Cargando…
Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography
Anterior hip coverage is important for hip stability. As a parameter of anterior hip coverage, the anterior center-edge angle on false-profile radiograph (ACEA FP) is associated with clinical outcomes. With the widespread application of computed tomography (CT), the anterior center-edge angle on CT...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10234381/ https://www.ncbi.nlm.nih.gov/pubmed/37275833 http://dx.doi.org/10.1093/jhps/hnac048 |
_version_ | 1785052480504070144 |
---|---|
author | Cheng, Hui Zhang, Liqiang Luo, Dianzhong Ren, Ningtao Zhang, Zhendong Gu, Wang Hu, Yongcheng Zhang, Hong |
author_facet | Cheng, Hui Zhang, Liqiang Luo, Dianzhong Ren, Ningtao Zhang, Zhendong Gu, Wang Hu, Yongcheng Zhang, Hong |
author_sort | Cheng, Hui |
collection | PubMed |
description | Anterior hip coverage is important for hip stability. As a parameter of anterior hip coverage, the anterior center-edge angle on false-profile radiograph (ACEA FP) is associated with clinical outcomes. With the widespread application of computed tomography (CT), the anterior center-edge angle on CT (ACEA CT) has also been used to measure anterior hip coverage. Little is known about the reproducibility of the ACEA FP and ACEA CT in patients with hip dysplasia or the correlation between the ACEA CT and ACEA FP. In total, 49 hips of 49 patients who underwent periacetabular osteotomy in our center were included. The lateral center-edge angle, Tönnis angle, ACEA FP and ACEA CT were determined. We assessed the intraobserver and interobserver reliability of the ACEA FP and ACEA CT, the effect of the Tönnis angle on the reliability of the ACEA FP and ACEA CT and the correlation between the ACEA CT and ACEA FP. The intraobserver and interobserver interclass correlation coefficients of the ACEA FP were good, and those of the ACEA CT were very good. The Tönnis angle was weakly correlated with inconsistent ACEA FP measurements (P = 0.008) but not with inconsistent ACEA CT measurements (P = 0.600). No correlation between ACEA FP and ACEA CT measurements was observed (P = 0.213–0.665). The reproducibility of the ACEA CT is more consistent than that of the ACEA FP. The oblique acetabular roof had an effect on determining the ACEA FP but not on determining the ACEA CT. No correlation was observed between the measured ACEA FP and ACEA CT values, so the clinical evidence obtained from the ACEA FP cannot be directly applied to the ACEA CT. |
format | Online Article Text |
id | pubmed-10234381 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-102343812023-06-02 Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography Cheng, Hui Zhang, Liqiang Luo, Dianzhong Ren, Ningtao Zhang, Zhendong Gu, Wang Hu, Yongcheng Zhang, Hong J Hip Preserv Surg Research Article Anterior hip coverage is important for hip stability. As a parameter of anterior hip coverage, the anterior center-edge angle on false-profile radiograph (ACEA FP) is associated with clinical outcomes. With the widespread application of computed tomography (CT), the anterior center-edge angle on CT (ACEA CT) has also been used to measure anterior hip coverage. Little is known about the reproducibility of the ACEA FP and ACEA CT in patients with hip dysplasia or the correlation between the ACEA CT and ACEA FP. In total, 49 hips of 49 patients who underwent periacetabular osteotomy in our center were included. The lateral center-edge angle, Tönnis angle, ACEA FP and ACEA CT were determined. We assessed the intraobserver and interobserver reliability of the ACEA FP and ACEA CT, the effect of the Tönnis angle on the reliability of the ACEA FP and ACEA CT and the correlation between the ACEA CT and ACEA FP. The intraobserver and interobserver interclass correlation coefficients of the ACEA FP were good, and those of the ACEA CT were very good. The Tönnis angle was weakly correlated with inconsistent ACEA FP measurements (P = 0.008) but not with inconsistent ACEA CT measurements (P = 0.600). No correlation between ACEA FP and ACEA CT measurements was observed (P = 0.213–0.665). The reproducibility of the ACEA CT is more consistent than that of the ACEA FP. The oblique acetabular roof had an effect on determining the ACEA FP but not on determining the ACEA CT. No correlation was observed between the measured ACEA FP and ACEA CT values, so the clinical evidence obtained from the ACEA FP cannot be directly applied to the ACEA CT. Oxford University Press 2023-03-06 /pmc/articles/PMC10234381/ /pubmed/37275833 http://dx.doi.org/10.1093/jhps/hnac048 Text en © The Author(s) 2023. Published by Oxford University Press. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Cheng, Hui Zhang, Liqiang Luo, Dianzhong Ren, Ningtao Zhang, Zhendong Gu, Wang Hu, Yongcheng Zhang, Hong Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography |
title | Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography |
title_full | Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography |
title_fullStr | Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography |
title_full_unstemmed | Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography |
title_short | Determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on Lequesne’s false-profile radiograph and on computed tomography |
title_sort | determining anterior hip coverage in patients with hip dysplasia using the anterior center-edge angle on lequesne’s false-profile radiograph and on computed tomography |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10234381/ https://www.ncbi.nlm.nih.gov/pubmed/37275833 http://dx.doi.org/10.1093/jhps/hnac048 |
work_keys_str_mv | AT chenghui determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT zhangliqiang determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT luodianzhong determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT renningtao determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT zhangzhendong determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT guwang determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT huyongcheng determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography AT zhanghong determininganteriorhipcoverageinpatientswithhipdysplasiausingtheanteriorcenteredgeangleonlequesnesfalseprofileradiographandoncomputedtomography |