Cargando…

How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers

[Image: see text] Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width o...

Descripción completa

Detalles Bibliográficos
Autores principales: Thoben, Christian, Raddatz, Christian-Robert, Tataroglu, Aykut, Kobelt, Tim, Zimmermann, Stefan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2023
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233573/
https://www.ncbi.nlm.nih.gov/pubmed/37192335
http://dx.doi.org/10.1021/acs.analchem.3c00471
_version_ 1785052285312696320
author Thoben, Christian
Raddatz, Christian-Robert
Tataroglu, Aykut
Kobelt, Tim
Zimmermann, Stefan
author_facet Thoben, Christian
Raddatz, Christian-Robert
Tataroglu, Aykut
Kobelt, Tim
Zimmermann, Stefan
author_sort Thoben, Christian
collection PubMed
description [Image: see text] Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width of the injected ion packet leads to improved resolving power, higher peak amplitudes when operating the IMS at optimum resolving power, and thus a better signal-to-noise ratio despite the reduced number of injected ions. Hereby, the performance of electrospray ionization (ESI)-IMS can be considerably improved. By setting the ion shutter opening time to just 5 μs and slightly increasing the pressure, a high resolving power R(P) > 150 can be achieved with a given drift length of just 75 mm. At such high resolving power, even a mixture of the herbicides isoproturon and chlortoluron having similar ion mobility can be well separated despite short drift length.
format Online
Article
Text
id pubmed-10233573
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-102335732023-06-02 How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers Thoben, Christian Raddatz, Christian-Robert Tataroglu, Aykut Kobelt, Tim Zimmermann, Stefan Anal Chem [Image: see text] Every drift tube ion mobility spectrometer (IMS) has an optimum drift voltage to reach maximum resolving power. This optimum depends, among other things, on the temporal and spatial width of the injected ion packet and the pressure within the IMS. A reduction of the spatial width of the injected ion packet leads to improved resolving power, higher peak amplitudes when operating the IMS at optimum resolving power, and thus a better signal-to-noise ratio despite the reduced number of injected ions. Hereby, the performance of electrospray ionization (ESI)-IMS can be considerably improved. By setting the ion shutter opening time to just 5 μs and slightly increasing the pressure, a high resolving power R(P) > 150 can be achieved with a given drift length of just 75 mm. At such high resolving power, even a mixture of the herbicides isoproturon and chlortoluron having similar ion mobility can be well separated despite short drift length. American Chemical Society 2023-05-16 /pmc/articles/PMC10233573/ /pubmed/37192335 http://dx.doi.org/10.1021/acs.analchem.3c00471 Text en © 2023 The Authors. Published by American Chemical Society https://creativecommons.org/licenses/by/4.0/Permits the broadest form of re-use including for commercial purposes, provided that author attribution and integrity are maintained (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Thoben, Christian
Raddatz, Christian-Robert
Tataroglu, Aykut
Kobelt, Tim
Zimmermann, Stefan
How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
title How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
title_full How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
title_fullStr How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
title_full_unstemmed How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
title_short How to Improve the Resolving Power of Compact Electrospray Ionization Ion Mobility Spectrometers
title_sort how to improve the resolving power of compact electrospray ionization ion mobility spectrometers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233573/
https://www.ncbi.nlm.nih.gov/pubmed/37192335
http://dx.doi.org/10.1021/acs.analchem.3c00471
work_keys_str_mv AT thobenchristian howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers
AT raddatzchristianrobert howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers
AT tatarogluaykut howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers
AT kobelttim howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers
AT zimmermannstefan howtoimprovetheresolvingpowerofcompactelectrosprayionizationionmobilityspectrometers