Cargando…

No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis

BACKGROUND/AIMS: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. METHODS: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction...

Descripción completa

Detalles Bibliográficos
Autores principales: Vedantam, Shyam, Shah, Rahil, Bhalla, Sean, Kumar, Shria, Amin, Sunil
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Gastrointestinal Endoscopy 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10244142/
https://www.ncbi.nlm.nih.gov/pubmed/37259242
http://dx.doi.org/10.5946/ce.2022.299
_version_ 1785054570555113472
author Vedantam, Shyam
Shah, Rahil
Bhalla, Sean
Kumar, Shria
Amin, Sunil
author_facet Vedantam, Shyam
Shah, Rahil
Bhalla, Sean
Kumar, Shria
Amin, Sunil
author_sort Vedantam, Shyam
collection PubMed
description BACKGROUND/AIMS: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. METHODS: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. RESULTS: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%–95.2%) and 92.1% (95% CI, 68.4%–98.4%), clinical success rates of 88.6% (95% CI, 85.4%–91.1%) and 89.6% (95% CI, 79.0%–95.1%), adverse event rates of 11.4% (95% CI, 8.1%–15.9%) and 14.7% (95% CI, 4.4%–39.1%), and reintervention rates of 10.3% (95% CI, 6.7%–15.4%) and 3.5% (95% CI, 1.6%–7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40–9.18; p=0.008). CONCLUSIONS: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent.
format Online
Article
Text
id pubmed-10244142
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Korean Society of Gastrointestinal Endoscopy
record_format MEDLINE/PubMed
spelling pubmed-102441422023-06-08 No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis Vedantam, Shyam Shah, Rahil Bhalla, Sean Kumar, Shria Amin, Sunil Clin Endosc Systematic Review and Meta-analysis BACKGROUND/AIMS: We compared outcomes between use of 15 vs. 20 mm lumen-apposing metal stents (LAMSs) in endoscopic ultrasound-guided gastroenterostomy (EUS-GE) for gastric outlet obstruction. METHODS: Databases were queried for studies that used LAMS for EUS-GE to relieve gastric outlet obstruction, and a proportional meta-analysis was performed. RESULTS: Thirteen studies were included. The 15 mm and 20 mm LAMS had pooled technical success rates of 93.2% (95% confidence interval [CI], 90.5%–95.2%) and 92.1% (95% CI, 68.4%–98.4%), clinical success rates of 88.6% (95% CI, 85.4%–91.1%) and 89.6% (95% CI, 79.0%–95.1%), adverse event rates of 11.4% (95% CI, 8.1%–15.9%) and 14.7% (95% CI, 4.4%–39.1%), and reintervention rates of 10.3% (95% CI, 6.7%–15.4%) and 3.5% (95% CI, 1.6%–7.6%), respectively. Subgroup analysis revealed no significant differences in technical success, clinical success, or adverse event rates. An increased need for reintervention was noted in the 15 mm stent group (pooled odds ratio, 3.59; 95% CI, 1.40–9.18; p=0.008). CONCLUSIONS: No differences were observed in the technical, clinical, or adverse event rates between 15 and 20 mm LAMS use in EUS-GE. An increased need for reintervention is possible when using a 15 mm stent compared to when using a 20 mm stent. Korean Society of Gastrointestinal Endoscopy 2023-05 2023-05-22 /pmc/articles/PMC10244142/ /pubmed/37259242 http://dx.doi.org/10.5946/ce.2022.299 Text en Copyright © 2023 Korean Society of Gastrointestinal Endoscopy https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Systematic Review and Meta-analysis
Vedantam, Shyam
Shah, Rahil
Bhalla, Sean
Kumar, Shria
Amin, Sunil
No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
title No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
title_full No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
title_fullStr No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
title_full_unstemmed No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
title_short No difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
title_sort no difference in outcomes with 15 mm vs. 20 mm lumen-apposing metal stents for endoscopic ultrasound-guided gastroenterostomy for gastric outlet obstruction: a meta-analysis
topic Systematic Review and Meta-analysis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10244142/
https://www.ncbi.nlm.nih.gov/pubmed/37259242
http://dx.doi.org/10.5946/ce.2022.299
work_keys_str_mv AT vedantamshyam nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis
AT shahrahil nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis
AT bhallasean nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis
AT kumarshria nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis
AT aminsunil nodifferenceinoutcomeswith15mmvs20mmlumenapposingmetalstentsforendoscopicultrasoundguidedgastroenterostomyforgastricoutletobstructionametaanalysis