Cargando…
No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
BACKGROUND/AIMS: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. METHODS: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Gastrointestinal Endoscopy
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10244142/ https://www.ncbi.nlm.nih.gov/pubmed/37259242 http://dx.doi.org/10.5946/ce.2022.299 |
_version_ | 1785054570555113472 |
---|---|
author | Vedantam, Shyam Shah, Rahil Bhalla, Sean Kumar, Shria Amin, Sunil |
author_facet | Vedantam, Shyam Shah, Rahil Bhalla, Sean Kumar, Shria Amin, Sunil |
author_sort | Vedantam, Shyam |
collection | PubMed |
description | BACKGROUND/AIMS: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. METHODS: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. RESULTS: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%–95.2%) and 92.1% (95% CI, 68.4%–98.4%), clinical success rates of 88.6% (95% CI, 85.4%–91.1%) and 89.6% (95% CI, 79.0%–95.1%), adverse event rates of 11.4% (95% CI, 8.1%–15.9%) and 14.7% (95% CI, 4.4%–39.1%), and reintervention rates of 10.3% (95% CI, 6.7%–15.4%) and 3.5% (95% CI, 1.6%–7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40–9.18; p=0.008). CONCLUSIONS: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent. |
format | Online Article Text |
id | pubmed-10244142 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Korean Society of Gastrointestinal Endoscopy |
record_format | MEDLINE/PubMed |
spelling | pubmed-102441422023-06-08 No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis Vedantam, Shyam Shah, Rahil Bhalla, Sean Kumar, Shria Amin, Sunil Clin Endosc Systematic Review and Meta-analysis BACKGROUND/AIMS: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. METHODS: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. RESULTS: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%–95.2%) and 92.1% (95% CI, 68.4%–98.4%), clinical success rates of 88.6% (95% CI, 85.4%–91.1%) and 89.6% (95% CI, 79.0%–95.1%), adverse event rates of 11.4% (95% CI, 8.1%–15.9%) and 14.7% (95% CI, 4.4%–39.1%), and reintervention rates of 10.3% (95% CI, 6.7%–15.4%) and 3.5% (95% CI, 1.6%–7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40–9.18; p=0.008). CONCLUSIONS: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent. Korean Society of Gastrointestinal Endoscopy 2023-05 2023-05-22 /pmc/articles/PMC10244142/ /pubmed/37259242 http://dx.doi.org/10.5946/ce.2022.299 Text en Copyright © 2023 Korean Society of Gastrointestinal Endoscopy https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Systematic Review and Meta-analysis Vedantam, Shyam Shah, Rahil Bhalla, Sean Kumar, Shria Amin, Sunil No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
title | No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
title_full | No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
title_fullStr | No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
title_full_unstemmed | No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
title_short | No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
title_sort | no difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis |
topic | Systematic Review and Meta-analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10244142/ https://www.ncbi.nlm.nih.gov/pubmed/37259242 http://dx.doi.org/10.5946/ce.2022.299 |
work_keys_str_mv | AT vedantamshyam nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis AT shahrahil nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis AT bhallasean nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis AT kumarshria nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis AT aminsunil nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis |