Cargando…
Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition
BACKGROUND: The study's objective was to assess the accuracy (trueness and precision) of orthodontic models obtained from crowded and spaced dentition finalized for the production of clear aligners. Four 3D printers featuring different technologies and market segments were used for this purpose...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10239183/ https://www.ncbi.nlm.nih.gov/pubmed/37268910 http://dx.doi.org/10.1186/s12903-023-03025-8 |
_version_ | 1785053445325062144 |
---|---|
author | Grassia, Vincenzo Ronsivalle, Vincenzo Isola, Gaetano Nucci, Ludovica Leonardi, Rosalia Lo Giudice, Antonino |
author_facet | Grassia, Vincenzo Ronsivalle, Vincenzo Isola, Gaetano Nucci, Ludovica Leonardi, Rosalia Lo Giudice, Antonino |
author_sort | Grassia, Vincenzo |
collection | PubMed |
description | BACKGROUND: The study's objective was to assess the accuracy (trueness and precision) of orthodontic models obtained from crowded and spaced dentition finalized for the production of clear aligners. Four 3D printers featuring different technologies and market segments were used for this purpose. METHODS: Two digital master models were obtained from two patients featuring respectively crowded dentition (CM group) and diastema/edentulous spaces (DEM group). The 3D printers tested were: Form 3B (SLA technology, medium-professional segment), Vector 3SP (SLA technology, industrial segment), Asiga Pro 4K65 (DLP technology, high-professional segment), and Anycubic Photon M3 (LCD technology, entry-level segment). Each 3D printed model was scanned and superimposed onto the reference master model and digital deviation analysis was performed to assess the trueness and precision calculated as root mean square (RMS). All data were statistically examined to obtain intra-group and inter-groups comparisons(p 0.05). RESULTS: In both CM and DEM groups, SLA 3D printers (Vector 3SP and Form 3B) showed lower trueness error compared to DLP/LCD technologies (Asiga Pro 4K65, Anycubic Photon M3) (p < 0.001). In general, the entry-level printer (Anycubic Photon M3) showed the greatest trueness error (p < 0.001). Comparing CM and DEM models generated with the same 3D printer, statistically significant differences were found only for Asiga Pro 4k65 and Anycubic Photon M3 printers (p > 0.05). Concerning data of precision, the DLP technology (Asiga Pro 4k65) showed lower error compared to the other 3D printers tested. The trueness and precision errors were within the accepted clinical error for clear aligner manufacturing (< 0.25 mm), with the entry-level 3D printer nearly reaching this value. CONCLUSIONS: The accuracy of orthodontic models generated for clear aligners can be affected by different 3D printer technologies and anatomical characteristics of dental arches. |
format | Online Article Text |
id | pubmed-10239183 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102391832023-06-04 Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition Grassia, Vincenzo Ronsivalle, Vincenzo Isola, Gaetano Nucci, Ludovica Leonardi, Rosalia Lo Giudice, Antonino BMC Oral Health Research BACKGROUND: The study's objective was to assess the accuracy (trueness and precision) of orthodontic models obtained from crowded and spaced dentition finalized for the production of clear aligners. Four 3D printers featuring different technologies and market segments were used for this purpose. METHODS: Two digital master models were obtained from two patients featuring respectively crowded dentition (CM group) and diastema/edentulous spaces (DEM group). The 3D printers tested were: Form 3B (SLA technology, medium-professional segment), Vector 3SP (SLA technology, industrial segment), Asiga Pro 4K65 (DLP technology, high-professional segment), and Anycubic Photon M3 (LCD technology, entry-level segment). Each 3D printed model was scanned and superimposed onto the reference master model and digital deviation analysis was performed to assess the trueness and precision calculated as root mean square (RMS). All data were statistically examined to obtain intra-group and inter-groups comparisons(p 0.05). RESULTS: In both CM and DEM groups, SLA 3D printers (Vector 3SP and Form 3B) showed lower trueness error compared to DLP/LCD technologies (Asiga Pro 4K65, Anycubic Photon M3) (p < 0.001). In general, the entry-level printer (Anycubic Photon M3) showed the greatest trueness error (p < 0.001). Comparing CM and DEM models generated with the same 3D printer, statistically significant differences were found only for Asiga Pro 4k65 and Anycubic Photon M3 printers (p > 0.05). Concerning data of precision, the DLP technology (Asiga Pro 4k65) showed lower error compared to the other 3D printers tested. The trueness and precision errors were within the accepted clinical error for clear aligner manufacturing (< 0.25 mm), with the entry-level 3D printer nearly reaching this value. CONCLUSIONS: The accuracy of orthodontic models generated for clear aligners can be affected by different 3D printer technologies and anatomical characteristics of dental arches. BioMed Central 2023-06-02 /pmc/articles/PMC10239183/ /pubmed/37268910 http://dx.doi.org/10.1186/s12903-023-03025-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Grassia, Vincenzo Ronsivalle, Vincenzo Isola, Gaetano Nucci, Ludovica Leonardi, Rosalia Lo Giudice, Antonino Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
title | Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
title_full | Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
title_fullStr | Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
title_full_unstemmed | Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
title_short | Accuracy (trueness and precision) of 3D printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
title_sort | accuracy (trueness and precision) of 3d printed orthodontic models finalized to clear aligners production, testing crowded and spaced dentition |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10239183/ https://www.ncbi.nlm.nih.gov/pubmed/37268910 http://dx.doi.org/10.1186/s12903-023-03025-8 |
work_keys_str_mv | AT grassiavincenzo accuracytruenessandprecisionof3dprintedorthodonticmodelsfinalizedtoclearalignersproductiontestingcrowdedandspaceddentition AT ronsivallevincenzo accuracytruenessandprecisionof3dprintedorthodonticmodelsfinalizedtoclearalignersproductiontestingcrowdedandspaceddentition AT isolagaetano accuracytruenessandprecisionof3dprintedorthodonticmodelsfinalizedtoclearalignersproductiontestingcrowdedandspaceddentition AT nucciludovica accuracytruenessandprecisionof3dprintedorthodonticmodelsfinalizedtoclearalignersproductiontestingcrowdedandspaceddentition AT leonardirosalia accuracytruenessandprecisionof3dprintedorthodonticmodelsfinalizedtoclearalignersproductiontestingcrowdedandspaceddentition AT logiudiceantonino accuracytruenessandprecisionof3dprintedorthodonticmodelsfinalizedtoclearalignersproductiontestingcrowdedandspaceddentition |