Atraumatic versus cutting needles in fluoroscopic lumbar puncture
OBJECTIVES: Atraumatic needles are known to reduce complication rates of blind lumbar punctures (LP), however, their use in fluoroscopically guided LP is less studied. This study assessed the comparative difficulty of performing fluoroscopic lumbar puncture with atraumatic needles. METHODS: Single-c...
Autores principales: | Lee, Dana Yen Lin, Clements, Warren, Lukies, Matthew |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The British Institute of Radiology.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10230379/ https://www.ncbi.nlm.nih.gov/pubmed/37017612 http://dx.doi.org/10.1259/bjr.20220993 |
Ejemplares similares
-
Atraumatic (pencil-point) versus conventional needles for lumbar
puncture: a clinical practice guideline
por: Rochwerg, Bram, et al.
Publicado: (2018) -
Atraumatic versus traumatic lumbar puncture needles: a systematic review and meta-analysis protocol
por: Nath, Siddharth, et al.
Publicado: (2017) -
Specific lumbar puncture training during clinical clerkship durably increases atraumatic needle use
por: Moisset, Xavier, et al.
Publicado: (2019) -
Retrospective Comparative Analysis of Fluoroscopic-Guided Lumbar Puncture in the Routine Prone Versus Lateral Decubitus Position
por: Bakrukov, Dmitriy, et al.
Publicado: (2021) -
Predictions of the Length of Lumbar Puncture Needles
por: Ma, Hon-Ping, et al.
Publicado: (2014)