Cargando…

The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI

Background: Stent enhancement techniques allow adequate visualization of stent deformation or incomplete stent expansion at the ostium of the side branch. Measuring the stent enhancement side branch length (SESBL) could reflect procedural success in terms of optimal stent expansion and apposition wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Moț, Ștefan Dan Cezar, Șerban, Adela Mihaela, Dădârlat-Pop, Alexandra, Tomoaia, Raluca, Pop, Dana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222991/
https://www.ncbi.nlm.nih.gov/pubmed/37240961
http://dx.doi.org/10.3390/jpm13050791
_version_ 1785049832852815872
author Moț, Ștefan Dan Cezar
Șerban, Adela Mihaela
Dădârlat-Pop, Alexandra
Tomoaia, Raluca
Pop, Dana
author_facet Moț, Ștefan Dan Cezar
Șerban, Adela Mihaela
Dădârlat-Pop, Alexandra
Tomoaia, Raluca
Pop, Dana
author_sort Moț, Ștefan Dan Cezar
collection PubMed
description Background: Stent enhancement techniques allow adequate visualization of stent deformation or incomplete stent expansion at the ostium of the side branch. Measuring the stent enhancement side branch length (SESBL) could reflect procedural success in terms of optimal stent expansion and apposition with better long-term outcomes. A longer SESBL may reflect a better stent apposition at the polygon of confluence and at the side branch (SB) ostium. Methods: We evaluated 162 patients receiving the left main (LM) provisional one-stent technique and measured the SESBL, dividing them into two groups: SESBL≤ 2.0 mm and SESBL > 2.0 mm. Results: The mean SESBL was 2.0 ± 1.2 mm. More than half of the bifurcations had both main and side branch lesions (Medina 1-1-1) (84 patients, 51.9%) and the length of the SB disease was 5.2 ±1.8 mm. Kissing balloon inflation (KBI) was performed in 49 patients (30.2%). During follow-up (12 months), there was a significantly higher rate of cardiac death in the SESBL ≤ 2.0 mm group (p = 0.02) but no significant difference in all major adverse cardiovascular events (MACEs) (p = 0.7). KBI did not influence the outcomes (p = 0.3). Conclusion: Suboptimal SESBL is positively correlated with worse outcomes and SB compromise. This novel sign could aid the LM operator to assess the level of stent expansion at the ostium of the SB in the absence of intracoronary imaging.
format Online
Article
Text
id pubmed-10222991
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102229912023-05-28 The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI Moț, Ștefan Dan Cezar Șerban, Adela Mihaela Dădârlat-Pop, Alexandra Tomoaia, Raluca Pop, Dana J Pers Med Article Background: Stent enhancement techniques allow adequate visualization of stent deformation or incomplete stent expansion at the ostium of the side branch. Measuring the stent enhancement side branch length (SESBL) could reflect procedural success in terms of optimal stent expansion and apposition with better long-term outcomes. A longer SESBL may reflect a better stent apposition at the polygon of confluence and at the side branch (SB) ostium. Methods: We evaluated 162 patients receiving the left main (LM) provisional one-stent technique and measured the SESBL, dividing them into two groups: SESBL≤ 2.0 mm and SESBL > 2.0 mm. Results: The mean SESBL was 2.0 ± 1.2 mm. More than half of the bifurcations had both main and side branch lesions (Medina 1-1-1) (84 patients, 51.9%) and the length of the SB disease was 5.2 ±1.8 mm. Kissing balloon inflation (KBI) was performed in 49 patients (30.2%). During follow-up (12 months), there was a significantly higher rate of cardiac death in the SESBL ≤ 2.0 mm group (p = 0.02) but no significant difference in all major adverse cardiovascular events (MACEs) (p = 0.7). KBI did not influence the outcomes (p = 0.3). Conclusion: Suboptimal SESBL is positively correlated with worse outcomes and SB compromise. This novel sign could aid the LM operator to assess the level of stent expansion at the ostium of the SB in the absence of intracoronary imaging. MDPI 2023-05-03 /pmc/articles/PMC10222991/ /pubmed/37240961 http://dx.doi.org/10.3390/jpm13050791 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Moț, Ștefan Dan Cezar
Șerban, Adela Mihaela
Dădârlat-Pop, Alexandra
Tomoaia, Raluca
Pop, Dana
The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
title The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
title_full The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
title_fullStr The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
title_full_unstemmed The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
title_short The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
title_sort degree of stent apposition measured by stent enhancement at the level of the side branch as a novel predictor of procedural success in left main pci
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222991/
https://www.ncbi.nlm.nih.gov/pubmed/37240961
http://dx.doi.org/10.3390/jpm13050791
work_keys_str_mv AT motstefandancezar thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT serbanadelamihaela thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT dadarlatpopalexandra thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT tomoaiaraluca thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT popdana thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT motstefandancezar degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT serbanadelamihaela degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT dadarlatpopalexandra degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT tomoaiaraluca degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci
AT popdana degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci