A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods

The point shear wave elastography and supersonic shear imaging methods were compared regarding incorrect measurements during the liver examinations. A report-based, single-center, retrospective analysis of 425 liver elastography examinations was performed. A lower success ratio was observed for the...

Descripción completa

Detalles Bibliográficos
Autores principales: Cebula, Maciej, Kufel, Jakub, Gruszczyńska, Katarzyna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10237685/
https://www.ncbi.nlm.nih.gov/pubmed/37266598
http://dx.doi.org/10.1097/MD.0000000000033964
_version_ 1785053197116637184
author Cebula, Maciej
Kufel, Jakub
Gruszczyńska, Katarzyna
author_facet Cebula, Maciej
Kufel, Jakub
Gruszczyńska, Katarzyna
author_sort Cebula, Maciej
collection PubMed
description The point shear wave elastography and supersonic shear imaging methods were compared regarding incorrect measurements during the liver examinations. A report-based, single-center, retrospective analysis of 425 liver elastography examinations was performed. A lower success ratio was observed for the point shear wave elastography method, as well as the older and obese patients pre-dominated in non-diagnostic studies. In our center experience, it is easier to obtain diagnostic data using the supersonic shear imaging method. However, further investigation of the subject is needed.
format Online
Article
Text
id pubmed-10237685
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-102376852023-06-03 A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods Cebula, Maciej Kufel, Jakub Gruszczyńska, Katarzyna Medicine (Baltimore) 6800 The point shear wave elastography and supersonic shear imaging methods were compared regarding incorrect measurements during the liver examinations. A report-based, single-center, retrospective analysis of 425 liver elastography examinations was performed. A lower success ratio was observed for the point shear wave elastography method, as well as the older and obese patients pre-dominated in non-diagnostic studies. In our center experience, it is easier to obtain diagnostic data using the supersonic shear imaging method. However, further investigation of the subject is needed. Lippincott Williams & Wilkins 2023-06-02 /pmc/articles/PMC10237685/ /pubmed/37266598 http://dx.doi.org/10.1097/MD.0000000000033964 Text en Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License 4.0 (CCBY) (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle 6800
Cebula, Maciej
Kufel, Jakub
Gruszczyńska, Katarzyna
A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods
title A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods
title_full A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods
title_fullStr A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods
title_full_unstemmed A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods
title_short A single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pSWE and SSI ultrasound elastography methods
title_sort single-center, retrospective, cross-sectional study comparing the number of non-diagnostic measurements ratio in the pswe and ssi ultrasound elastography methods
topic 6800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10237685/
https://www.ncbi.nlm.nih.gov/pubmed/37266598
http://dx.doi.org/10.1097/MD.0000000000033964
work_keys_str_mv AT cebulamaciej asinglecenterretrospectivecrosssectionalstudycomparingthenumberofnondiagnosticmeasurementsratiointhepsweandssiultrasoundelastographymethods
AT kufeljakub asinglecenterretrospectivecrosssectionalstudycomparingthenumberofnondiagnosticmeasurementsratiointhepsweandssiultrasoundelastographymethods
AT gruszczynskakatarzyna asinglecenterretrospectivecrosssectionalstudycomparingthenumberofnondiagnosticmeasurementsratiointhepsweandssiultrasoundelastographymethods
AT cebulamaciej singlecenterretrospectivecrosssectionalstudycomparingthenumberofnondiagnosticmeasurementsratiointhepsweandssiultrasoundelastographymethods
AT kufeljakub singlecenterretrospectivecrosssectionalstudycomparingthenumberofnondiagnosticmeasurementsratiointhepsweandssiultrasoundelastographymethods
AT gruszczynskakatarzyna singlecenterretrospectivecrosssectionalstudycomparingthenumberofnondiagnosticmeasurementsratiointhepsweandssiultrasoundelastographymethods