Cargando…
Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy
BACKGROUND: This study aimed to compare the clinical efficacy of locking plate and intramedullary nail fixations in the treatment of patients with OTA/AO type 11C proximal humerus fractures. METHODS: We retrospectively analyzed the data of patients with OTA/AO type 11C1.1 and 11C3.1 proximal humerus...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10240685/ https://www.ncbi.nlm.nih.gov/pubmed/37277746 http://dx.doi.org/10.1186/s12891-023-06567-8 |
_version_ | 1785053826654404608 |
---|---|
author | Wang, Minghui Wang, Xiuhui Cai, Pan Guo, Shengyang Fu, Beigang |
author_facet | Wang, Minghui Wang, Xiuhui Cai, Pan Guo, Shengyang Fu, Beigang |
author_sort | Wang, Minghui |
collection | PubMed |
description | BACKGROUND: This study aimed to compare the clinical efficacy of locking plate and intramedullary nail fixations in the treatment of patients with OTA/AO type 11C proximal humerus fractures. METHODS: We retrospectively analyzed the data of patients with OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures who underwent surgery at our institution from June 2012 to June 2017. Perioperative indicators, postoperative morphological parameters of the proximal humerus, and Constant–Murley scores were evaluated and compared. RESULTS: Sixty-eight patients with OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures were enrolled in this study. Overall, 35 patients underwent open reduction and plate screw internal fixation, and 33 patients underwent limited open reduction and locking of the proximal humerus with intramedullary nail internal fixation. The total cohort had a mean follow-up duration of 17.8 months. The mean operation time of the locking plate group was significantly longer than that of the intramedullary nail group (P < 0.05), while the mean bleeding volume was significantly higher in the locking plate group than that in the intramedullary nail group (P < 0.05). The initial neck–shaft angles, final neck–shaft angles, forward flexion ranges, or Constant–Murley scores did not show significant differences between the two groups (P > 0.05). Complications, including screw penetrations, acromion impingement syndrome, infection, and aseptic necrosis of the humeral head, occurred in 8 patients (8/35, 22.8%) in the locking plate group and 5 patients in the intramedullary nail group (5/33, 15.1%; including malunion and acromion impingement syndrome), with no significant difference between the groups (P > 0.05). CONCLUSIONS: Similar satisfactory functional results can be achieved with locking plates and intramedullary nailing for OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures, with no significant difference in the number of complications between these two techniques. However, intramedullary nailing has advantages over locking plates for OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures in terms of operation time and bleeding volume. |
format | Online Article Text |
id | pubmed-10240685 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102406852023-06-06 Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy Wang, Minghui Wang, Xiuhui Cai, Pan Guo, Shengyang Fu, Beigang BMC Musculoskelet Disord Research BACKGROUND: This study aimed to compare the clinical efficacy of locking plate and intramedullary nail fixations in the treatment of patients with OTA/AO type 11C proximal humerus fractures. METHODS: We retrospectively analyzed the data of patients with OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures who underwent surgery at our institution from June 2012 to June 2017. Perioperative indicators, postoperative morphological parameters of the proximal humerus, and Constant–Murley scores were evaluated and compared. RESULTS: Sixty-eight patients with OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures were enrolled in this study. Overall, 35 patients underwent open reduction and plate screw internal fixation, and 33 patients underwent limited open reduction and locking of the proximal humerus with intramedullary nail internal fixation. The total cohort had a mean follow-up duration of 17.8 months. The mean operation time of the locking plate group was significantly longer than that of the intramedullary nail group (P < 0.05), while the mean bleeding volume was significantly higher in the locking plate group than that in the intramedullary nail group (P < 0.05). The initial neck–shaft angles, final neck–shaft angles, forward flexion ranges, or Constant–Murley scores did not show significant differences between the two groups (P > 0.05). Complications, including screw penetrations, acromion impingement syndrome, infection, and aseptic necrosis of the humeral head, occurred in 8 patients (8/35, 22.8%) in the locking plate group and 5 patients in the intramedullary nail group (5/33, 15.1%; including malunion and acromion impingement syndrome), with no significant difference between the groups (P > 0.05). CONCLUSIONS: Similar satisfactory functional results can be achieved with locking plates and intramedullary nailing for OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures, with no significant difference in the number of complications between these two techniques. However, intramedullary nailing has advantages over locking plates for OTA/AO type 11C1.1 and 11C3.1 proximal humerus fractures in terms of operation time and bleeding volume. BioMed Central 2023-06-05 /pmc/articles/PMC10240685/ /pubmed/37277746 http://dx.doi.org/10.1186/s12891-023-06567-8 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Wang, Minghui Wang, Xiuhui Cai, Pan Guo, Shengyang Fu, Beigang Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy |
title | Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy |
title_full | Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy |
title_fullStr | Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy |
title_full_unstemmed | Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy |
title_short | Locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (OTA/AO type 11C): a preliminary comparison of clinical efficacy |
title_sort | locking plate fixation versus intramedullary nail fixation for the treatment of multifragmentary proximal humerus fractures (ota/ao type 11c): a preliminary comparison of clinical efficacy |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10240685/ https://www.ncbi.nlm.nih.gov/pubmed/37277746 http://dx.doi.org/10.1186/s12891-023-06567-8 |
work_keys_str_mv | AT wangminghui lockingplatefixationversusintramedullarynailfixationforthetreatmentofmultifragmentaryproximalhumerusfracturesotaaotype11capreliminarycomparisonofclinicalefficacy AT wangxiuhui lockingplatefixationversusintramedullarynailfixationforthetreatmentofmultifragmentaryproximalhumerusfracturesotaaotype11capreliminarycomparisonofclinicalefficacy AT caipan lockingplatefixationversusintramedullarynailfixationforthetreatmentofmultifragmentaryproximalhumerusfracturesotaaotype11capreliminarycomparisonofclinicalefficacy AT guoshengyang lockingplatefixationversusintramedullarynailfixationforthetreatmentofmultifragmentaryproximalhumerusfracturesotaaotype11capreliminarycomparisonofclinicalefficacy AT fubeigang lockingplatefixationversusintramedullarynailfixationforthetreatmentofmultifragmentaryproximalhumerusfracturesotaaotype11capreliminarycomparisonofclinicalefficacy |