Cargando…
Survival rate and stability of surface-treated and non-surface-treated orthodontic mini-implants: a randomized clinical trial
OBJECTIVES: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. TRIAL DESIGN: Randomized clinical trial with a split-mouth study design...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dental Press International
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10241510/ https://www.ncbi.nlm.nih.gov/pubmed/37283426 http://dx.doi.org/10.1590/2177-6709.28.2.e2321345.oar |
Sumario: | OBJECTIVES: This clinical trial was conducted to evaluate the stability and failure rate of surface-treated orthodontic mini-implants and determine whether they differ from those of non-surface-treated orthodontic mini-implants. TRIAL DESIGN: Randomized clinical trial with a split-mouth study design. SETTING: Department of Orthodontics, SRM Dental College, Chennai. PARTICIPANTS: Patients who required orthodontic mini-implants for anterior retraction in both arches. METHODS: Self-drilling, tapered, titanium orthodontic mini-implants with and without surface treatment were placed in each patient following a split-mouth design. The maximum insertion and removal torques were measured for each implant using a digital torque driver. The failure rates were calculated for each type of mini-implant. RESULTS: The mean maximum insertion torque was 17.9 ± 5.6 Ncm for surface-treated mini-implants and 16.4 ± 9.0 Ncm for non-surface-treated mini-implants. The mean maximum removal torque was 8.1 ± 2.9 Ncm for surface-treated mini-implants and 3.3 ± 1.9 Ncm for non-surface-treated mini-implants. Among the failed implants, 71.4% were non-surface-treated mini-implants and 28.6% were surface-treated mini-implants. CONCLUSION: The insertion torque and failure rate did not differ significantly between the groups, whereas the removal torque was significantly higher in the surface-treated group. Thus, surface treatment using sandblasting and acid etching may improve the secondary stability of self-drilling orthodontic mini-implants. TRIAL REGISTRATION: The trial was registered in the Clinical Trials Registry, India (ICMR NIMS). Registration number: CTRI/2019/10/021718 |
---|