Cargando…

Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells

[Image: see text] In nanomechanical mass spectrometry, sensing devices are commonly placed in the vacuum environment and a stream of analytes is directed toward the sensor surface for measurement. Beam structures, such as double-clamped nanobeams and nanocantilevers, are commonly used due to their l...

Descripción completa

Detalles Bibliográficos
Autores principales: Sanz-Jiménez, Adrián, Ruz, Jose J., Gil-Santos, Eduardo, Malvar, Oscar, García-López, Sergio, Kosaka, Priscila M., Cano, Álvaro, Calleja, Montserrat, Tamayo, Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10226162/
https://www.ncbi.nlm.nih.gov/pubmed/37122237
http://dx.doi.org/10.1021/acssensors.3c00338
_version_ 1785050519699456000
author Sanz-Jiménez, Adrián
Ruz, Jose J.
Gil-Santos, Eduardo
Malvar, Oscar
García-López, Sergio
Kosaka, Priscila M.
Cano, Álvaro
Calleja, Montserrat
Tamayo, Javier
author_facet Sanz-Jiménez, Adrián
Ruz, Jose J.
Gil-Santos, Eduardo
Malvar, Oscar
García-López, Sergio
Kosaka, Priscila M.
Cano, Álvaro
Calleja, Montserrat
Tamayo, Javier
author_sort Sanz-Jiménez, Adrián
collection PubMed
description [Image: see text] In nanomechanical mass spectrometry, sensing devices are commonly placed in the vacuum environment and a stream of analytes is directed toward the sensor surface for measurement. Beam structures, such as double-clamped nanobeams and nanocantilevers, are commonly used due to their low inertial mass and the simplicity of the analytical models for mass extraction. The drawback of such structures is their low capture areas, compromising the capture efficiency and throughput of this technique. Bi-axisymmetric resonators, such as ultrathin square or circular membranes, arise as an optimal geometry to maximize capture efficiency while minimizing the device inertial mass. However, these structures present degenerate mechanical modes, whose frequency perturbations upon analyte adsorption are not well described by commonly used models. Furthermore, prior knowledge of the vibration mode shapes of the sensor is crucial for the correct calculation of the analyte’s mass, and the mode shape of degenerate modes may change significantly after every adsorption event. In this work, we present an accurate analytical theory to describe the effect of mass adsorption on the degenerate modes of square membrane resonators and propose two different methods based on the new theory to update the vibration mode shapes after every adsorption event. Finally, we illustrate the problem experimentally obtaining the mass and adsorption position of individual Escherichia coli K-12 bacterial cells on commercial square silicon nitride membranes fabricated with very small tolerances.
format Online
Article
Text
id pubmed-10226162
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-102261622023-05-30 Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells Sanz-Jiménez, Adrián Ruz, Jose J. Gil-Santos, Eduardo Malvar, Oscar García-López, Sergio Kosaka, Priscila M. Cano, Álvaro Calleja, Montserrat Tamayo, Javier ACS Sens [Image: see text] In nanomechanical mass spectrometry, sensing devices are commonly placed in the vacuum environment and a stream of analytes is directed toward the sensor surface for measurement. Beam structures, such as double-clamped nanobeams and nanocantilevers, are commonly used due to their low inertial mass and the simplicity of the analytical models for mass extraction. The drawback of such structures is their low capture areas, compromising the capture efficiency and throughput of this technique. Bi-axisymmetric resonators, such as ultrathin square or circular membranes, arise as an optimal geometry to maximize capture efficiency while minimizing the device inertial mass. However, these structures present degenerate mechanical modes, whose frequency perturbations upon analyte adsorption are not well described by commonly used models. Furthermore, prior knowledge of the vibration mode shapes of the sensor is crucial for the correct calculation of the analyte’s mass, and the mode shape of degenerate modes may change significantly after every adsorption event. In this work, we present an accurate analytical theory to describe the effect of mass adsorption on the degenerate modes of square membrane resonators and propose two different methods based on the new theory to update the vibration mode shapes after every adsorption event. Finally, we illustrate the problem experimentally obtaining the mass and adsorption position of individual Escherichia coli K-12 bacterial cells on commercial square silicon nitride membranes fabricated with very small tolerances. American Chemical Society 2023-05-01 /pmc/articles/PMC10226162/ /pubmed/37122237 http://dx.doi.org/10.1021/acssensors.3c00338 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Sanz-Jiménez, Adrián
Ruz, Jose J.
Gil-Santos, Eduardo
Malvar, Oscar
García-López, Sergio
Kosaka, Priscila M.
Cano, Álvaro
Calleja, Montserrat
Tamayo, Javier
Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells
title Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells
title_full Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells
title_fullStr Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells
title_full_unstemmed Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells
title_short Square Membrane Resonators Supporting Degenerate Modes of Vibration for High-Throughput Mass Spectrometry of Single Bacterial Cells
title_sort square membrane resonators supporting degenerate modes of vibration for high-throughput mass spectrometry of single bacterial cells
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10226162/
https://www.ncbi.nlm.nih.gov/pubmed/37122237
http://dx.doi.org/10.1021/acssensors.3c00338
work_keys_str_mv AT sanzjimenezadrian squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT ruzjosej squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT gilsantoseduardo squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT malvaroscar squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT garcialopezsergio squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT kosakapriscilam squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT canoalvaro squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT callejamontserrat squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells
AT tamayojavier squaremembraneresonatorssupportingdegeneratemodesofvibrationforhighthroughputmassspectrometryofsinglebacterialcells