian, Mary
A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System
title A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System
title_full A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System
title_fullStr A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System
title_full_unstemmed A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System
title_short A Comparative Study of the Biodurability and Persistence of Gold, Silver and Titanium Dioxide Nanoparticles Using the Continuous Flow through System
title_sort comparative study of the biodurability and persistence of gold, silver and titanium dioxide nanoparticles using the continuous flow through system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222824/
https://www.ncbi.nlm.nih.gov/pubmed/37242069
http://dx.doi.org/10.3390/nano13101653
work_keys_str_mv AT mbangaodwa acomparativestudyofthebiodurabilityandpersistenceofgoldsilverandtitaniumdioxidenanoparticlesusingthecontinuousflowthroughsystem
AT cukrowskaewa acomparativestudyofthebiodurabilityandpersistenceofgoldsilverandtitaniumdioxidenanoparticlesusingthecontinuousflowthroughsystem
AT gulumianmary acomparativestudyofthebiodurabilityandpersistenceofgoldsilverandtitaniumdioxidenanoparticlesusingthecontinuousflowthroughsystem
AT mbangaodwa comparativestudyofthebiodurabilityandpersistenceofgoldsilverandtitaniumdioxidenanoparticlesusingthecontinuousflowthroughsystem
AT cukrowskaewa comparativestudyofthebiodurabilityandpersistenceofgoldsilverandtitaniumdioxidenanoparticlesusingthecontinuousflowthroughsystem
AT gulumianmary comparativestudyofthebiodurabilityandpersistenceofgoldsilverandtitaniumdioxidenanoparticlesusingthecontinuousflowthroughsystem