Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom

OBJECTIVE: Sonosensitive high-boiling point perfluorocarbon F(8)TAC(18)-PFOB emulsions previously exhibited thermal enhancement during focused ultrasound heating in ex vivo pig livers, kidneys and a laminar flow phantom. The main objectives of this study were to evaluate heating under turbulent cond...

Descripción completa

Detalles Bibliográficos
Autores principales: Holman, Ryan, Guillemin, Pauline C., Lorton, Orane, Desgranges, Stéphane, Contino-Pépin, Christiane, Salomir, Rares
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Pergamon Press 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10229106/
https://www.ncbi.nlm.nih.gov/pubmed/37117139
http://dx.doi.org/10.1016/j.ultrasmedbio.2023.01.022
_version_ 1785051168954646528
author Holman, Ryan
Guillemin, Pauline C.
Lorton, Orane
Desgranges, Stéphane
Contino-Pépin, Christiane
Salomir, Rares
author_facet Holman, Ryan
Guillemin, Pauline C.
Lorton, Orane
Desgranges, Stéphane
Contino-Pépin, Christiane
Salomir, Rares
author_sort Holman, Ryan
collection PubMed
description OBJECTIVE: Sonosensitive high-boiling point perfluorocarbon F(8)TAC(18)-PFOB emulsions previously exhibited thermal enhancement during focused ultrasound heating in ex vivo pig livers, kidneys and a laminar flow phantom. The main objectives of this study were to evaluate heating under turbulent conditions, observe perfusion effects, quantify heating in terms of acoustic absorption and model the experimental data. METHODS: In this study, similar perfluorocarbon emulsions were circulated at incremental concentrations of 0.07, 0.13, 0.19 and 0.25% v:v through a percolated turbulent flow phantom, more representative of the biological tissue than a laminar flow phantom. The concentrations represent the droplet content in only the perfused fluid, rather than the droplet concentration throughout the entire cross-section. The temperature was measured with magnetic resonance thermometry, during focused ultrasound sonications of 67 W, 95% duty cycle and 33 s duration. These were used in Bioheat equation simulations to investigate in silico the thermal phenomena. The temperature change was compared with the control condition by circulating de-gassed and de-ionized water through the flow phantom without droplets. RESULTS: With these 1.24 µm diameter droplets at 0.25% v:v, the acoustic absorption coefficient increased from 0.93 ± 0.05 at 0.0% v:v to 1.82 ± 0.22 m(–1) at 0.25% v:v using a 0.1 mL s(–1) flow rate. Without perfusion at 0.25% v:v, an increase was observed from 1.23 ± 0.07 m(–1) at 0.0% v:v to 1.65 ± 0.17 m(–1). CONCLUSION: The results further support previously reported thermal enhancement with F(8)TAC(18)-PFOB emulsion, quantified the increased absorption at small concentration intervals, illustrated that the effects can be observed in a variety of visceral tissue models and provided a method to simulate untested scenarios.
format Online
Article
Text
id pubmed-10229106
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Pergamon Press
record_format MEDLINE/PubMed
spelling pubmed-102291062023-07-01 Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom Holman, Ryan Guillemin, Pauline C. Lorton, Orane Desgranges, Stéphane Contino-Pépin, Christiane Salomir, Rares Ultrasound Med Biol Original Contribution OBJECTIVE: Sonosensitive high-boiling point perfluorocarbon F(8)TAC(18)-PFOB emulsions previously exhibited thermal enhancement during focused ultrasound heating in ex vivo pig livers, kidneys and a laminar flow phantom. The main objectives of this study were to evaluate heating under turbulent conditions, observe perfusion effects, quantify heating in terms of acoustic absorption and model the experimental data. METHODS: In this study, similar perfluorocarbon emulsions were circulated at incremental concentrations of 0.07, 0.13, 0.19 and 0.25% v:v through a percolated turbulent flow phantom, more representative of the biological tissue than a laminar flow phantom. The concentrations represent the droplet content in only the perfused fluid, rather than the droplet concentration throughout the entire cross-section. The temperature was measured with magnetic resonance thermometry, during focused ultrasound sonications of 67 W, 95% duty cycle and 33 s duration. These were used in Bioheat equation simulations to investigate in silico the thermal phenomena. The temperature change was compared with the control condition by circulating de-gassed and de-ionized water through the flow phantom without droplets. RESULTS: With these 1.24 µm diameter droplets at 0.25% v:v, the acoustic absorption coefficient increased from 0.93 ± 0.05 at 0.0% v:v to 1.82 ± 0.22 m(–1) at 0.25% v:v using a 0.1 mL s(–1) flow rate. Without perfusion at 0.25% v:v, an increase was observed from 1.23 ± 0.07 m(–1) at 0.0% v:v to 1.65 ± 0.17 m(–1). CONCLUSION: The results further support previously reported thermal enhancement with F(8)TAC(18)-PFOB emulsion, quantified the increased absorption at small concentration intervals, illustrated that the effects can be observed in a variety of visceral tissue models and provided a method to simulate untested scenarios. Pergamon Press 2023-07 /pmc/articles/PMC10229106/ /pubmed/37117139 http://dx.doi.org/10.1016/j.ultrasmedbio.2023.01.022 Text en © 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Contribution
Holman, Ryan
Guillemin, Pauline C.
Lorton, Orane
Desgranges, Stéphane
Contino-Pépin, Christiane
Salomir, Rares
Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
title Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
title_full Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
title_fullStr Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
title_full_unstemmed Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
title_short Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance–Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom
title_sort assessing enhanced acoustic absorption from sonosensitive perfluorocarbon emulsion with magnetic resonance–guided high-intensity focused ultrasound and a percolated tissue-mimicking flow phantom
topic Original Contribution
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10229106/
https://www.ncbi.nlm.nih.gov/pubmed/37117139
http://dx.doi.org/10.1016/j.ultrasmedbio.2023.01.022
work_keys_str_mv AT holmanryan assessingenhancedacousticabsorptionfromsonosensitiveperfluorocarbonemulsionwithmagneticresonanceguidedhighintensityfocusedultrasoundandapercolatedtissuemimickingflowphantom
AT guilleminpaulinec assessingenhancedacousticabsorptionfromsonosensitiveperfluorocarbonemulsionwithmagneticresonanceguidedhighintensityfocusedultrasoundandapercolatedtissuemimickingflowphantom
AT lortonorane assessingenhancedacousticabsorptionfromsonosensitiveperfluorocarbonemulsionwithmagneticresonanceguidedhighintensityfocusedultrasoundandapercolatedtissuemimickingflowphantom
AT desgrangesstephane assessingenhancedacousticabsorptionfromsonosensitiveperfluorocarbonemulsionwithmagneticresonanceguidedhighintensityfocusedultrasoundandapercolatedtissuemimickingflowphantom
AT continopepinchristiane assessingenhancedacousticabsorptionfromsonosensitiveperfluorocarbonemulsionwithmagneticresonanceguidedhighintensityfocusedultrasoundandapercolatedtissuemimickingflowphantom
AT salomirrares assessingenhancedacousticabsorptionfromsonosensitiveperfluorocarbonemulsionwithmagneticresonanceguidedhighintensityfocusedultrasoundandapercolatedtissuemimickingflowphantom