Cargando…

Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization

In this study, we designed and manufactured a posterior lumbar interbody fusion cage for osteoporosis patients using 3D-printing. The cage structure conforms to the anatomical endplate’s curved surface for stress transmission and internal lattice design for bone growth. Finite element (FE) analysis...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Shao-Fu, Chang, Chun-Ming, Liao, Chi-Yang, Chan, Yi-Ting, Li, Zi-Yi, Lin, Chun-Li
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Whioce Publishing Pte. Ltd. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10236481/
https://www.ncbi.nlm.nih.gov/pubmed/37273986
http://dx.doi.org/10.18063/ijb.697
_version_ 1785052932505337856
author Huang, Shao-Fu
Chang, Chun-Ming
Liao, Chi-Yang
Chan, Yi-Ting
Li, Zi-Yi
Lin, Chun-Li
author_facet Huang, Shao-Fu
Chang, Chun-Ming
Liao, Chi-Yang
Chan, Yi-Ting
Li, Zi-Yi
Lin, Chun-Li
author_sort Huang, Shao-Fu
collection PubMed
description In this study, we designed and manufactured a posterior lumbar interbody fusion cage for osteoporosis patients using 3D-printing. The cage structure conforms to the anatomical endplate’s curved surface for stress transmission and internal lattice design for bone growth. Finite element (FE) analysis and weight topology optimization under different lumbar spine activity ratios were integrated to design the curved surface (CS-type) cage using the endplate surface morphology statistical results from the osteoporosis patients. The CS-type and plate (P-type) cage biomechanical behaviors under different daily activities were compared by performing non-linear FE analysis. A gyroid lattice with 0.25 spiral wall thickness was then designed in the internal cavity of the CS-type cage. The CS-cage was manufactured using metal 3D printing to conduct in vitro biomechanical tests. The FE analysis result showed that the maximum stress values at the inferior L3 and superior L4 endplates under all daily activities for the P-type cage implantation model were all higher than those for the CS-type cage. Fracture might occur in the P-type cage because the maximum stresses found in the endplates exceeded its ultimate strength (about 10 MPa) under flexion, torsion and bending loads. The yield load and stiffness of our designed CS-type cage fall into the optional acceptance criteria for the ISO 23089 standard under all load conditions. This study approved a posterior lumbar interbody fusion cage designed to have osteoporosis anatomical curved surface with internal lattice that can achieve appropriate structural strength, better stress transmission between the endplate and cage, and biomechanically tested strength that meets the standard requirements for marketed cages.
format Online
Article
Text
id pubmed-10236481
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Whioce Publishing Pte. Ltd.
record_format MEDLINE/PubMed
spelling pubmed-102364812023-06-03 Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization Huang, Shao-Fu Chang, Chun-Ming Liao, Chi-Yang Chan, Yi-Ting Li, Zi-Yi Lin, Chun-Li Int J Bioprint Research Article In this study, we designed and manufactured a posterior lumbar interbody fusion cage for osteoporosis patients using 3D-printing. The cage structure conforms to the anatomical endplate’s curved surface for stress transmission and internal lattice design for bone growth. Finite element (FE) analysis and weight topology optimization under different lumbar spine activity ratios were integrated to design the curved surface (CS-type) cage using the endplate surface morphology statistical results from the osteoporosis patients. The CS-type and plate (P-type) cage biomechanical behaviors under different daily activities were compared by performing non-linear FE analysis. A gyroid lattice with 0.25 spiral wall thickness was then designed in the internal cavity of the CS-type cage. The CS-cage was manufactured using metal 3D printing to conduct in vitro biomechanical tests. The FE analysis result showed that the maximum stress values at the inferior L3 and superior L4 endplates under all daily activities for the P-type cage implantation model were all higher than those for the CS-type cage. Fracture might occur in the P-type cage because the maximum stresses found in the endplates exceeded its ultimate strength (about 10 MPa) under flexion, torsion and bending loads. The yield load and stiffness of our designed CS-type cage fall into the optional acceptance criteria for the ISO 23089 standard under all load conditions. This study approved a posterior lumbar interbody fusion cage designed to have osteoporosis anatomical curved surface with internal lattice that can achieve appropriate structural strength, better stress transmission between the endplate and cage, and biomechanically tested strength that meets the standard requirements for marketed cages. Whioce Publishing Pte. Ltd. 2023-03-01 /pmc/articles/PMC10236481/ /pubmed/37273986 http://dx.doi.org/10.18063/ijb.697 Text en Copyright: © 2023 Author(s). https://creativecommons.org/licenses/by-nc/4.0/This is an Open-Access article distributed under the terms of the Creative Commons Attribution-Noncommercial License, permitting all noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Huang, Shao-Fu
Chang, Chun-Ming
Liao, Chi-Yang
Chan, Yi-Ting
Li, Zi-Yi
Lin, Chun-Li
Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
title Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
title_full Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
title_fullStr Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
title_full_unstemmed Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
title_short Biomechanical evaluation of an osteoporotic anatomical 3D printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
title_sort biomechanical evaluation of an osteoporotic anatomical 3d printed posterior lumbar interbody fusion cage with internal lattice design based on weighted topology optimization
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10236481/
https://www.ncbi.nlm.nih.gov/pubmed/37273986
http://dx.doi.org/10.18063/ijb.697
work_keys_str_mv AT huangshaofu biomechanicalevaluationofanosteoporoticanatomical3dprintedposteriorlumbarinterbodyfusioncagewithinternallatticedesignbasedonweightedtopologyoptimization
AT changchunming biomechanicalevaluationofanosteoporoticanatomical3dprintedposteriorlumbarinterbodyfusioncagewithinternallatticedesignbasedonweightedtopologyoptimization
AT liaochiyang biomechanicalevaluationofanosteoporoticanatomical3dprintedposteriorlumbarinterbodyfusioncagewithinternallatticedesignbasedonweightedtopologyoptimization
AT chanyiting biomechanicalevaluationofanosteoporoticanatomical3dprintedposteriorlumbarinterbodyfusioncagewithinternallatticedesignbasedonweightedtopologyoptimization
AT liziyi biomechanicalevaluationofanosteoporoticanatomical3dprintedposteriorlumbarinterbodyfusioncagewithinternallatticedesignbasedonweightedtopologyoptimization
AT linchunli biomechanicalevaluationofanosteoporoticanatomical3dprintedposteriorlumbarinterbodyfusioncagewithinternallatticedesignbasedonweightedtopologyoptimization