Cargando…

A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow

Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas–liquid two-phase flow in small channels. To ach...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheng, Bixia, Huang, Junchao, Ji, Haifeng, Huang, Zhiyao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223952/
https://www.ncbi.nlm.nih.gov/pubmed/37430800
http://dx.doi.org/10.3390/s23104886
_version_ 1785050061864960000
author Sheng, Bixia
Huang, Junchao
Ji, Haifeng
Huang, Zhiyao
author_facet Sheng, Bixia
Huang, Junchao
Ji, Haifeng
Huang, Zhiyao
author_sort Sheng, Bixia
collection PubMed
description Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas–liquid two-phase flow in small channels. To achieve a compact design and to reduce the influence of the slug/bubble deformation and the relative position change on the velocity measurement, an electrode of the upstream sensor is reused as an electrode of the downstream sensor. Meanwhile, a switching unit is introduced to ensure the independence and consistency of the upstream sensor and the downstream sensor. To further improve the synchronization of the upstream sensor and the downstream sensor, fast switching and time compensation are also introduced. Finally, with the obtained upstream and downstream conductance signals, the velocity measurement is achieved by the principle of cross-correlation velocity measurement. To test the measurement performance of the developed system, experiments are carried out on a prototype with a small channel of 2.5 mm. The experimental results show that the compact design (three-electrode construction) is successful, and its measurement performance is satisfactory. The velocity range for the bubble flow is 0.312–0.816 m/s, and the maximum relative error of the flow rate measurement is 4.54%. The velocity range for the slug flow is 0.161 m/s–1.250 m/s, and the maximum relative error of the flow rate measurement is 3.70%.
format Online
Article
Text
id pubmed-10223952
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-102239522023-05-28 A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow Sheng, Bixia Huang, Junchao Ji, Haifeng Huang, Zhiyao Sensors (Basel) Article Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas–liquid two-phase flow in small channels. To achieve a compact design and to reduce the influence of the slug/bubble deformation and the relative position change on the velocity measurement, an electrode of the upstream sensor is reused as an electrode of the downstream sensor. Meanwhile, a switching unit is introduced to ensure the independence and consistency of the upstream sensor and the downstream sensor. To further improve the synchronization of the upstream sensor and the downstream sensor, fast switching and time compensation are also introduced. Finally, with the obtained upstream and downstream conductance signals, the velocity measurement is achieved by the principle of cross-correlation velocity measurement. To test the measurement performance of the developed system, experiments are carried out on a prototype with a small channel of 2.5 mm. The experimental results show that the compact design (three-electrode construction) is successful, and its measurement performance is satisfactory. The velocity range for the bubble flow is 0.312–0.816 m/s, and the maximum relative error of the flow rate measurement is 4.54%. The velocity range for the slug flow is 0.161 m/s–1.250 m/s, and the maximum relative error of the flow rate measurement is 3.70%. MDPI 2023-05-19 /pmc/articles/PMC10223952/ /pubmed/37430800 http://dx.doi.org/10.3390/s23104886 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sheng, Bixia
Huang, Junchao
Ji, Haifeng
Huang, Zhiyao
A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
title A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
title_full A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
title_fullStr A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
title_full_unstemmed A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
title_short A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
title_sort new contactless cross-correlation velocity measurement system for gas–liquid two-phase flow
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223952/
https://www.ncbi.nlm.nih.gov/pubmed/37430800
http://dx.doi.org/10.3390/s23104886
work_keys_str_mv AT shengbixia anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT huangjunchao anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT jihaifeng anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT huangzhiyao anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT shengbixia newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT huangjunchao newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT jihaifeng newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow
AT huangzhiyao newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow