Cargando…
His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis
BACKGROUND: His-Purkinje system pacing (HPSP), including his-bundle pacing (HBP) and left bundle branch area pacing (LBBaP), imitates the natural conduction of the heart as an alternative to biventricular pacing (BVP) in cardiac resynchronization therapy (CRT). However, the feasibility and efficacy...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10239598/ https://www.ncbi.nlm.nih.gov/pubmed/37270513 http://dx.doi.org/10.1186/s12872-023-03307-7 |
_version_ | 1785053521879498752 |
---|---|
author | Wang, Ya Liu, Fangchao Liu, Mengyao Wang, Zefeng Lu, Xiangfeng Huang, Jianfeng Gu, Dongfeng |
author_facet | Wang, Ya Liu, Fangchao Liu, Mengyao Wang, Zefeng Lu, Xiangfeng Huang, Jianfeng Gu, Dongfeng |
author_sort | Wang, Ya |
collection | PubMed |
description | BACKGROUND: His-Purkinje system pacing (HPSP), including his-bundle pacing (HBP) and left bundle branch area pacing (LBBaP), imitates the natural conduction of the heart as an alternative to biventricular pacing (BVP) in cardiac resynchronization therapy (CRT). However, the feasibility and efficacy of HPSP were currently only evidenced by studies with a limited sample size, so this study aimed to provide a comprehensive assessment through a systematic review and meta-analysis. METHODS: In order to compare the clinical outcomes associated with HPSP and BVP in patients for CRT, PubMed, EMBASE, Cochrane Library and Web of Science database were searched from inception to April 10, 2023. Clinical outcomes of interest including QRS duration (QRSd), left ventricular (LV) function and New York Heart Association (NYHA) functional classification, pacing threshold, echocardiographic and clinical response, hospitalization rate of HF and all-cause mortality were also extracted and summarized for meta-analysis. RESULTS: A total of 13 studies (ten observational studies and three randomized studies) involving 1,121 patients were finally included. The patients were followed up for 6–27 months. Compared with BVP, CRT patients treated by HPSP presented shorter QRSd [mean difference (MD): -26.23 ms, 95% confidence interval (CI): -34.54 to -17.92, P < 0.001, I(2) = 91%], greater LV functional improvement with increased left ventricular ejection fraction (LVEF) (MD: 6.01, 95% CI: 4.81 to 7.22, P < 0.001, I(2) = 0%), decreased left ventricular end-diastolic dimension (LVEDD) (MD: -2.91, 95% CI: -4.86 to -0.95, P = 0.004, I(2) = 35%), and more improved NYHA functional classification (MD: -0.45, 95% CI: -0.67 to -0.23, P < 0.001, I(2) = 70%). In addition, HPSP was more likely to have higher echocardiographic [odds ratio (OR): 2.76, 95% CI: 1.74 to 4.39, P < 0.001, I(2) = 0%], clinical (OR: 2.10, 95% CI: 1.16 to 3.80, P = 0.01, I(2) = 0%) and super clinical (OR: 3.17, 95% CI: 2.09 to 4.79, P < 0.001, I(2) = 0%) responses than BVP, and a lower hospitalization rate of HF (OR: 0.34, 95% CI: 0.22 to 0.51, P < 0.001, I(2) = 0%), while presented no difference (OR: 0.68, 95% CI: 0.44 to 1.06, P = 0.09, I(2) = 0%) in all-cause mortality compared with BVP. With threshold change taking into account, BVP was less stable than LBBaP (MD: -0.12 V, 95% CI: -0.22 to -0.03, P = 0.01, I(2) = 57%), but had no difference with HBP (MD: 0.11 V, 95% CI: -0.09 to 0.31, P = 0.28, I(2) = 0%). CONCLUSION: The present findings suggested that HPSP was associated with greater improvement of cardiac function in patients with indication for CRT and was a potential alternative to BVP to achieve physiological pacing through native his-purkinje system. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-023-03307-7. |
format | Online Article Text |
