Cargando…
Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes
We present in detail the most known and commonly used methods for the calculation of electrode electroactive area ([Formula: see text] ) and heterogeneous electron transfer rate constants ([Formula: see text] ). The correct procedure for the calculation of these parameters is often disregarded due t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Vienna
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10244294/ https://www.ncbi.nlm.nih.gov/pubmed/37280450 http://dx.doi.org/10.1007/s00604-023-05832-w |
_version_ | 1785054606433189888 |
---|---|
author | Trachioti, Maria G. Lazanas, Alexandros Ch. Prodromidis, Mamas I. |
author_facet | Trachioti, Maria G. Lazanas, Alexandros Ch. Prodromidis, Mamas I. |
author_sort | Trachioti, Maria G. |
collection | PubMed |
description | We present in detail the most known and commonly used methods for the calculation of electrode electroactive area ([Formula: see text] ) and heterogeneous electron transfer rate constants ([Formula: see text] ). The correct procedure for the calculation of these parameters is often disregarded due to either lack of a minimum theoretical background or oversimplification of each method’s limitations and prerequisites. The aim of this work is to provide the theoretical background as well as a detailed guide for the implementation of these measurements by impressing upon the electrochemists the parameters that need to be considered so that the obtained results are safe and useful. Using graphite screen-printed electrodes, [Formula: see text] , and [Formula: see text] were calculated with different methods and techniques. Data are compared and discussed. GRAPHICAL ABSTRACT: [Image: see text] |
format | Online Article Text |
id | pubmed-10244294 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Vienna |
record_format | MEDLINE/PubMed |
spelling | pubmed-102442942023-06-08 Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes Trachioti, Maria G. Lazanas, Alexandros Ch. Prodromidis, Mamas I. Mikrochim Acta Original Paper We present in detail the most known and commonly used methods for the calculation of electrode electroactive area ([Formula: see text] ) and heterogeneous electron transfer rate constants ([Formula: see text] ). The correct procedure for the calculation of these parameters is often disregarded due to either lack of a minimum theoretical background or oversimplification of each method’s limitations and prerequisites. The aim of this work is to provide the theoretical background as well as a detailed guide for the implementation of these measurements by impressing upon the electrochemists the parameters that need to be considered so that the obtained results are safe and useful. Using graphite screen-printed electrodes, [Formula: see text] , and [Formula: see text] were calculated with different methods and techniques. Data are compared and discussed. GRAPHICAL ABSTRACT: [Image: see text] Springer Vienna 2023-06-07 2023 /pmc/articles/PMC10244294/ /pubmed/37280450 http://dx.doi.org/10.1007/s00604-023-05832-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Trachioti, Maria G. Lazanas, Alexandros Ch. Prodromidis, Mamas I. Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
title | Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
title_full | Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
title_fullStr | Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
title_full_unstemmed | Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
title_short | Shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
title_sort | shedding light on the calculation of electrode electroactive area and heterogeneous electron transfer rate constants at graphite screen-printed electrodes |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10244294/ https://www.ncbi.nlm.nih.gov/pubmed/37280450 http://dx.doi.org/10.1007/s00604-023-05832-w |
work_keys_str_mv | AT trachiotimariag sheddinglightonthecalculationofelectrodeelectroactiveareaandheterogeneouselectrontransferrateconstantsatgraphitescreenprintedelectrodes AT lazanasalexandrosch sheddinglightonthecalculationofelectrodeelectroactiveareaandheterogeneouselectrontransferrateconstantsatgraphitescreenprintedelectrodes AT prodromidismamasi sheddinglightonthecalculationofelectrodeelectroactiveareaandheterogeneouselectrontransferrateconstantsatgraphitescreenprintedelectrodes |