Cargando…

Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia

PURPOSE: To investigate the binocular summation (BiS) of visual acuity (VA) and contrast sensitivity (CS) in children with intermittent exotropia (IXT) before and after surgery and to probe the relationship between the two BiS phenomena and corresponding influencing factors. METHODS: This prospectiv...

Descripción completa

Detalles Bibliográficos
Autores principales: Liao, Jun, Li, Yueping, Zhang, Wei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233972/
https://www.ncbi.nlm.nih.gov/pubmed/37264304
http://dx.doi.org/10.1186/s12886-023-02961-x
_version_ 1785052376372084736
author Liao, Jun
Li, Yueping
Zhang, Wei
author_facet Liao, Jun
Li, Yueping
Zhang, Wei
author_sort Liao, Jun
collection PubMed
description PURPOSE: To investigate the binocular summation (BiS) of visual acuity (VA) and contrast sensitivity (CS) in children with intermittent exotropia (IXT) before and after surgery and to probe the relationship between the two BiS phenomena and corresponding influencing factors. METHODS: This prospective study included 21 IXT children (11 males and 10 females; aged 6–13 years) who underwent strabismus surgery in Tianjin Eye Hospital from January to April 2022. The visual function was assessed preoperatively and 2.95 ± 0.14 months postoperatively, including monocular/ binocular visual acuity (MVA/BVA) at 100% contrast and 2.5% contrast as well as monocular/binocular contrast sensitivity (MCS/BCS), deviation, near and distant stereopsis, and fusion. RESULTS: All patients had postoperative deviation ranging from 0 to -4 PD. Either preoperative or postoperative BVA at 2.5% contrast was superior to the MVA. The postoperative BiS at 2.5% contrast was significantly superior to the preoperative BiS for 2.5% contrast and postoperative BiS for 100% contrast (P < 0.05). Except for 3 c/d, the MCS and BCS at 6 c/d, 12 c/d and 18 c/d spatial frequencies were all notably improved postoperatively. The postoperative binocular summation ratio of CS (BSR) was highest while interocular difference ratio of CS (IOR) was the lowest at 6 c/d among 4 spatial frequencies. The deviation, distant and near stereopsis, and fusion performance were all remarkably improved after surgery (p = 0.001; p = 0.041; p = 0.000), all of which were not related to BVA at 2.5% contrast, BiS, BSC and BSR. The BCS at middle and high frequencies (6 c/ds, 12 c/ds, and 18 c/ds) was significantly negatively correlated with the BVA at 2.5% contrast, and BSR was irrelevant to the corresponding IOR across different spatial frequencies. CONCLUSION: BVA at low contrast and BCS examinations were not equivalent to stereopsis and fusion status, which contributed to the evaluation of binocular function in the real environment and in the different aspects. BVA in 2.5% contrast is related with BCS in moderate and high spacial frequencies (especially 18c/d) but BCS in 6c/d presents more binocular summation of contrast sensitivity. MCS, BCS and the BSR persist inhibition at 3c/d after surgery. The improvement of BCS is better than that of BSR to evaluate the binouclar function in IXT. Those two methods showed different sensitivities to impairment and rehabilitation of binocular summation and inhibition. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-023-02961-x.
format Online
Article
Text
id pubmed-10233972
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-102339722023-06-02 Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia Liao, Jun Li, Yueping Zhang, Wei BMC Ophthalmol Research PURPOSE: To investigate the binocular summation (BiS) of visual acuity (VA) and contrast sensitivity (CS) in children with intermittent exotropia (IXT) before and after surgery and to probe the relationship between the two BiS phenomena and corresponding influencing factors. METHODS: This prospective study included 21 IXT children (11 males and 10 females; aged 6–13 years) who underwent strabismus surgery in Tianjin Eye Hospital from January to April 2022. The visual function was assessed preoperatively and 2.95 ± 0.14 months postoperatively, including monocular/ binocular visual acuity (MVA/BVA) at 100% contrast and 2.5% contrast as well as monocular/binocular contrast sensitivity (MCS/BCS), deviation, near and distant stereopsis, and fusion. RESULTS: All patients had postoperative deviation ranging from 0 to -4 PD. Either preoperative or postoperative BVA at 2.5% contrast was superior to the MVA. The postoperative BiS at 2.5% contrast was significantly superior to the preoperative BiS for 2.5% contrast and postoperative BiS for 100% contrast (P < 0.05). Except for 3 c/d, the MCS and BCS at 6 c/d, 12 c/d and 18 c/d spatial frequencies were all notably improved postoperatively. The postoperative binocular summation ratio of CS (BSR) was highest while interocular difference ratio of CS (IOR) was the lowest at 6 c/d among 4 spatial frequencies. The deviation, distant and near stereopsis, and fusion performance were all remarkably improved after surgery (p = 0.001; p = 0.041; p = 0.000), all of which were not related to BVA at 2.5% contrast, BiS, BSC and BSR. The BCS at middle and high frequencies (6 c/ds, 12 c/ds, and 18 c/ds) was significantly negatively correlated with the BVA at 2.5% contrast, and BSR was irrelevant to the corresponding IOR across different spatial frequencies. CONCLUSION: BVA at low contrast and BCS examinations were not equivalent to stereopsis and fusion status, which contributed to the evaluation of binocular function in the real environment and in the different aspects. BVA in 2.5% contrast is related with BCS in moderate and high spacial frequencies (especially 18c/d) but BCS in 6c/d presents more binocular summation of contrast sensitivity. MCS, BCS and the BSR persist inhibition at 3c/d after surgery. The improvement of BCS is better than that of BSR to evaluate the binouclar function in IXT. Those two methods showed different sensitivities to impairment and rehabilitation of binocular summation and inhibition. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12886-023-02961-x. BioMed Central 2023-06-01 /pmc/articles/PMC10233972/ /pubmed/37264304 http://dx.doi.org/10.1186/s12886-023-02961-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Liao, Jun
Li, Yueping
Zhang, Wei
Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
title Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
title_full Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
title_fullStr Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
title_full_unstemmed Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
title_short Binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
title_sort binocular summation of visual acuity and contrast sensitivity in children with intermittent exotropia
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10233972/
https://www.ncbi.nlm.nih.gov/pubmed/37264304
http://dx.doi.org/10.1186/s12886-023-02961-x
work_keys_str_mv AT liaojun binocularsummationofvisualacuityandcontrastsensitivityinchildrenwithintermittentexotropia
AT liyueping binocularsummationofvisualacuityandcontrastsensitivityinchildrenwithintermittentexotropia
AT zhangwei binocularsummationofvisualacuityandcontrastsensitivityinchildrenwithintermittentexotropia