Cargando…

Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers

The article describes the combination of experimental measurements with mathematical–physics analyses in flow investigation in the chambers of the scintillator detector, which is a part of the environmental scanning electron microscope. The chambers are divided with apertures by small openings that...

Descripción completa

Detalles Bibliográficos
Autores principales: Maxa, Jiří, Neděla, Vilém, Šabacká, Pavla, Binar, Tomáš
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223060/
https://www.ncbi.nlm.nih.gov/pubmed/37430777
http://dx.doi.org/10.3390/s23104861
_version_ 1785049850052608000
author Maxa, Jiří
Neděla, Vilém
Šabacká, Pavla
Binar, Tomáš
author_facet Maxa, Jiří
Neděla, Vilém
Šabacká, Pavla
Binar, Tomáš
author_sort Maxa, Jiří
collection PubMed
description The article describes the combination of experimental measurements with mathematical–physics analyses in flow investigation in the chambers of the scintillator detector, which is a part of the environmental scanning electron microscope. The chambers are divided with apertures by small openings that keep the desirable pressure differences between three chambers: The specimen chamber, the differentially pumped intermediate chamber, and the scintillator chamber. There are conflicting demands on these apertures. On the one hand, the diameter of the apertures must be as big as possible so that they incur minimal losses of the passing secondary electrons. On the other hand, it is possible to magnify the apertures only to a certain extent so the rotary and turbomolecular vacuum pump can maintain the required operating pressures in separate chambers. The article describes the combination of experimental measurement using an absolute pressure sensor and mathematical physics analysis to map all the specifics of the emerging critical supersonic flow in apertures between the chambers. Based on the experiments and their tuned analyses, the most effective variant of combining the sizes of each aperture concerning different operating pressures in the detector is determined. The situation is made more difficult by the described fact that each aperture separates a different pressure gradient, so the gas flow through each aperture has its own characteristics with a different type of critical flow, and they influence each other, thereby influencing the final passage of secondary electrons detected by the scintillator and thus affecting the resulting displayed image.
format Online
Article
Text
id pubmed-10223060
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102230602023-05-28 Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers Maxa, Jiří Neděla, Vilém Šabacká, Pavla Binar, Tomáš Sensors (Basel) Article The article describes the combination of experimental measurements with mathematical–physics analyses in flow investigation in the chambers of the scintillator detector, which is a part of the environmental scanning electron microscope. The chambers are divided with apertures by small openings that keep the desirable pressure differences between three chambers: The specimen chamber, the differentially pumped intermediate chamber, and the scintillator chamber. There are conflicting demands on these apertures. On the one hand, the diameter of the apertures must be as big as possible so that they incur minimal losses of the passing secondary electrons. On the other hand, it is possible to magnify the apertures only to a certain extent so the rotary and turbomolecular vacuum pump can maintain the required operating pressures in separate chambers. The article describes the combination of experimental measurement using an absolute pressure sensor and mathematical physics analysis to map all the specifics of the emerging critical supersonic flow in apertures between the chambers. Based on the experiments and their tuned analyses, the most effective variant of combining the sizes of each aperture concerning different operating pressures in the detector is determined. The situation is made more difficult by the described fact that each aperture separates a different pressure gradient, so the gas flow through each aperture has its own characteristics with a different type of critical flow, and they influence each other, thereby influencing the final passage of secondary electrons detected by the scintillator and thus affecting the resulting displayed image. MDPI 2023-05-18 /pmc/articles/PMC10223060/ /pubmed/37430777 http://dx.doi.org/10.3390/s23104861 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Maxa, Jiří
Neděla, Vilém
Šabacká, Pavla
Binar, Tomáš
Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers
title Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers
title_full Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers
title_fullStr Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers
title_full_unstemmed Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers
title_short Impact of Supersonic Flow in Scintillator Detector Apertures on the Resulting Pumping Effect of the Vacuum Chambers
title_sort impact of supersonic flow in scintillator detector apertures on the resulting pumping effect of the vacuum chambers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223060/
https://www.ncbi.nlm.nih.gov/pubmed/37430777
http://dx.doi.org/10.3390/s23104861
work_keys_str_mv AT maxajiri impactofsupersonicflowinscintillatordetectoraperturesontheresultingpumpingeffectofthevacuumchambers
AT nedelavilem impactofsupersonicflowinscintillatordetectoraperturesontheresultingpumpingeffectofthevacuumchambers
AT sabackapavla impactofsupersonicflowinscintillatordetectoraperturesontheresultingpumpingeffectofthevacuumchambers
AT binartomas impactofsupersonicflowinscintillatordetectoraperturesontheresultingpumpingeffectofthevacuumchambers