Limitations of transcutaneous carbon dioxide monitoring in apneic oxygenation

BACKGROUND: High-flow nasal oxygenation is increasingly used during sedation procedures and general anesthesia in apneic patients. Transcutaneous CO(2) (p(tc)CO(2))-monitoring is used to monitor hypercapnia. This study investigated p(tc)CO(2)-monitoring during apneic oxygenation. METHODS: We include...