Cargando…
A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow
Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas–liquid two-phase flow in small channels. To ach...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223952/ https://www.ncbi.nlm.nih.gov/pubmed/37430800 http://dx.doi.org/10.3390/s23104886 |
_version_ | 1785050061864960000 |
---|---|
author | Sheng, Bixia Huang, Junchao Ji, Haifeng Huang, Zhiyao |
author_facet | Sheng, Bixia Huang, Junchao Ji, Haifeng Huang, Zhiyao |
author_sort | Sheng, Bixia |
collection | PubMed |
description | Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas–liquid two-phase flow in small channels. To achieve a compact design and to reduce the influence of the slug/bubble deformation and the relative position change on the velocity measurement, an electrode of the upstream sensor is reused as an electrode of the downstream sensor. Meanwhile, a switching unit is introduced to ensure the independence and consistency of the upstream sensor and the downstream sensor. To further improve the synchronization of the upstream sensor and the downstream sensor, fast switching and time compensation are also introduced. Finally, with the obtained upstream and downstream conductance signals, the velocity measurement is achieved by the principle of cross-correlation velocity measurement. To test the measurement performance of the developed system, experiments are carried out on a prototype with a small channel of 2.5 mm. The experimental results show that the compact design (three-electrode construction) is successful, and its measurement performance is satisfactory. The velocity range for the bubble flow is 0.312–0.816 m/s, and the maximum relative error of the flow rate measurement is 4.54%. The velocity range for the slug flow is 0.161 m/s–1.250 m/s, and the maximum relative error of the flow rate measurement is 3.70%. |
format | Online Article Text |
id | pubmed-10223952 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-102239522023-05-28 A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow Sheng, Bixia Huang, Junchao Ji, Haifeng Huang, Zhiyao Sensors (Basel) Article Based on the principle of Contactless Conductivity Detection (CCD), a new contactless cross-correlation velocity measurement system with a three-electrode construction is developed in this work and applied to the contactless velocity measurement of gas–liquid two-phase flow in small channels. To achieve a compact design and to reduce the influence of the slug/bubble deformation and the relative position change on the velocity measurement, an electrode of the upstream sensor is reused as an electrode of the downstream sensor. Meanwhile, a switching unit is introduced to ensure the independence and consistency of the upstream sensor and the downstream sensor. To further improve the synchronization of the upstream sensor and the downstream sensor, fast switching and time compensation are also introduced. Finally, with the obtained upstream and downstream conductance signals, the velocity measurement is achieved by the principle of cross-correlation velocity measurement. To test the measurement performance of the developed system, experiments are carried out on a prototype with a small channel of 2.5 mm. The experimental results show that the compact design (three-electrode construction) is successful, and its measurement performance is satisfactory. The velocity range for the bubble flow is 0.312–0.816 m/s, and the maximum relative error of the flow rate measurement is 4.54%. The velocity range for the slug flow is 0.161 m/s–1.250 m/s, and the maximum relative error of the flow rate measurement is 3.70%. MDPI 2023-05-19 /pmc/articles/PMC10223952/ /pubmed/37430800 http://dx.doi.org/10.3390/s23104886 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sheng, Bixia Huang, Junchao Ji, Haifeng Huang, Zhiyao A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow |
title | A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow |
title_full | A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow |
title_fullStr | A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow |
title_full_unstemmed | A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow |
title_short | A New Contactless Cross-Correlation Velocity Measurement System for Gas–Liquid Two-Phase Flow |
title_sort | new contactless cross-correlation velocity measurement system for gas–liquid two-phase flow |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10223952/ https://www.ncbi.nlm.nih.gov/pubmed/37430800 http://dx.doi.org/10.3390/s23104886 |
work_keys_str_mv | AT shengbixia anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT huangjunchao anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT jihaifeng anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT huangzhiyao anewcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT shengbixia newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT huangjunchao newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT jihaifeng newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow AT huangzhiyao newcontactlesscrosscorrelationvelocitymeasurementsystemforgasliquidtwophaseflow |