Cargando…

Hemodynamic and Clinical Outcomes in Redo-Surgical Aortic Valve Replacement vs. Transcatheter Valve-in-Valve

BACKGROUND: Transcatheter valve-in-valve replacement (ViV-TAVR) has emerged as an alternative to redo-surgical aortic valve replacement (Redo-SAVR) for the treatment of failed surgical aortic bioprostheses. However, the benefit of ViV-TAVR compared with Redo-SAVR remains debated with regard to short...

Descripción completa

Detalles Bibliográficos
Autores principales: Hecht, Sébastien, Zenses, Anne-Sophie, Bernard, Jérémy, Tastet, Lionel, Côté, Nancy, de Freitas Campos Guimarães, Leonardo, Paradis, Jean-Michel, Beaudoin, Jonathan, O’Connor, Kim, Bernier, Mathieu, Dumont, Eric, Kalavrouziotis, Dimitri, Delarochellière, Robert, Mohammadi, Siamak, Clavel, Marie-Annick, Rodés-Cabau, Josep, Salaun, Erwan, Pibarot, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10242565/
https://www.ncbi.nlm.nih.gov/pubmed/37288124
http://dx.doi.org/10.1016/j.shj.2022.100106
Descripción
Sumario:BACKGROUND: Transcatheter valve-in-valve replacement (ViV-TAVR) has emerged as an alternative to redo-surgical aortic valve replacement (Redo-SAVR) for the treatment of failed surgical aortic bioprostheses. However, the benefit of ViV-TAVR compared with Redo-SAVR remains debated with regard to short-term hemodynamic results and short- and long-term clinical outcomes. OBJECTIVE: This study aimed to compare short-term hemodynamic performance and long-term clinical outcomes of ViV-TAVR vs. Redo-SAVR in patients treated for surgical aortic bioprosthetic valve failure. METHODS: We retrospectively analyzed the data prospectively collected in 184 patients who underwent Redo-SAVR or ViV-TAVR. Transthoracic echocardiography was performed before and after the procedure and analyzed in an echocardiography core laboratory using the new Valve Academic Research Consortium-3 criteria. An inverse probability of treatment weighting was used to compare the outcomes between both procedures. RESULTS: ViV-TAVR showed lower rate of intended hemodynamic performance (39.2% vs. 67.7%, p < 0.001) at 30 days, which was essentially driven by a higher rate (56.2% vs. 28.8%, p = 0.001) of high residual gradient (mean transvalvular gradient ≥20 mm Hg). Despite a trend for higher 30-day mortality in the Redo-SAVR vs. ViV-TAVR group (8.7% vs. 2.5%, odds ratio [95% CI]: 3.70 [0.77-17.6]; p = 0.10), the long-term mortality was significantly lower (24.2% vs. 50.1% at 8 years; hazard ratio [95% CI]: 0.48 [0.26-0.91]; p = 0.03) in the Redo-SAVR group. After inverse probability of treatment weighting analysis, Redo-SAVR remained significantly associated with reduced long-term mortality compared with ViV-TAVR (hazard ratio [95% CI]: 0.32 [0.22-0.46]; p < 0.001). CONCLUSIONS: ViV-TAVR was associated with a lower rate of intended hemodynamic performance and numerically lower mortality at 30 days but higher rates of long-term mortality compared with Redo-SAVR.