How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
[Image: see text] Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width o...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Chemical Society
2023
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233573/ https://www.ncbi.nlm.nih.gov/pubmed/37192335 http://dx.doi.org/10.1021/acs.analchem.3c00471 |
_version_ | 1785052285312696320 |
---|---|
author | Thoben, Christian Raddatz, Christian-Robert Tataroglu, Aykut Kobelt, Tim Zimmermann, Stefan |
author_facet | Thoben, Christian Raddatz, Christian-Robert Tataroglu, Aykut Kobelt, Tim Zimmermann, Stefan |
author_sort | Thoben, Christian |
collection | PubMed |
description | [Image: see text] Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width of the injected ion packet leads to improved resolving power, higher peak amplitudes when operating the IMS at optimum resolving power, and thus a better signal-to-noise ratio despite the reduced number of injected ions. Hereby, the performance of electrospray ionization (ESI)-IMS can be considerably improved. By setting the ion shutter opening time to just 5 μs and slightly increasing the pressure, a high resolving power R(P) > 150 can be achieved with a given drift length of just 75 mm. At such high resolving power, even a mixture of the herbicides isoproturon and chlortoluron having similar ion mobility can be well separated despite short drift length. |
format | Online Article Text |
id | pubmed-10233573 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Chemical Society |
record_format | MEDLINE/PubMed |
spelling | pubmed-102335732023-06-02 How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers Thoben, Christian Raddatz, Christian-Robert Tataroglu, Aykut Kobelt, Tim Zimmermann, Stefan Anal Chem [Image: see text] Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width of the injected ion packet leads to improved resolving power, higher peak amplitudes when operating the IMS at optimum resolving power, and thus a better signal-to-noise ratio despite the reduced number of injected ions. Hereby, the performance of electrospray ionization (ESI)-IMS can be considerably improved. By setting the ion shutter opening time to just 5 μs and slightly increasing the pressure, a high resolving power R(P) > 150 can be achieved with a given drift length of just 75 mm. At such high resolving power, even a mixture of the herbicides isoproturon and chlortoluron having similar ion mobility can be well separated despite short drift length. American Chemical Society 2023-05-16 /pmc/articles/PMC10233573/ /pubmed/37192335 http://dx.doi.org/10.1021/acs.analchem.3c00471 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Thoben, Christian Raddatz, Christian-Robert Tataroglu, Aykut Kobelt, Tim Zimmermann, Stefan How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers |
title | How to Improve
the Resolving Power of Compact Electrospray
Ionization Ion Mobility Spectrometers |
title_full | How to Improve
the Resolving Power of Compact Electrospray
Ionization Ion Mobility Spectrometers |
title_fullStr | How to Improve
the Resolving Power of Compact Electrospray
Ionization Ion Mobility Spectrometers |
title_full_unstemmed | How to Improve
the Resolving Power of Compact Electrospray
Ionization Ion Mobility Spectrometers |
title_short | How to Improve
the Resolving Power of Compact Electrospray
Ionization Ion Mobility Spectrometers |
title_sort | how to improve
the resolving power of compact electrospray
ionization ion mobility spectrometers |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233573/ https://www.ncbi.nlm.nih.gov/pubmed/37192335 http://dx.doi.org/10.1021/acs.analchem.3c00471 |
work_keys_str_mv | AT thobenchristian howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers AT raddatzchristianrobert howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers AT tatarogluaykut howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers AT kobelttim howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers AT zimmermannstefan howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers |