Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg

Transcatheter closure of Perimembranous VSDs (PMVSD) remains challenging particularly in infants. The aim of this study is to evaluate the efficacy and safety of transfemoral PMVSD device closure in infants weighing ≤ 10 kg in a single centre. Retrospective review of departmental databases and medic...

Descripción completa

Detalles Bibliográficos
Autores principales: Alshahrani, Dhafer, Linnane, Niall, McCrossan, Brian, Oslizlok, Paul, McMahon, Colin J., Walsh, Kevin P., Kenny, Damien P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224829/
https://www.ncbi.nlm.nih.gov/pubmed/36698044
http://dx.doi.org/10.1007/s00246-023-03100-5
_version_ 1785050280653488128
author Alshahrani, Dhafer
Linnane, Niall
McCrossan, Brian
Oslizlok, Paul
McMahon, Colin J.
Walsh, Kevin P.
Kenny, Damien P.
author_facet Alshahrani, Dhafer
Linnane, Niall
McCrossan, Brian
Oslizlok, Paul
McMahon, Colin J.
Walsh, Kevin P.
Kenny, Damien P.
author_sort Alshahrani, Dhafer
collection PubMed
description Transcatheter closure of Perimembranous VSDs (PMVSD) remains challenging particularly in infants. The aim of this study is to evaluate the efficacy and safety of transfemoral PMVSD device closure in infants weighing ≤ 10 kg in a single centre. Retrospective review of departmental databases and medical charts to define patient cohort and collect demographic, procedural and follow-up data. Between July 2014 and March 2021, 16 patients underwent attempted transfemoral PMVSD device closure (12 retrograde) at a median age of 11 months (interquartile range [IQR] 9–15.5) and a median weight of 8.3 kg (IQR 7.2–9.5). All patients were either symptomatic, had progressive left heart dilation or had VSD associated valve regurgitation. Median defect size on pre-procedural transoesophageal echocardiography was 6.8 mm (IQR 6–8.5). Median device waist size was 6 mm (IQR 4.5–8). Successful device placement was achieved in 14 patients (88%). One patient developed moderate aortic and tricuspid valve regurgitation upon retrograde and antegrade device deployment, respectively, and subsequently underwent surgical closure. The second patient developed progressive aortic regurgitation (AR) 2 days post procedure, and also underwent surgical removal with no residual AR. There was no cases of device embolization and no femoral arterial compromise. On median follow-up of 40.5 months (IQR 25–64), none of the patients developed complete heart block. Three patients (18.75%) had small residual shunts at latest follow-up which have not required any further intervention. Device closure of PMVSD’s in children weighing ≤ 10 kg is feasible and safe with good procedural success rates. Use of both the antegrade and retrograde approaches may be necessary depending on anatomical variances.
format Online
Article
Text
id pubmed-10224829
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-102248292023-05-29 Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg Alshahrani, Dhafer Linnane, Niall McCrossan, Brian Oslizlok, Paul McMahon, Colin J. Walsh, Kevin P. Kenny, Damien P. Pediatr Cardiol Research Transcatheter closure of Perimembranous VSDs (PMVSD) remains challenging particularly in infants. The aim of this study is to evaluate the efficacy and safety of transfemoral PMVSD device closure in infants weighing ≤ 10 kg in a single centre. Retrospective review of departmental databases and medical charts to define patient cohort and collect demographic, procedural and follow-up data. Between July 2014 and March 2021, 16 patients underwent attempted transfemoral PMVSD device closure (12 retrograde) at a median age of 11 months (interquartile range [IQR] 9–15.5) and a median weight of 8.3 kg (IQR 7.2–9.5). All patients were either symptomatic, had progressive left heart dilation or had VSD associated valve regurgitation. Median defect size on pre-procedural transoesophageal echocardiography was 6.8 mm (IQR 6–8.5). Median device waist size was 6 mm (IQR 4.5–8). Successful device placement was achieved in 14 patients (88%). One patient developed moderate aortic and tricuspid valve regurgitation upon retrograde and antegrade device deployment, respectively, and subsequently underwent surgical closure. The second patient developed progressive aortic regurgitation (AR) 2 days post procedure, and also underwent surgical removal with no residual AR. There was no cases of device embolization and no femoral arterial compromise. On median follow-up of 40.5 months (IQR 25–64), none of the patients developed complete heart block. Three patients (18.75%) had small residual shunts at latest follow-up which have not required any further intervention. Device closure of PMVSD’s in children weighing ≤ 10 kg is feasible and safe with good procedural success rates. Use of both the antegrade and retrograde approaches may be necessary depending on anatomical variances. Springer US 2023-01-25 2023 /pmc/articles/PMC10224829/ /pubmed/36698044 http://dx.doi.org/10.1007/s00246-023-03100-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Alshahrani, Dhafer
Linnane, Niall
McCrossan, Brian
Oslizlok, Paul
McMahon, Colin J.
Walsh, Kevin P.
Kenny, Damien P.
Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
title Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
title_full Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
title_fullStr Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
title_full_unstemmed Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
title_short Transfemoral Perimembranous Ventricular Septal Defect Device Closure in Infants Weighing ≤ 10 kg
title_sort transfemoral perimembranous ventricular septal defect device closure in infants weighing ≤ 10 kg
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224829/
https://www.ncbi.nlm.nih.gov/pubmed/36698044
http://dx.doi.org/10.1007/s00246-023-03100-5
work_keys_str_mv AT alshahranidhafer transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg
AT linnaneniall transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg
AT mccrossanbrian transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg
AT oslizlokpaul transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg
AT mcmahoncolinj transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg
AT walshkevinp transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg
AT kennydamienp transfemoralperimembranousventricularseptaldefectdeviceclosureininfantsweighing10kg