id | pubmed-10239598 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102395982023-06-05 His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis Wang, Ya Liu, Fangchao Liu, Mengyao Wang, Zefeng Lu, Xiangfeng Huang, Jianfeng Gu, Dongfeng BMC Cardiovasc Disord Research BACKGROUND: His-Purkinje system pacing (HPSP), including his-bundle pacing (HBP) and left bundle branch area pacing (LBBaP), imitates the natural conduction of the heart as an alternative to biventricular pacing (BVP) in cardiac resynchronization therapy (CRT). However, the feasibility and efficacy of HPSP were currently only evidenced by studies with a limited sample size, so this study aimed to provide a comprehensive assessment through a systematic review and meta-analysis. METHODS: In order to compare the clinical outcomes associated with HPSP and BVP in patients for CRT, PubMed, EMBASE, Cochrane Library and Web of Science database were searched from inception to April 10, 2023. Clinical outcomes of interest including QRS duration (QRSd), left ventricular (LV) function and New York Heart Association (NYHA) functional classification, pacing threshold, echocardiographic and clinical response, hospitalization rate of HF and all-cause mortality were also extracted and summarized for meta-analysis. RESULTS: A total of 13 studies (ten observational studies and three randomized studies) involving 1,121 patients were finally included. The patients were followed up for 6–27 months. Compared with BVP, CRT patients treated by HPSP presented shorter QRSd [mean difference (MD): -26.23 ms, 95% confidence interval (CI): -34.54 to -17.92, P < 0.001, I(2) = 91%], greater LV functional improvement with increased left ventricular ejection fraction (LVEF) (MD: 6.01, 95% CI: 4.81 to 7.22, P < 0.001, I(2) = 0%), decreased left ventricular end-diastolic dimension (LVEDD) (MD: -2.91, 95% CI: -4.86 to -0.95, P = 0.004, I(2) = 35%), and more improved NYHA functional classification (MD: -0.45, 95% CI: -0.67 to -0.23, P < 0.001, I(2) = 70%). In addition, HPSP was more likely to have higher echocardiographic [odds ratio (OR): 2.76, 95% CI: 1.74 to 4.39, P < 0.001, I(2) = 0%], clinical (OR: 2.10, 95% CI: 1.16 to 3.80, P = 0.01, I(2) = 0%) and super clinical (OR: 3.17, 95% CI: 2.09 to 4.79, P < 0.001, I(2) = 0%) responses than BVP, and a lower hospitalization rate of HF (OR: 0.34, 95% CI: 0.22 to 0.51, P < 0.001, I(2) = 0%), while presented no difference (OR: 0.68, 95% CI: 0.44 to 1.06, P = 0.09, I(2) = 0%) in all-cause mortality compared with BVP. With threshold change taking into account, BVP was less stable than LBBaP (MD: -0.12 V, 95% CI: -0.22 to -0.03, P = 0.01, I(2) = 57%), but had no difference with HBP (MD: 0.11 V, 95% CI: -0.09 to 0.31, P = 0.28, I(2) = 0%). CONCLUSION: The present findings suggested that HPSP was associated with greater improvement of cardiac function in patients with indication for CRT and was a potential alternative to BVP to achieve physiological pacing through native his-purkinje system. GRAPHICAL ABSTRACT: [Image: see text] SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12872-023-03307-7. BioMed Central 2023-06-03 /pmc/articles/PMC10239598/ /pubmed/37270513 http://dx.doi.org/10.1186/s12872-023-03307-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Wang, Ya Liu, Fangchao Liu, Mengyao Wang, Zefeng Lu, Xiangfeng Huang, Jianfeng Gu, Dongfeng His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
title | His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
title_full | His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
title_fullStr | His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
title_full_unstemmed | His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
title_short | His-Purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
title_sort | his-purkinje system pacing versus biventricular pacing in clinical efficacy: a systematic review and meta-analysis |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10239598/ https://www.ncbi.nlm.nih.gov/pubmed/37270513 http://dx.doi.org/10.1186/s12872-023-03307-7 |
work_keys_str_mv | AT wangya hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis AT liufangchao hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis AT liumengyao hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis AT wangzefeng hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis AT luxiangfeng hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis AT huangjianfeng hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis AT gudongfeng hispurkinjesystempacingversusbiventricularpacinginclinicalefficacyasystematicreviewandmetaanalysis |