Cargando…

Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy

OBJECTIVES: Orthopedic implants have improved the quality of life in aging society but also induces several kinds of tissue reactions, referred to as orthopedic implant hypersensitivity (OIH). The aim of our study is to report the clinical characteristics of OIH and the effects of photobiomodulation...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Ro-Wei, Chang, Chung-Hsing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10227683/
https://www.ncbi.nlm.nih.gov/pubmed/37261304
http://dx.doi.org/10.4103/tcmj.tcmj_255_22
_version_ 1785050826270572544
author Wu, Ro-Wei
Chang, Chung-Hsing
author_facet Wu, Ro-Wei
Chang, Chung-Hsing
author_sort Wu, Ro-Wei
collection PubMed
description OBJECTIVES: Orthopedic implants have improved the quality of life in aging society but also induces several kinds of tissue reactions, referred to as orthopedic implant hypersensitivity (OIH). The aim of our study is to report the clinical characteristics of OIH and the effects of photobiomodulation therapy (PBMT) on these groups of patients. MATERIALS AND METHODS: We collected cases that complained of skin rashes with pruritus after orthopedic implants from January 2017 to June 2022 at the Dermatology clinic in Hualien Tzu Chi Hospital. We recorded the sites and material of orthopedic implants, skin lesions onset time, symptoms, location after implantation, and the disease duration. Laboratory tests were measured, including complete blood count, differential count, serum immunoglobulin E (IgE) level, as well as inflammatory and autoimmune markers. PBMT, including UVB311 nm or low-level laser therapy 808 nm, was performed. Dose, duration, and response were documented. RESULTS: Fourteen patients were diagnosed with OIH; twelve presented with localized eczema at the implant sites, and two with generalized eczema. Eleven patients (78.6%) had either elevated eosinophils percentage (>6%) or IgE level (>200 U/mL) or both. Seven patients (50%) had favorable outcome after PBMT and successfully withdrew from systemic steroid. CONCLUSION: In our case series, localized eczema at implant sites was a common cutaneous presentation in OIH. Hence, a surgical scar at the eczema site or long-term waxing and waning generalized eczema should prompt physicians on the possibility of OIH. Blood eosinophils percentage and serum IgE level can be reference biomarkers for OIH. PBMT provides a noninvasive and effective treatment strategy for immune regulation and tissue regeneration.
format Online
Article
Text
id pubmed-10227683
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-102276832023-05-31 Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy Wu, Ro-Wei Chang, Chung-Hsing Tzu Chi Med J Original Article OBJECTIVES: Orthopedic implants have improved the quality of life in aging society but also induces several kinds of tissue reactions, referred to as orthopedic implant hypersensitivity (OIH). The aim of our study is to report the clinical characteristics of OIH and the effects of photobiomodulation therapy (PBMT) on these groups of patients. MATERIALS AND METHODS: We collected cases that complained of skin rashes with pruritus after orthopedic implants from January 2017 to June 2022 at the Dermatology clinic in Hualien Tzu Chi Hospital. We recorded the sites and material of orthopedic implants, skin lesions onset time, symptoms, location after implantation, and the disease duration. Laboratory tests were measured, including complete blood count, differential count, serum immunoglobulin E (IgE) level, as well as inflammatory and autoimmune markers. PBMT, including UVB311 nm or low-level laser therapy 808 nm, was performed. Dose, duration, and response were documented. RESULTS: Fourteen patients were diagnosed with OIH; twelve presented with localized eczema at the implant sites, and two with generalized eczema. Eleven patients (78.6%) had either elevated eosinophils percentage (>6%) or IgE level (>200 U/mL) or both. Seven patients (50%) had favorable outcome after PBMT and successfully withdrew from systemic steroid. CONCLUSION: In our case series, localized eczema at implant sites was a common cutaneous presentation in OIH. Hence, a surgical scar at the eczema site or long-term waxing and waning generalized eczema should prompt physicians on the possibility of OIH. Blood eosinophils percentage and serum IgE level can be reference biomarkers for OIH. PBMT provides a noninvasive and effective treatment strategy for immune regulation and tissue regeneration. Wolters Kluwer - Medknow 2023-02-21 /pmc/articles/PMC10227683/ /pubmed/37261304 http://dx.doi.org/10.4103/tcmj.tcmj_255_22 Text en Copyright: © 2023 Tzu Chi Medical Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Wu, Ro-Wei
Chang, Chung-Hsing
Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_full Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_fullStr Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_full_unstemmed Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_short Orthopedic implant hypersensitivity: Characterization of clinical presentation and effects of photobiomodulation therapy
title_sort orthopedic implant hypersensitivity: characterization of clinical presentation and effects of photobiomodulation therapy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10227683/
https://www.ncbi.nlm.nih.gov/pubmed/37261304
http://dx.doi.org/10.4103/tcmj.tcmj_255_22
work_keys_str_mv AT wurowei orthopedicimplanthypersensitivitycharacterizationofclinicalpresentationandeffectsofphotobiomodulationtherapy
AT changchunghsing orthopedicimplanthypersensitivitycharacterizationofclinicalpresentationandeffectsofphotobiomodulationtherapy