Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization

Background: The ultrathin-strut drug-eluting stent (DES) has shown better clinical results than thin- or thick-strut DES. We investigated if re-endothelialization was different among three types of DES: ultrathin-strut abluminal polymer-coated sirolimus-eluting stent (SES), thin-strut circumferentia...

Descripción completa

Detalles Bibliográficos
Autores principales: Hahn, Dongwoo, Lee, Donghoon, Hyun, Woonggyu, Cho, Yunnie, Yoon, Chang-Hwan, Jeon, Ki-Hyun, Kang, Si-Hyuck, Youn, Tae-Jin, Chae, In-Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10245535/
https://www.ncbi.nlm.nih.gov/pubmed/37292098
http://dx.doi.org/10.3389/fbioe.2023.1207858
_version_ 1785054882576728064
author Hahn, Dongwoo
Lee, Donghoon
Hyun, Woonggyu
Cho, Yunnie
Yoon, Chang-Hwan
Jeon, Ki-Hyun
Kang, Si-Hyuck
Youn, Tae-Jin
Chae, In-Ho
author_facet Hahn, Dongwoo
Lee, Donghoon
Hyun, Woonggyu
Cho, Yunnie
Yoon, Chang-Hwan
Jeon, Ki-Hyun
Kang, Si-Hyuck
Youn, Tae-Jin
Chae, In-Ho
author_sort Hahn, Dongwoo
collection PubMed
description Background: The ultrathin-strut drug-eluting stent (DES) has shown better clinical results than thin- or thick-strut DES. We investigated if re-endothelialization was different among three types of DES: ultrathin-strut abluminal polymer-coated sirolimus-eluting stent (SES), thin-strut circumferential polymer-coated everolimus-eluting stent (EES), and thick-strut polymer-free biolimus-eluting stent (BES) to gain insight into the effect of stent design on promoting vascular healing. Methods: After implanting three types of DES in the coronary arteries of minipigs, we performed optical coherence tomography (OCT) at weeks 2, 4, and 12 (n = 4, each). Afterward, we harvested the coronary arteries and performed immunofluorescence for endothelial cells (ECs), smooth muscle cells (SMCs), and nuclei. We obtained 3D stack images of the vessel wall and reconstructed the en face view of the inner lumen. We compared re-endothelialization and associated factors among the different types of stents at different time points. Results: SES showed significantly faster and denser re-endothelialization than EES and BES at weeks 2 and 12. Especially in week 2, SES elicited the fastest SMC coverage and greater neointimal cross-sectional area (CSA) compared to EES and BES. A strong correlation between re-endothelialization and SMC coverage was observed in week 2. However, the three stents did not show any difference at weeks 4 and 12 in SMC coverage and neointimal CSA. At weeks 2 and 4, SMC layer morphology showed a significant difference between stents. A sparse SMC layer was associated with denser re-endothelialization and was significantly higher in SES. Unlike the sparse SMC layer, the dense SMC layer did not promote re-endothelialization during the study period. Conclusion: Re-endothelialization after stent implantation was related to SMC coverage and SMC layer differentiation, which were faster in SES. Further investigation is needed to characterize the differences among the SMCs and explore methods for increasing the sparse SMC layer in order to improve stent design and enhance safety and efficacy.
format Online
Article
Text
id pubmed-10245535
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-102455352023-06-08 Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization Hahn, Dongwoo Lee, Donghoon Hyun, Woonggyu Cho, Yunnie Yoon, Chang-Hwan Jeon, Ki-Hyun Kang, Si-Hyuck Youn, Tae-Jin Chae, In-Ho Front Bioeng Biotechnol Bioengineering and Biotechnology Background: The ultrathin-strut drug-eluting stent (DES) has shown better clinical results than thin- or thick-strut DES. We investigated if re-endothelialization was different among three types of DES: ultrathin-strut abluminal polymer-coated sirolimus-eluting stent (SES), thin-strut circumferential polymer-coated everolimus-eluting stent (EES), and thick-strut polymer-free biolimus-eluting stent (BES) to gain insight into the effect of stent design on promoting vascular healing. Methods: After implanting three types of DES in the coronary arteries of minipigs, we performed optical coherence tomography (OCT) at weeks 2, 4, and 12 (n = 4, each). Afterward, we harvested the coronary arteries and performed immunofluorescence for endothelial cells (ECs), smooth muscle cells (SMCs), and nuclei. We obtained 3D stack images of the vessel wall and reconstructed the en face view of the inner lumen. We compared re-endothelialization and associated factors among the different types of stents at different time points. Results: SES showed significantly faster and denser re-endothelialization than EES and BES at weeks 2 and 12. Especially in week 2, SES elicited the fastest SMC coverage and greater neointimal cross-sectional area (CSA) compared to EES and BES. A strong correlation between re-endothelialization and SMC coverage was observed in week 2. However, the three stents did not show any difference at weeks 4 and 12 in SMC coverage and neointimal CSA. At weeks 2 and 4, SMC layer morphology showed a significant difference between stents. A sparse SMC layer was associated with denser re-endothelialization and was significantly higher in SES. Unlike the sparse SMC layer, the dense SMC layer did not promote re-endothelialization during the study period. Conclusion: Re-endothelialization after stent implantation was related to SMC coverage and SMC layer differentiation, which were faster in SES. Further investigation is needed to characterize the differences among the SMCs and explore methods for increasing the sparse SMC layer in order to improve stent design and enhance safety and efficacy. Frontiers Media S.A. 2023-05-23 /pmc/articles/PMC10245535/ /pubmed/37292098 http://dx.doi.org/10.3389/fbioe.2023.1207858 Text en Copyright © 2023 Hahn, Lee, Hyun, Cho, Yoon, Jeon, Kang, Youn and Chae. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Hahn, Dongwoo
Lee, Donghoon
Hyun, Woonggyu
Cho, Yunnie
Yoon, Chang-Hwan
Jeon, Ki-Hyun
Kang, Si-Hyuck
Youn, Tae-Jin
Chae, In-Ho
Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
title Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
title_full Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
title_fullStr Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
title_full_unstemmed Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
title_short Faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
title_sort faster smooth muscle cell coverage in ultrathin-strut drug-eluting stent leads to earlier re-endothelialization
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10245535/
https://www.ncbi.nlm.nih.gov/pubmed/37292098
http://dx.doi.org/10.3389/fbioe.2023.1207858
work_keys_str_mv AT hahndongwoo fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT leedonghoon fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT hyunwoonggyu fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT choyunnie fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT yoonchanghwan fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT jeonkihyun fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT kangsihyuck fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT yountaejin fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization
AT chaeinho fastersmoothmusclecellcoverageinultrathinstrutdrugelutingstentleadstoearlierreendothelialization