Deep learning phase error correction for cerebrovascular 4D flow MRI
Background phase errors in 4D Flow MRI may negatively impact blood flow quantification. In this study, we assessed their impact on cerebrovascular flow volume measurements, evaluated the benefit of manual image-based correction, and assessed the potential of a convolutional neural network (CNN), a f...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10241936/ https://www.ncbi.nlm.nih.gov/pubmed/37277401 http://dx.doi.org/10.1038/s41598-023-36061-z |
_version_ | 1785054101786066944 |
---|---|
author | Srinivas, Shanmukha Masutani, Evan Norbash, Alexander Hsiao, Albert |
author_facet | Srinivas, Shanmukha Masutani, Evan Norbash, Alexander Hsiao, Albert |
author_sort | Srinivas, Shanmukha |
collection | PubMed |
description | Background phase errors in 4D Flow MRI may negatively impact blood flow quantification. In this study, we assessed their impact on cerebrovascular flow volume measurements, evaluated the benefit of manual image-based correction, and assessed the potential of a convolutional neural network (CNN), a form of deep learning, to directly infer the correction vector field. With IRB waiver of informed consent, we retrospectively identified 96 MRI exams from 48 patients who underwent cerebrovascular 4D Flow MRI from October 2015 to 2020. Flow measurements of the anterior, posterior, and venous circulation were performed to assess inflow-outflow error and the benefit of manual image-based phase error correction. A CNN was then trained to directly infer the phase-error correction field, without segmentation, from 4D Flow volumes to automate correction, reserving from 23 exams for testing. Statistical analyses included Spearman correlation, Bland–Altman, Wilcoxon-signed rank (WSR) and F-tests. Prior to correction, there was strong correlation between inflow and outflow (ρ = 0.833–0.947) measurements with the largest discrepancy in the venous circulation. Manual phase error correction improved inflow-outflow correlation (ρ = 0.945–0.981) and decreased variance (p < 0.001, F-test). Fully automated CNN correction was non-inferior to manual correction with no significant differences in correlation (ρ = 0.971 vs ρ = 0.982) or bias (p = 0.82, Wilcoxon-Signed Rank test) of inflow and outflow measurements. Residual background phase error can impair inflow-outflow consistency of cerebrovascular flow volume measurements. A CNN can be used to directly infer the phase-error vector field to fully automate phase error correction. |
format | Online Article Text |
id | pubmed-10241936 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-102419362023-06-07 Deep learning phase error correction for cerebrovascular 4D flow MRI Srinivas, Shanmukha Masutani, Evan Norbash, Alexander Hsiao, Albert Sci Rep Article Background phase errors in 4D Flow MRI may negatively impact blood flow quantification. In this study, we assessed their impact on cerebrovascular flow volume measurements, evaluated the benefit of manual image-based correction, and assessed the potential of a convolutional neural network (CNN), a form of deep learning, to directly infer the correction vector field. With IRB waiver of informed consent, we retrospectively identified 96 MRI exams from 48 patients who underwent cerebrovascular 4D Flow MRI from October 2015 to 2020. Flow measurements of the anterior, posterior, and venous circulation were performed to assess inflow-outflow error and the benefit of manual image-based phase error correction. A CNN was then trained to directly infer the phase-error correction field, without segmentation, from 4D Flow volumes to automate correction, reserving from 23 exams for testing. Statistical analyses included Spearman correlation, Bland–Altman, Wilcoxon-signed rank (WSR) and F-tests. Prior to correction, there was strong correlation between inflow and outflow (ρ = 0.833–0.947) measurements with the largest discrepancy in the venous circulation. Manual phase error correction improved inflow-outflow correlation (ρ = 0.945–0.981) and decreased variance (p < 0.001, F-test). Fully automated CNN correction was non-inferior to manual correction with no significant differences in correlation (ρ = 0.971 vs ρ = 0.982) or bias (p = 0.82, Wilcoxon-Signed Rank test) of inflow and outflow measurements. Residual background phase error can impair inflow-outflow consistency of cerebrovascular flow volume measurements. A CNN can be used to directly infer the phase-error vector field to fully automate phase error correction. Nature Publishing Group UK 2023-06-05 /pmc/articles/PMC10241936/ /pubmed/37277401 http://dx.doi.org/10.1038/s41598-023-36061-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Srinivas, Shanmukha Masutani, Evan Norbash, Alexander Hsiao, Albert Deep learning phase error correction for cerebrovascular 4D flow MRI |
title | Deep learning phase error correction for cerebrovascular 4D flow MRI |
title_full | Deep learning phase error correction for cerebrovascular 4D flow MRI |
title_fullStr | Deep learning phase error correction for cerebrovascular 4D flow MRI |
title_full_unstemmed | Deep learning phase error correction for cerebrovascular 4D flow MRI |
title_short | Deep learning phase error correction for cerebrovascular 4D flow MRI |
title_sort | deep learning phase error correction for cerebrovascular 4d flow mri |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10241936/ https://www.ncbi.nlm.nih.gov/pubmed/37277401 http://dx.doi.org/10.1038/s41598-023-36061-z |
work_keys_str_mv | AT srinivasshanmukha deeplearningphaseerrorcorrectionforcerebrovascular4dflowmri AT masutanievan deeplearningphaseerrorcorrectionforcerebrovascular4dflowmri AT norbashalexander deeplearningphaseerrorcorrectionforcerebrovascular4dflowmri AT hsiaoalbert deeplearningphaseerrorcorrectionforcerebrovascular4dflowmri |