Cargando…

Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations

Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuff...

Descripción completa

Detalles Bibliográficos
Autores principales: Joung, Jingon, Jung, Chul-Woo, Lee, Hyung-Chul, Chae, Moon-Jung, Kim, Hae-Sung, Park, Jonghun, Shin, Won-Yong, Kim, Changhyun, Lee, Minhyung, Choi, Changwoo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224938/
https://www.ncbi.nlm.nih.gov/pubmed/37244974
http://dx.doi.org/10.1038/s41598-023-35492-y
_version_ 1785050298646003712
author Joung, Jingon
Jung, Chul-Woo
Lee, Hyung-Chul
Chae, Moon-Jung
Kim, Hae-Sung
Park, Jonghun
Shin, Won-Yong
Kim, Changhyun
Lee, Minhyung
Choi, Changwoo
author_facet Joung, Jingon
Jung, Chul-Woo
Lee, Hyung-Chul
Chae, Moon-Jung
Kim, Hae-Sung
Park, Jonghun
Shin, Won-Yong
Kim, Changhyun
Lee, Minhyung
Choi, Changwoo
author_sort Joung, Jingon
collection PubMed
description Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text] , [Formula: see text] , and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel ‘standard deviation of subject-calibration centring (SDS)’ metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services.
format Online
Article
Text
id pubmed-10224938
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-102249382023-05-29 Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations Joung, Jingon Jung, Chul-Woo Lee, Hyung-Chul Chae, Moon-Jung Kim, Hae-Sung Park, Jonghun Shin, Won-Yong Kim, Changhyun Lee, Minhyung Choi, Changwoo Sci Rep Article Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP measurement of existing cuff-based BP technologies, though they may achieve reliable accuracy, cuffless BP measurement technologies, such as pulse transit/arrival time, pulse wave analysis, and image processing, have been studied to obtain C3 BP measurement. One of the recent cuffless BP measurement technologies, innovative machine-learning and artificial intelligence-based technologies that can estimate BP by extracting BP-related features from photoplethysmography (PPG)-based waveforms have attracted interdisciplinary attention of the medical and computer scientists owing to their handiness and effectiveness for both C3 and accurate, i.e., C3A, BP measurement. However, C3A BP measurement remains still unattainable because the accuracy of the existing PPG-based BP methods was not sufficiently justified for subject-independent and highly varying BP, which is a typical case in practice. To circumvent this issue, a novel convolutional neural network(CNN)- and calibration-based model (PPG2BP-Net) was designed by using a comparative paired one-dimensional CNN structure to estimate highly varying intrasubject BP. To this end, approximately [Formula: see text] , [Formula: see text] , and [Formula: see text] of 4185 cleaned, independent subjects from 25,779 surgical cases were used for training, validating, and testing the proposed PPG2BP-Net, respectively and exclusively (i.e., subject-independent modelling). For quantifying the intrasubject BP variation from an initial calibration BP, a novel ‘standard deviation of subject-calibration centring (SDS)’ metric is proposed wherein high SDS represents high intrasubject BP variation from the calibration BP and vice versa. PPG2BP-Net achieved accurately estimated systolic and diastolic BP values despite high intrasubject variability. In 629-subject data acquired after 20 minutes following the A-line (arterial line) insertion, low error mean and standard deviation of [Formula: see text] and [Formula: see text] for highly varying A-line systolic and diastolic BP values, respectively, where their SDSs are 15.375 and 8.745. This study moves one step forward in developing the C3A cuffless BP estimation devices that enable the push and agile pull services. Nature Publishing Group UK 2023-05-27 /pmc/articles/PMC10224938/ /pubmed/37244974 http://dx.doi.org/10.1038/s41598-023-35492-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Joung, Jingon
Jung, Chul-Woo
Lee, Hyung-Chul
Chae, Moon-Jung
Kim, Hae-Sung
Park, Jonghun
Shin, Won-Yong
Kim, Changhyun
Lee, Minhyung
Choi, Changwoo
Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
title Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
title_full Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
title_fullStr Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
title_full_unstemmed Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
title_short Continuous cuffless blood pressure monitoring using photoplethysmography-based PPG2BP-net for high intrasubject blood pressure variations
title_sort continuous cuffless blood pressure monitoring using photoplethysmography-based ppg2bp-net for high intrasubject blood pressure variations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10224938/
https://www.ncbi.nlm.nih.gov/pubmed/37244974
http://dx.doi.org/10.1038/s41598-023-35492-y
work_keys_str_mv AT joungjingon continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT jungchulwoo continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT leehyungchul continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT chaemoonjung continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT kimhaesung continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT parkjonghun continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT shinwonyong continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT kimchanghyun continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT leeminhyung continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations
AT choichangwoo continuouscufflessbloodpressuremonitoringusingphotoplethysmographybasedppg2bpnetforhighintrasubjectbloodpressurevariations