Cargando…
Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review
BACKGROUND: Vertical root fractures (VRFs) sometimes occur in endodontically treated teeth. They have a difficult diagnosis and a dismal result. The objective of this review was to evaluate the diagnostic performance of cone-beam computed tomography (CBCT) for detecting VRFs in teeth that had underg...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10236739/ https://www.ncbi.nlm.nih.gov/pubmed/37264339 http://dx.doi.org/10.1186/s12880-023-01024-3 |
_version_ | 1785053009288364032 |
---|---|
author | Habibzadeh, Sareh Ghoncheh, Zahra Kabiri, Pedram Mosaddad, Seyed Ali |
author_facet | Habibzadeh, Sareh Ghoncheh, Zahra Kabiri, Pedram Mosaddad, Seyed Ali |
author_sort | Habibzadeh, Sareh |
collection | PubMed |
description | BACKGROUND: Vertical root fractures (VRFs) sometimes occur in endodontically treated teeth. They have a difficult diagnosis and a dismal result. The objective of this review was to evaluate the diagnostic performance of cone-beam computed tomography (CBCT) for detecting VRFs in teeth that had undergone endodontic treatment. METHODS: Literature was reviewed from Web of Science, PubMed, Cochrane Review, SCOPUS, and Embase databases between 2000 and 2022. The searched keywords included "endodontically treated teeth," "cone-beam computed tomography," "CBCT," "tooth fracture," "vertical root fracture," "VRF," "accuracy," "sensitivity," and "specificity." Only articles in the English language were included. The final analysis included 20 papers that satisfied the eligibility requirements. RESULTS: The overall mean ± SD values (%) for the diagnostic sensitivity and specificity of CBCT for detection of VRFs in endodontically treated teeth in the presence of root-filling materials without an intracanal post were 71.50 ± 22.19 and 75.64 ± 19.41, respectively. The overall mean (SD) value (%) for the sensitivity of CBCT for the detection of VRFs in the presence of root-filling materials and intracanal posts was 72.76 (18.73), while the mean (SD) specificity was 75.44 (18.26). The accuracy of CBCT (mean ± SD) was 78.47 ± 17.19% and 74.02 ± 10.64%, respectively, for teeth without intracanal posts and those with posts. CONCLUSIONS: Further clinical research is needed to validate the optimum efficiency of CBCT as a diagnostic technique for detecting VRFs in teeth that have had endodontic treatment, given the low sensitivity, significant heterogeneity of studies, and lack of in-vivo studies on the subject. |
format | Online Article Text |
id | pubmed-10236739 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102367392023-06-03 Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review Habibzadeh, Sareh Ghoncheh, Zahra Kabiri, Pedram Mosaddad, Seyed Ali BMC Med Imaging Research BACKGROUND: Vertical root fractures (VRFs) sometimes occur in endodontically treated teeth. They have a difficult diagnosis and a dismal result. The objective of this review was to evaluate the diagnostic performance of cone-beam computed tomography (CBCT) for detecting VRFs in teeth that had undergone endodontic treatment. METHODS: Literature was reviewed from Web of Science, PubMed, Cochrane Review, SCOPUS, and Embase databases between 2000 and 2022. The searched keywords included "endodontically treated teeth," "cone-beam computed tomography," "CBCT," "tooth fracture," "vertical root fracture," "VRF," "accuracy," "sensitivity," and "specificity." Only articles in the English language were included. The final analysis included 20 papers that satisfied the eligibility requirements. RESULTS: The overall mean ± SD values (%) for the diagnostic sensitivity and specificity of CBCT for detection of VRFs in endodontically treated teeth in the presence of root-filling materials without an intracanal post were 71.50 ± 22.19 and 75.64 ± 19.41, respectively. The overall mean (SD) value (%) for the sensitivity of CBCT for the detection of VRFs in the presence of root-filling materials and intracanal posts was 72.76 (18.73), while the mean (SD) specificity was 75.44 (18.26). The accuracy of CBCT (mean ± SD) was 78.47 ± 17.19% and 74.02 ± 10.64%, respectively, for teeth without intracanal posts and those with posts. CONCLUSIONS: Further clinical research is needed to validate the optimum efficiency of CBCT as a diagnostic technique for detecting VRFs in teeth that have had endodontic treatment, given the low sensitivity, significant heterogeneity of studies, and lack of in-vivo studies on the subject. BioMed Central 2023-06-01 /pmc/articles/PMC10236739/ /pubmed/37264339 http://dx.doi.org/10.1186/s12880-023-01024-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Habibzadeh, Sareh Ghoncheh, Zahra Kabiri, Pedram Mosaddad, Seyed Ali Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
title | Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
title_full | Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
title_fullStr | Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
title_full_unstemmed | Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
title_short | Diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
title_sort | diagnostic efficacy of cone-beam computed tomography for detection of vertical root fractures in endodontically treated teeth: a systematic review |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10236739/ https://www.ncbi.nlm.nih.gov/pubmed/37264339 http://dx.doi.org/10.1186/s12880-023-01024-3 |
work_keys_str_mv | AT habibzadehsareh diagnosticefficacyofconebeamcomputedtomographyfordetectionofverticalrootfracturesinendodonticallytreatedteethasystematicreview AT ghonchehzahra diagnosticefficacyofconebeamcomputedtomographyfordetectionofverticalrootfracturesinendodonticallytreatedteethasystematicreview AT kabiripedram diagnosticefficacyofconebeamcomputedtomographyfordetectionofverticalrootfracturesinendodonticallytreatedteethasystematicreview AT mosaddadseyedali diagnosticefficacyofconebeamcomputedtomographyfordetectionofverticalrootfracturesinendodonticallytreatedteethasystematicreview |