Capture threshold of bipolar and unipolar pacing of left ventricle via coronary sinus branch: longitudinal study
INTRODUCTION: The aim of this paper is to first monitor the changes in the capture threshold of endovascularly placed leads for left ventricle pacing, second to compare the pacing configurations, and third to verify the effect of Steroid elution for endovascular leads. SAMPLE AND METHOD: The study i...
Autores principales: | Stritecky, Jakub, Kremlacek, Jan, Hanus, Josef, Haman, Ludek, Stritecka, Hana, Simka, Jakub, Parizek, Petr |
---|---|