Cargando…
Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuff...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224938/ https://www.ncbi.nlm.nih.gov/pubmed/37244974 http://dx.doi.org/10.1038/s41598-023-35492-y |
_version_ | 1785050298646003712 |
---|---|
author | Joung, Jingon Jung, Chul-Woo Lee, Hyung-Chul Chae, Moon-Jung Kim, Hae-Sung Park, Jonghun Shin, Won-Yong Kim, Changhyun Lee, Minhyung Choi, Changwoo |
author_facet | Joung, Jingon Jung, Chul-Woo Lee, Hyung-Chul Chae, Moon-Jung Kim, Hae-Sung Park, Jonghun Shin, Won-Yong Kim, Changhyun Lee, Minhyung Choi, Changwoo |
author_sort | Joung, Jingon |
collection | PubMed |
description | Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text] , [Formula: see text] , and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel ‘standard deviation of subject-calibration centring (SDS)’ metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services. |
format | Online Article Text |
id | pubmed-10224938 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-102249382023-05-29 Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations Joung, Jingon Jung, Chul-Woo Lee, Hyung-Chul Chae, Moon-Jung Kim, Hae-Sung Park, Jonghun Shin, Won-Yong Kim, Changhyun Lee, Minhyung Choi, Changwoo Sci Rep Article Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text] , [Formula: see text] , and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel ‘standard deviation of subject-calibration centring (SDS)’ metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services. Nature Publishing Group UK 2023-05-27 /pmc/articles/PMC10224938/ /pubmed/37244974 http://dx.doi.org/10.1038/s41598-023-35492-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Joung, Jingon Jung, Chul-Woo Lee, Hyung-Chul Chae, Moon-Jung Kim, Hae-Sung Park, Jonghun Shin, Won-Yong Kim, Changhyun Lee, Minhyung Choi, Changwoo Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations |
title | Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations |
title_full | Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations |
title_fullStr | Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations |
title_full_unstemmed | Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations |
title_short | Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations |
title_sort | continuous cuffless blood pressure monitoring using photoplethysmography-based ppg2bp-net for high intrasubject blood pressure variations |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224938/ https://www.ncbi.nlm.nih.gov/pubmed/37244974 http://dx.doi.org/10.1038/s41598-023-35492-y |
work_keys_str_mv | AT joungjingon continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT jungchulwoo continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT leehyungchul continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT chaemoonjung continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT kimhaesung continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT parkjonghun continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT shinwonyong continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT kimchanghyun continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT leeminhyung continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations AT choichangwoo continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations |