The relative area score for sublingual varices reliability measurement: a diagnostic study
BACKGROUND: Sublingual varices (SV) and their predictive potential for other clinical parameters is a much studied topic in oral medicine. SVs have been well studied as predictive markers for many common diseases such as arterial hypertension, cardiovascular disease, smoking, type 2 diabetes mellitu...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10242773/ https://www.ncbi.nlm.nih.gov/pubmed/37280604 http://dx.doi.org/10.1186/s12903-023-03068-x |
_version_ | 1785054291076055040 |
---|---|
author | Klein, Christian R. Stoppenbrink, David Geier, Jannik Mayr, Andreas Stark, Helmut |
author_facet | Klein, Christian R. Stoppenbrink, David Geier, Jannik Mayr, Andreas Stark, Helmut |
author_sort | Klein, Christian R. |
collection | PubMed |
description | BACKGROUND: Sublingual varices (SV) and their predictive potential for other clinical parameters is a much studied topic in oral medicine. SVs have been well studied as predictive markers for many common diseases such as arterial hypertension, cardiovascular disease, smoking, type 2 diabetes mellitus and age. Despite many prevalence studies, it is still unclear how the reliability of SV inspection affects its predictive power. The aim of this study was to quantify the inspection reliability of SV. METHODS: In a diagnostic study, the clinical inspection of 78 patients by 23 clinicians was examined for the diagnosis of SV. Digital images of the underside of the tongue were taken from each patient. The physicians were then asked to rate them for the presence of sublingual varices (0/1) in an online inspection experiment. Statistical analysis for inter-item and inter-rater reliability was performed in a τ-equivalent measurement model with Cronbach's [Formula: see text] and Fleiss κ. RESULTS: The interrater reliability for sublingual varices was relatively low with κ = 0.397. The internal consistency of image findings for SV was relatively high with α≈ 0.937. This shows that although SV inspection is possible in principle, it has a low reliability R. This means that the inspection finding (0/1) of individual images often cannot be reproduced stably. Therefore, SV inspection is a difficult task of clinical investigation. The reliability R of SV inspection also limits the maximum linear correlation [Formula: see text] of SV with an arbitrary other parameter Y. The reliability of SV inspection R = 0.847 limits the maximum correlation to [Formula: see text] (SV, Y) = 0,920—a 100% correlation was a priori not achievable in our sample. To overcome the problem of low reliability in SV inspection, we propose the RA (relative area) score as a continuous classification system for SV, which normalises the area of visible sublingual veins to the square of the length of the tongue, providing a dimensionless measure of SV. CONCLUSIONS: The reliability of the SV inspection is relatively low. This limits the maximum possible correlation of SV with other (clinical) parameters. SV inspection reliability is an important indicator for the quality of SV as a predictive marker. This should be taken into account when interpreting previous studies on SV and has implications for future studies. The RA score could help to objectify the SV examination and thus increase its reliability. |
format | Online Article Text |
id | pubmed-10242773 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-102427732023-06-07 The relative area score for sublingual varices reliability measurement: a diagnostic study Klein, Christian R. Stoppenbrink, David Geier, Jannik Mayr, Andreas Stark, Helmut BMC Oral Health Research BACKGROUND: Sublingual varices (SV) and their predictive potential for other clinical parameters is a much studied topic in oral medicine. SVs have been well studied as predictive markers for many common diseases such as arterial hypertension, cardiovascular disease, smoking, type 2 diabetes mellitus and age. Despite many prevalence studies, it is still unclear how the reliability of SV inspection affects its predictive power. The aim of this study was to quantify the inspection reliability of SV. METHODS: In a diagnostic study, the clinical inspection of 78 patients by 23 clinicians was examined for the diagnosis of SV. Digital images of the underside of the tongue were taken from each patient. The physicians were then asked to rate them for the presence of sublingual varices (0/1) in an online inspection experiment. Statistical analysis for inter-item and inter-rater reliability was performed in a τ-equivalent measurement model with Cronbach's [Formula: see text] and Fleiss κ. RESULTS: The interrater reliability for sublingual varices was relatively low with κ = 0.397. The internal consistency of image findings for SV was relatively high with α≈ 0.937. This shows that although SV inspection is possible in principle, it has a low reliability R. This means that the inspection finding (0/1) of individual images often cannot be reproduced stably. Therefore, SV inspection is a difficult task of clinical investigation. The reliability R of SV inspection also limits the maximum linear correlation [Formula: see text] of SV with an arbitrary other parameter Y. The reliability of SV inspection R = 0.847 limits the maximum correlation to [Formula: see text] (SV, Y) = 0,920—a 100% correlation was a priori not achievable in our sample. To overcome the problem of low reliability in SV inspection, we propose the RA (relative area) score as a continuous classification system for SV, which normalises the area of visible sublingual veins to the square of the length of the tongue, providing a dimensionless measure of SV. CONCLUSIONS: The reliability of the SV inspection is relatively low. This limits the maximum possible correlation of SV with other (clinical) parameters. SV inspection reliability is an important indicator for the quality of SV as a predictive marker. This should be taken into account when interpreting previous studies on SV and has implications for future studies. The RA score could help to objectify the SV examination and thus increase its reliability. BioMed Central 2023-06-06 /pmc/articles/PMC10242773/ /pubmed/37280604 http://dx.doi.org/10.1186/s12903-023-03068-x Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Klein, Christian R. Stoppenbrink, David Geier, Jannik Mayr, Andreas Stark, Helmut The relative area score for sublingual varices reliability measurement: a diagnostic study |
title | The relative area score for sublingual varices reliability measurement: a diagnostic study |
title_full | The relative area score for sublingual varices reliability measurement: a diagnostic study |
title_fullStr | The relative area score for sublingual varices reliability measurement: a diagnostic study |
title_full_unstemmed | The relative area score for sublingual varices reliability measurement: a diagnostic study |
title_short | The relative area score for sublingual varices reliability measurement: a diagnostic study |
title_sort | relative area score for sublingual varices reliability measurement: a diagnostic study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10242773/ https://www.ncbi.nlm.nih.gov/pubmed/37280604 http://dx.doi.org/10.1186/s12903-023-03068-x |
work_keys_str_mv | AT kleinchristianr therelativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT stoppenbrinkdavid therelativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT geierjannik therelativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT mayrandreas therelativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT starkhelmut therelativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT kleinchristianr relativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT stoppenbrinkdavid relativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT geierjannik relativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT mayrandreas relativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy AT starkhelmut relativeareascoreforsublingualvaricesreliabilitymeasurementadiagnosticstudy |