Clinical outcomes of Najuta thoracic stent graft system for arch aneurysms

OBJECTIVES: We aimed to elucidate the perioperative and short-term clinical outcomes of the Najuta thoracic stent graft system with fenestrations for supra-aortic vessels. METHODS: We retrospectively investigated the perioperative and short-term clinical outcomes of 20 patients treated for arch or d...

Descripción completa

Detalles Bibliográficos
Autores principales: Iida, Yasunori, Hachiya, Takashi, Oka, Hidetoshi, Inaba, Yu, Miki, Takahisa, Shimizu, Hideyuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10228724/
https://www.ncbi.nlm.nih.gov/pubmed/37260597
http://dx.doi.org/10.3389/fsurg.2023.1167714
Descripción
Sumario:OBJECTIVES: We aimed to elucidate the perioperative and short-term clinical outcomes of the Najuta thoracic stent graft system with fenestrations for supra-aortic vessels. METHODS: We retrospectively investigated the perioperative and short-term clinical outcomes of 20 patients treated for arch or distal arch aneurysms using the Najuta thoracic stent graft system during the period from May 2019 to February 2023. RESULTS: The technical success rate of the Najuta thoracic stent graft system was 95%. Of the 20 patients, 17 patients (85.0%) underwent concomitant extra-anatomical supra-aortic bypass. Postoperative CT revealed type Ia (n = 2) and type II (n = 3) endoleaks which disappeared on follow-up. The postoperative complications were stroke (n = 2, 10.0%), paraplegia (n = 1, 5.0%), and paraparesis (n = 1, 5.0%). In a very old patient, a blood transfusion was performed from the common iliac artery using the retroperitoneal approach. There were no aorta-related complications such as retrograde type A dissection or distal stent graft–induced new entry. CONCLUSIONS: We treated arch or distal arch thoracic aneurysms by inserting a tube-type stent graft as a scaffold on the peripheral site and placing the Najuta thoracic stent graft on the proximal site. By extending the landing zone to Zone 0 and using a low radial force, which is a feature of the Najuta thoracic stent graft system, postoperative bird-beak and aorta-related complications were avoided. The treatment of arch and distal arch aortic aneurysms using the Najuta thoracic stent graft system showed acceptable perioperative and short-term clinical outcomes. Thoracic endovascular aortic repair using the Najuta thoracic stent graft system may be a potential treatment option for arch and distal arch aortic aneurysms, warranting further studies.