Cargando…

Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma

BACKGROUND: Pheochromocytoma (PCC) is rare in cats and plasma (PL) and urinary (U) metanephrines (metanephrine [MN]; normetanephrine [NMN]) measurement is rarely described in cats. OBJECTIVES: We evaluated the utility of PL and U MNs measurement in 10 healthy cats and a cat with a confirmed diagnosi...

Descripción completa

Detalles Bibliográficos
Autores principales: Prego, Maria Teresa, Dias, Maria Joana, Ferreira, Rui Lemos, Gonçalves, Salomé, Dias Domingues, Tiago, Junius, Greet, Van den Steen, Evi, Galac, Sara, Leal, Rodolfo Oliveira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10229322/
https://www.ncbi.nlm.nih.gov/pubmed/37057306
http://dx.doi.org/10.1111/jvim.16648
_version_ 1785051216302047232
author Prego, Maria Teresa
Dias, Maria Joana
Ferreira, Rui Lemos
Gonçalves, Salomé
Dias Domingues, Tiago
Junius, Greet
Van den Steen, Evi
Galac, Sara
Leal, Rodolfo Oliveira
author_facet Prego, Maria Teresa
Dias, Maria Joana
Ferreira, Rui Lemos
Gonçalves, Salomé
Dias Domingues, Tiago
Junius, Greet
Van den Steen, Evi
Galac, Sara
Leal, Rodolfo Oliveira
author_sort Prego, Maria Teresa
collection PubMed
description BACKGROUND: Pheochromocytoma (PCC) is rare in cats and plasma (PL) and urinary (U) metanephrines (metanephrine [MN]; normetanephrine [NMN]) measurement is rarely described in cats. OBJECTIVES: We evaluated the utility of PL and U MNs measurement in 10 healthy cats and a cat with a confirmed diagnosis of pheochromocytoma (PheoCat), using liquid chromatography with tandem mass spectrometry (LC‐MS‐MS). METHODS: Urine and EDTA PL samples collected from each of the 10 cats and the PheoCat were promptly stored at −80°C and remained frozen until analysis. To evaluate U MNs stability, an additional urine sample collected from the healthy cats was refrigerated for 24 hours before freezing. Urinary creatinine concentration (Creat) was assessed using the same spot urine samples to calculate U MNs‐to‐creatinine ratios. RESULTS: The PL‐MN and PL‐NMN median concentrations of the healthy cats were 2.73 and 7.02 nmol/L, respectively. The median U‐MN/Creat and U‐NMN/Creat ratios were 70 and 139 μg/g, respectively. The PheoCat had a PL‐MN of 3.68 nmol/L, PL‐NMN of 66.27 nmol/L, U‐MN/Creat of 179 μg/g, and U‐NMN/Creat of 1262 μg/g. The PheoCat had markedly increased concentrations of both PL and U MNs when compared to the healthy cats. No significant difference was found between U MNs measured in urine samples that underwent 24 hours of refrigeration in comparison to those that were frozen immediately. CONCLUSIONS: We report preliminary reference intervals for PL and U MNs in cats using LC‐MS‐MS and the potential clinical applicability of these biomarkers for the diagnosis of PCC in cats.
format Online
Article
Text
id pubmed-10229322
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley & Sons, Inc.
record_format MEDLINE/PubMed
spelling pubmed-102293222023-06-01 Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma Prego, Maria Teresa Dias, Maria Joana Ferreira, Rui Lemos Gonçalves, Salomé Dias Domingues, Tiago Junius, Greet Van den Steen, Evi Galac, Sara Leal, Rodolfo Oliveira J Vet Intern Med SMALL ANIMAL BACKGROUND: Pheochromocytoma (PCC) is rare in cats and plasma (PL) and urinary (U) metanephrines (metanephrine [MN]; normetanephrine [NMN]) measurement is rarely described in cats. OBJECTIVES: We evaluated the utility of PL and U MNs measurement in 10 healthy cats and a cat with a confirmed diagnosis of pheochromocytoma (PheoCat), using liquid chromatography with tandem mass spectrometry (LC‐MS‐MS). METHODS: Urine and EDTA PL samples collected from each of the 10 cats and the PheoCat were promptly stored at −80°C and remained frozen until analysis. To evaluate U MNs stability, an additional urine sample collected from the healthy cats was refrigerated for 24 hours before freezing. Urinary creatinine concentration (Creat) was assessed using the same spot urine samples to calculate U MNs‐to‐creatinine ratios. RESULTS: The PL‐MN and PL‐NMN median concentrations of the healthy cats were 2.73 and 7.02 nmol/L, respectively. The median U‐MN/Creat and U‐NMN/Creat ratios were 70 and 139 μg/g, respectively. The PheoCat had a PL‐MN of 3.68 nmol/L, PL‐NMN of 66.27 nmol/L, U‐MN/Creat of 179 μg/g, and U‐NMN/Creat of 1262 μg/g. The PheoCat had markedly increased concentrations of both PL and U MNs when compared to the healthy cats. No significant difference was found between U MNs measured in urine samples that underwent 24 hours of refrigeration in comparison to those that were frozen immediately. CONCLUSIONS: We report preliminary reference intervals for PL and U MNs in cats using LC‐MS‐MS and the potential clinical applicability of these biomarkers for the diagnosis of PCC in cats. John Wiley & Sons, Inc. 2023-04-13 /pmc/articles/PMC10229322/ /pubmed/37057306 http://dx.doi.org/10.1111/jvim.16648 Text en © 2023 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals LLC on behalf of American College of Veterinary Internal Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle SMALL ANIMAL
Prego, Maria Teresa
Dias, Maria Joana
Ferreira, Rui Lemos
Gonçalves, Salomé
Dias Domingues, Tiago
Junius, Greet
Van den Steen, Evi
Galac, Sara
Leal, Rodolfo Oliveira
Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
title Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
title_full Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
title_fullStr Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
title_full_unstemmed Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
title_short Plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
title_sort plasma and urinary metanephrine and normetanephrine concentrations using liquid chromatography with tandem mass spectrometry in healthy cats and in a cat with pheochromocytoma
topic SMALL ANIMAL
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10229322/
https://www.ncbi.nlm.nih.gov/pubmed/37057306
http://dx.doi.org/10.1111/jvim.16648
work_keys_str_mv AT pregomariateresa plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT diasmariajoana plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT ferreiraruilemos plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT goncalvessalome plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT diasdominguestiago plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT juniusgreet plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT vandensteenevi plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT galacsara plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma
AT lealrodolfooliveira plasmaandurinarymetanephrineandnormetanephrineconcentrationsusingliquidchromatographywithtandemmassspectrometryinhealthycatsandinacatwithpheochromocytoma