Cargando…
The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI
Background: Stent enhancement techniques allow adequate visualization of stent deformation or incomplete stent expansion at the ostium of the side branch. Measuring the stent enhancement side branch length (SESBL) could reflect procedural success in terms of optimal stent expansion and apposition wi...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222991/ https://www.ncbi.nlm.nih.gov/pubmed/37240961 http://dx.doi.org/10.3390/jpm13050791 |
_version_ | 1785049832852815872 |
---|---|
author | Moț, Ștefan Dan Cezar Șerban, Adela Mihaela Dădârlat-Pop, Alexandra Tomoaia, Raluca Pop, Dana |
author_facet | Moț, Ștefan Dan Cezar Șerban, Adela Mihaela Dădârlat-Pop, Alexandra Tomoaia, Raluca Pop, Dana |
author_sort | Moț, Ștefan Dan Cezar |
collection | PubMed |
description | Background: Stent enhancement techniques allow adequate visualization of stent deformation or incomplete stent expansion at the ostium of the side branch. Measuring the stent enhancement side branch length (SESBL) could reflect procedural success in terms of optimal stent expansion and apposition with better long-term outcomes. A longer SESBL may reflect a better stent apposition at the polygon of confluence and at the side branch (SB) ostium. Methods: We evaluated 162 patients receiving the left main (LM) provisional one-stent technique and measured the SESBL, dividing them into two groups: SESBL≤ 2.0 mm and SESBL > 2.0 mm. Results: The mean SESBL was 2.0 ± 1.2 mm. More than half of the bifurcations had both main and side branch lesions (Medina 1-1-1) (84 patients, 51.9%) and the length of the SB disease was 5.2 ±1.8 mm. Kissing balloon inflation (KBI) was performed in 49 patients (30.2%). During follow-up (12 months), there was a significantly higher rate of cardiac death in the SESBL ≤ 2.0 mm group (p = 0.02) but no significant difference in all major adverse cardiovascular events (MACEs) (p = 0.7). KBI did not influence the outcomes (p = 0.3). Conclusion: Suboptimal SESBL is positively correlated with worse outcomes and SB compromise. This novel sign could aid the LM operator to assess the level of stent expansion at the ostium of the SB in the absence of intracoronary imaging. |
format | Online Article Text |
id | pubmed-10222991 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102229912023-05-28 The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI Moț, Ștefan Dan Cezar Șerban, Adela Mihaela Dădârlat-Pop, Alexandra Tomoaia, Raluca Pop, Dana J Pers Med Article Background: Stent enhancement techniques allow adequate visualization of stent deformation or incomplete stent expansion at the ostium of the side branch. Measuring the stent enhancement side branch length (SESBL) could reflect procedural success in terms of optimal stent expansion and apposition with better long-term outcomes. A longer SESBL may reflect a better stent apposition at the polygon of confluence and at the side branch (SB) ostium. Methods: We evaluated 162 patients receiving the left main (LM) provisional one-stent technique and measured the SESBL, dividing them into two groups: SESBL≤ 2.0 mm and SESBL > 2.0 mm. Results: The mean SESBL was 2.0 ± 1.2 mm. More than half of the bifurcations had both main and side branch lesions (Medina 1-1-1) (84 patients, 51.9%) and the length of the SB disease was 5.2 ±1.8 mm. Kissing balloon inflation (KBI) was performed in 49 patients (30.2%). During follow-up (12 months), there was a significantly higher rate of cardiac death in the SESBL ≤ 2.0 mm group (p = 0.02) but no significant difference in all major adverse cardiovascular events (MACEs) (p = 0.7). KBI did not influence the outcomes (p = 0.3). Conclusion: Suboptimal SESBL is positively correlated with worse outcomes and SB compromise. This novel sign could aid the LM operator to assess the level of stent expansion at the ostium of the SB in the absence of intracoronary imaging. MDPI 2023-05-03 /pmc/articles/PMC10222991/ /pubmed/37240961 http://dx.doi.org/10.3390/jpm13050791 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Moț, Ștefan Dan Cezar Șerban, Adela Mihaela Dădârlat-Pop, Alexandra Tomoaia, Raluca Pop, Dana The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI |
title | The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI |
title_full | The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI |
title_fullStr | The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI |
title_full_unstemmed | The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI |
title_short | The Degree of Stent Apposition Measured by Stent Enhancement at the Level of the Side Branch as a Novel Predictor of Procedural Success in Left Main PCI |
title_sort | degree of stent apposition measured by stent enhancement at the level of the side branch as a novel predictor of procedural success in left main pci |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10222991/ https://www.ncbi.nlm.nih.gov/pubmed/37240961 http://dx.doi.org/10.3390/jpm13050791 |
work_keys_str_mv | AT motstefandancezar thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT serbanadelamihaela thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT dadarlatpopalexandra thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT tomoaiaraluca thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT popdana thedegreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT motstefandancezar degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT serbanadelamihaela degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT dadarlatpopalexandra degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT tomoaiaraluca degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci AT popdana degreeofstentappositionmeasuredbystentenhancementatthelevelofthesidebranchasanovelpredictorofproceduralsuccessinleftmainpci |