Cargando…
Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation
Transcatheter aortic valve implantation (TAVI) is currently becoming the method of choice in high-risk patients with severe aortic valve stenosis. Post-TAVI complications are more common owing to the increasing use of the method. The majority of TAVI complications derive from concomitant aortic sten...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223010/ https://www.ncbi.nlm.nih.gov/pubmed/37241008 http://dx.doi.org/10.3390/jpm13050838 |
_version_ | 1785049837683605504 |
---|---|
author | Klotzka, Aneta Woźniak, Patrycja Misterski, Marcin Rodzki, Michał Puślecki, Mateusz Jemielity, Marek Grygier, Marek Araszkiewicz, Aleksander Iwańczyk, Sylwia Buczkowski, Piotr |
author_facet | Klotzka, Aneta Woźniak, Patrycja Misterski, Marcin Rodzki, Michał Puślecki, Mateusz Jemielity, Marek Grygier, Marek Araszkiewicz, Aleksander Iwańczyk, Sylwia Buczkowski, Piotr |
author_sort | Klotzka, Aneta |
collection | PubMed |
description | Transcatheter aortic valve implantation (TAVI) is currently becoming the method of choice in high-risk patients with severe aortic valve stenosis. Post-TAVI complications are more common owing to the increasing use of the method. The majority of TAVI complications derive from concomitant aortic stenosis with moderate/severe aortic insufficiency, paravalvular leak, and atrioventricular block. The contemporary TAVI qualification process includes a thorough echocardiography and angio-CT of the aorta, which is crucial in assessing valve measurements, determining the position of the coronary arteries branching from the aorta, and choosing the optimal valve size. We present the case report of an 81-year-old patient admitted to our hospital because of exacerbation of the clinical condition and development of pulmonary edema a few days after TAVI. Despite the reduction of the initial leak, an echocardiographic examination revealed the remaining severe paravalvular aortic leakage. We performed open-heart cardio-thoracic surgery, explanted the TAVI valve, and implanted the biological prosthesis (Edwards Perimount Magna size 25). Introduction of new interventional treatment approaches and the availability of imaging tools have substantially reduced the incidence of significant paravalvular leak and offered a better prognosis for patients undergoing TAVI. |
format | Online Article Text |
id | pubmed-10223010 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102230102023-05-28 Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation Klotzka, Aneta Woźniak, Patrycja Misterski, Marcin Rodzki, Michał Puślecki, Mateusz Jemielity, Marek Grygier, Marek Araszkiewicz, Aleksander Iwańczyk, Sylwia Buczkowski, Piotr J Pers Med Case Report Transcatheter aortic valve implantation (TAVI) is currently becoming the method of choice in high-risk patients with severe aortic valve stenosis. Post-TAVI complications are more common owing to the increasing use of the method. The majority of TAVI complications derive from concomitant aortic stenosis with moderate/severe aortic insufficiency, paravalvular leak, and atrioventricular block. The contemporary TAVI qualification process includes a thorough echocardiography and angio-CT of the aorta, which is crucial in assessing valve measurements, determining the position of the coronary arteries branching from the aorta, and choosing the optimal valve size. We present the case report of an 81-year-old patient admitted to our hospital because of exacerbation of the clinical condition and development of pulmonary edema a few days after TAVI. Despite the reduction of the initial leak, an echocardiographic examination revealed the remaining severe paravalvular aortic leakage. We performed open-heart cardio-thoracic surgery, explanted the TAVI valve, and implanted the biological prosthesis (Edwards Perimount Magna size 25). Introduction of new interventional treatment approaches and the availability of imaging tools have substantially reduced the incidence of significant paravalvular leak and offered a better prognosis for patients undergoing TAVI. MDPI 2023-05-16 /pmc/articles/PMC10223010/ /pubmed/37241008 http://dx.doi.org/10.3390/jpm13050838 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Klotzka, Aneta Woźniak, Patrycja Misterski, Marcin Rodzki, Michał Puślecki, Mateusz Jemielity, Marek Grygier, Marek Araszkiewicz, Aleksander Iwańczyk, Sylwia Buczkowski, Piotr Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation |
title | Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation |
title_full | Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation |
title_fullStr | Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation |
title_short | Open-Heart Cardio-Thoracic Biological Valve Replacement Following Complicated Transcatheter Aortic Valve Implantation |
title_sort | open-heart cardio-thoracic biological valve replacement following complicated transcatheter aortic valve implantation |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223010/ https://www.ncbi.nlm.nih.gov/pubmed/37241008 http://dx.doi.org/10.3390/jpm13050838 |
work_keys_str_mv | AT klotzkaaneta openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT wozniakpatrycja openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT misterskimarcin openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT rodzkimichał openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT pusleckimateusz openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT jemielitymarek openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT grygiermarek openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT araszkiewiczaleksander openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT iwanczyksylwia openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation AT buczkowskipiotr openheartcardiothoracicbiologicalvalvereplacementfollowingcomplicatedtranscatheteraorticvalveimplantation |